• Title/Summary/Keyword: Heating Condition

Search Result 1,304, Processing Time 0.028 seconds

Performance Characteristics of Anode-Supported Tubular Solid Oxide Fuel Cell (연료극 지지체식 원통형 고체산화물 연료전지의 성능 특성)

  • Song Rak-Hyun;Song Keun-Suk
    • Korean Journal of Materials Research
    • /
    • v.14 no.5
    • /
    • pp.368-373
    • /
    • 2004
  • To improve the conventional cathode-supported tubular solid oxide fuel cell (SOFC) from the viewpoint of low cell power density, expensive fabrication process and high operation temperature, the anode-supported tubular solid oxide fuel cell was investigated. The anode tube of Ni-8mol% $Y_2$O$_3$-stabilized $ZrO_2$ (8YSZ) was manufactured by extrusion process, and, the electrolyte of 8YSZ and the multi-layered cathode of $LaSrMnO_3$(LSM)ILSM-YSZ composite/$LaSrCoFeO_3$ were coated on the surface of the anode tube by slurry dip coating process, subsequently. Their cell performances were examined under gases of humidified hydrogen with 3% water and air. In the thermal cycle condition of heating and cooling rates with $3.33^{\circ}C$/min, the anode-supported tubular cell showed an excellent resistance as compared with the electrolyte-supported planar cell. The optimum hydrogen flow rate was evaluated and the air preheating increased the cell performance due to the increased gas temperature inside the cell. In long-term stability test, the single cell indicated a stable performance of 300 mA/$\textrm{cm}^2$ at 0.85 V for 255 hr.

Crack Healing Behavior with Healing Temperature in Si3N4/SiC Composite Ceramics (Si3N4/SiC 복합 세라믹의 온도에 따른 크랙 힐링 관찰과 확산거동)

  • Song, Oh-Sung;Ando, Kotoji;Takahashi, Koji;Nakao, Wataru;Ryu, Ji-Ho
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.780-785
    • /
    • 2005
  • To investigate the microcrack healing behavior of $Si_3N_4-20wt\%SiC-8wt\%Y_2O_3$ composite ceramics(SNCY8), we observe the crack length evolution a! the time of 20, 40, 60 minutes with in-situ optical microscopy by varying healing temperature of $800\~1200^{\circ}C$. Crack healing obviously occurred as heating temperature and time increased. We proposed a simple model of effective diffusion based on the crack length evolution with healing condition, and determined the effective diffusion coefficient as Our result implies that we may predict the healing ability quantitatively with temperature and time in structural ceramics through the effective diffusion coefficient model.

An Analysis on the Energy Consumption Unit of the Public buildings in Daegu (대구시 공공건축물의 에너지 소비 원단위에 관한 연구)

  • Choe, Jeong-Hui;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF

An Experimental Study of Precast concrete Alters Cement Types of High-Strength Concrete (시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 수화열 온도특성을 중심으로 -)

  • Park, Heung-Lee;Kim, Sung-Jin;Paik, Min-Su;Lee, Seung-Hoon;Park, Byung-Keun;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.119-122
    • /
    • 2009
  • As architectures have recently become high-risers and mega-structured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since not only external heating but a1so internal temperature rise caused by the accumulation of cement hydration heat in manufacturing process, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete fur precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated.

  • PDF

A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping (수면시 바닥표면온도에 따른 적정 환기량에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

Improvement and Standardization of Rural Korean Kitchen Space: Field Survey on Architectural Elements and Facilities(1) (농촌부엌의 개선 및 표준화에 관한 연구(I) -부엌의 물리적 측면을 중심으로-)

  • Chi, Soon;Yoon, Bocha;Yoon, Chung-Sook;Yoo, Young-Hee;Choi, Byoung-Sook
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.1
    • /
    • pp.71-96
    • /
    • 1991
  • The purpose of this study was to identify kitchen space needs in regard to the architectural elements and facilities of rural houses. Three rural villages, Kum-Sung Ri, Young-San 1 Ri, and Yu-Bang 2.5 Ri were selected for this study. The present and past condition of the kitchen space was investigated by the field survey method. The major findings were that: 1) The interior floor materials of the kitchen had been changed from mostly mudplastered floor to linoleum, and the former low level of the kitchen floor had been lifted to the same level of the house plane. This change was made possible by the separation of the cooking from the heating system. 2) Western style kitchen, work centers and kitchen cabinets had been installed in the most of the rural houses. 3) On the basis of this study, the rural Korean kitchen space was classified into six types.

  • PDF

Sorption behavior of slightly reduced, three-dimensionally macroporous graphene oxides for physical loading of oils and organic solvents

  • Park, Ho Seok;Kang, Sung Oong
    • Carbon letters
    • /
    • v.18
    • /
    • pp.24-29
    • /
    • 2016
  • High pollutant-loading capacities (up to 319 times its own weight) are achieved by three-dimensional (3D) macroporous, slightly reduced graphene oxide (srGO) sorbents, which are prepared through ice-templating and consecutive thermal reduction. The reduction of the srGO is readily controlled by heating time under a mild condition (at 1 10−2 Torr and 200℃). The saturated sorption capacity of the hydrophilic srGO sorbent (thermally reduced for 1 h) could not be improved further even though the samples were reduced for 10 h to achieve the hydrophobic surface. The large meso- and macroporosity of the srGO sorbent, which is achieved by removing the residual water and the hydroxyl groups, is crucial for achieving the enhanced capacity. In particular, a systematic study on absorption parameters indicates that the open porosity of the 3D srGO sorbents significantly contributes to the physical loading of oils and organic solvents on the hydrophilic surface. Therefore, this study provides insight into the absorption behavior of highly macroporous graphene-based macrostructures and hence paves the way to development of promising next-generation sorbents for removal of oils and organic solvent pollutants.

Indoor Environmental Condition by Existing Front Balcony in Apartment House during Winter (아파트의 전면발코니 개조여부에 따른 겨울철 실내환경 측정비교)

  • Choi, Yoon-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.267-270
    • /
    • 2005
  • The purpose of this study was to make clear the indoor environmental efficiency of front balcony 'in apartment houses during winter. The field measurements of indoor environmental elements were carried out at an ordinary house with an existing front balcony and a house renovated the front balcony into the living room. The measurements in two-subject houses were taken on simultaneously the 20$^{th}$ ${\sim}$ 21$^{th}$ of January 2003. As results, the averages indoor temperature in the ordinary house and the renovated house were same as 23.6${\circ}$C, and the averages globe temperature in two houses were same as 23.7${\circ}$C. But, estimated heating time of the renovated house was longer than that of the ordinary house. The daily ranges of indoor temperature and globe temperature in the renovated house were wider than the ordinary house. The daily ranges of indoor temperature and globe temperature in the renovated house was longer than that of the ordinary house. The uniformity ratio range of daylight in the ordinary house were calculated at 1/3.4${\sim}$1/6.2, but those of the renovated house were 1/6${\sim}$1/16.2. Therefore. it was found that indoor temperature, globe temperature and uniformity ratio of daylight in the ordinary house maintained more constant than the renovated house by green house effect and earning effect of front balcony.

  • PDF

The Static Collapse Characteristics of CFRP Single and Double Hat Shaped Section Members according to the Interface Number for Lightweight (경량화용 CFRP 단일 모자형 부재와 CFRP 이중 모자형 부재의 계면수 변화에 따른 정적압궤특성)

  • Hwang, Woo-Chae;Cha, Cheon-Seok;Yang, In-Young
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.20-25
    • /
    • 2012
  • Currently, the most important purpose in designing automobile is environment-friendly and safety performance aspect. CFRP(Carbon Fiber Reinforced Plastics) of the advanced composite materials as structure materials for vehicles, has a wide application in lightweight structural materials of air planes, ships and automobiles because of high strength and stiffness. In this study, experimental investigations are carried out for CFRP single and double hat shaped section member in order to study the effect of various stacking condition. They were cured by heating to the appropriate curing temperature($130^{\circ}C$) by means of a heater at the vacuum bag of the autoclave. The stacking conditions were selected to investigate the effect of the interface numbers. The CFRP single and double hat shaped section members which manufactured from unidirectional prepreg sheets were made of 8ply. The static collapse tests performed and the collapse mode and energy absorption capability were analyzed according to interface number.

The characterization for the Ti-silicide of $N^+P$ junction by 2 step RTD (2단계 RTD방법에 의한 $N^+P$ 접합 티타늄 실리사이드 특성연구)

  • 최도영;윤석범;오환술
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.737-743
    • /
    • 1995
  • Two step RTD(Rapid Thermal Diffussion) of P into silicon wafer using tungsten halogen lamp was used to fabricated very shallow n$^{+}$p junction. 1st RTD was performed in the temperature range of 800.deg. C for 60 see and the heating rate was in the 50.deg. C/sec. Phosphrous solid source was transfered on the silicon surface. 2nd RTD process was performed in the temperature range 1050.deg. C, 10sec. Using 2 step RTD we can obtain a shallow junction 0.13.mu.m in depth. After RTD, the Ti-silicide process was performed by the two step RTA(Rapid Thermal Annealing) to reduced the electric resistance and to improve the n$^{+}$p junction diode. The titanium thickness was 300.angs.. The condition of lst RTA process was 600.deg. C of 30sec and that of 2nd RTA process was varied in the range 700.deg. C, 750.deg. C, 800.deg. C for 10sec-60sec. After 2 step RTA, sheet resistance was 46.ohm../[]. Ti-silicide n+p junction diode was fabricated and I-V characteristics were measured.red.

  • PDF