• Title/Summary/Keyword: Health Device Profile(HDP)

Search Result 9, Processing Time 0.025 seconds

Transmitting/Receiving of Standard Health Data Using Bluetooth HDP on the Android Platform (안드로이드에서 블루투스 HDP를 이용한 표준건강정보의 송수신)

  • Park, Young-Jin;Cho, Hui-Sup;Son, Jong-Wuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.5
    • /
    • pp.464-470
    • /
    • 2013
  • These days, with increasing interest about the health care, research about standard for transmitting/receiving data of health device has been actively conducted. Standardization and testing / certification is underway through the IEEE 11073 PHD, Health Level Seven and the Continua Health Alliance, it'll continue to be more research and experiments in the future. In this paper, we introduce the IEEE 11073 PHD standards for exchange of remote health information and the Bluetooth Health Device Profile(HDP) for health device profile of the Bluetooth technology, also we conducted experiments about exchange health information between health device and smart device which are adapted the IEEE 11073 PHD and Bluetooth HDP. Transmitting/receiving of the IEEE 11073 PHD standard protocol using the Bluetooth HDP profile between health device and smart device can be known by this experiment, and it expect to implement variety of remote medical services through health device supporting these standards in future.

u-Healthcare Monitoring System Design using by Smartphone based on Bluetooth Health Device Profile (Bluetooth Health Device Profile기반 스마트폰을 이용한 u-Healthcare 모니터링 시스템 설계)

  • Cho, Kyoung-Lae;Kim, Sang-Yoon;Kim, Jung-Han;Oh, Am-Suk;Kim, Gwan-Hyung;Jean, Jae-Hwan;Kang, Sung-In
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1365-1369
    • /
    • 2013
  • Recently, the Personal Health Device(PHD) that measures various biometric data easily are highlighted for ensuring portability, scalability and interoperability among the device as well as needs for a standardization of managing information measured by. In this paper, we'd like to propose u-healthcare monitoring system that measure biometric data(Oxygen saturation, Body weight, ECG and Blood pressure) by PHD featured with transferring data into devices such as smartphone using Bluetooth Health Device Profile(HDP) based on the ISO/IEEE 11073.

A Design and Implementation of Mobile Healthcare System based on Smart Gateway (스마트 게이트웨이 기반 모바일 헬스케어시스템의 설계 및 구현)

  • Kang, Sung-In;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1970-1976
    • /
    • 2012
  • Home healthcare system has lot of things to do for the integration with medical instruments in the sense of standardization. We will design and implement mobile healthcare system based on smart gateway thru adaptation of ISO/IEEE 11073, and HL7 standard. And also we are willing to research heart rate monitor, pulse-oxygen meter and ECG monitor in order to develop mobile healthcare system for medical appliance. We studied the connection of standard medical devices, i.e, continua health alliance under the Android 4.x Bluetooth HDP(Health Device Profile) environments. We also tried to implement healthcare system which can support diagnosis for healthcare provider and user based on HL7 standard.

Development of device for cat healthcare monitoring using Smartphone

  • Nam, Heung Sik;Lee, Moon Joo;Kim, Geon A
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.157-163
    • /
    • 2022
  • In this paper, we propose to develop a Bluetooth Health Device Profile (HDP)-based smartphone system to utilize it for early detection of urinary tracts diseases that occur a lot in cats. Therefore, based on Bluetooth HDP, we developed a device and mobile application system (Mycatner®) that can monitor cat activity, toilet usage, urinary disease, and health status, and evaluated its availability to monitor cat health status. The specific feature of this system is that it can measure the number of cat urination frequencies to identify abnormal conditions suspected of urinary tract diseases early, and second, it can be tested with urine test paper and shared with animal hospitals, reducing time and cost. As a result, it is evaluated that the developed device capable of wireless monitoring the urinary system health status of cats is the first in our knowledge.

Implementation of ISO/IEEE 11073-10404 Monitoring System Based on U-Health Service (유헬스 서비스 기반의 ISO/IEEE 11073-10404 모니터링 시스템 구현)

  • Kim, Kyoung-Mok
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.6
    • /
    • pp.625-632
    • /
    • 2014
  • The u-health service is using portable device such as smart device and it consists of small computing device. The u-health service carry out same performance with desktop computer. We designed message structure based on Bluetooth HDP. This message structure is used to transmit patient's biometric data on the smart device of medical team, patient and family over the mobile network environment. ISO/IEEE 11073 PHD standard was defined based on the method of communication between the agent and the manager. And We are confirmed the reliable transmission of biometric data at the smart device by implementing the android OS based patient information monitoring application to check the status of patient for medical team, patient and family.

u-Healthcare Monitoring System Design using by Smartphone base on Bluetooth Health Device Profile (Bluetooth Health Device Profile기반 스마트폰을 이용한 u-Healthcare 모니터링 시스템 설계)

  • Cho, Kyoung-lae;Kim, Sang-yoon;Kim, Jung-han;Oh, Am-Suk;Jean, Jae Hwan;Kang, Sung-in
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.392-394
    • /
    • 2013
  • 최근 u-Healthcare 서비스에서 다양한 생체정보를 간편하게 측정하는 개인건강기기(PHD)와 측정된 정보를 전송하고 수집하기 위한 표준의 필요성이 제품 간의 이식성, 확장성, 상호 운영성을 보장하기 위해 크게 대두되고 있다. 개인건강기기에서 측정된 생체정보(산소포화도, 몸무게, 심전도, 혈압 등)를 ISO/IEEE 11073 기반인 Bluetooth Health Device Profile을 이용해서 스마트폰으로 실시간 모니터링 할 수 있는 시스템을 설계한다.

  • PDF

A Study on Oximetry System Based on ISO/IEEE 11073 using Smart-Phone (스마트폰을 활용한 ISO/IEEE 11073 기반의 산소포화도 측정에 관한 연구)

  • Kang, Seong-In
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1940-1946
    • /
    • 2013
  • The Object of smart healthcare service is focused on preventive healthcare and wellness; It also aims for the user oriented active service. Recently, Smart healthcare using smart-phone can support various services like basal physical fitness, caloric intake, checking heartbeat and so on. However, it has not yet commercially viable service model because of incomplete personal health devices standardization. We designed and implemented Android smart healthcare Manager to support ISO/IEEE 11073 by Bluetooth HDP using oximetry System.

Design of Smart TV-based Smart Healthcare Solution for Healthcare Service (헬스케어 서비스를 위한 스마트 TV 기반 스마트 헬스케어 솔루션 설계)

  • Heo, Sung-Uk;Kang, Sung-In;Kim, Gwan-Hyung;Choi, Sung-Wook;Jeon, Jae-Hwan;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.361-363
    • /
    • 2013
  • 본 논문에서는 최근 스마트 헬스케어가 보건의료서비스에 특화시켜 환자와 의사가 직 간접적으로 진료를 할 수 있게끔 하는 스마트폰 환경에서의 원격진료 서비스가 부각됨에 따라 유무선 통신 인프라를 기반으로 노인, 만성질환자, 회복중인 환자나 수술 후 환자 그리고 일반인 등이 일상생활을 하면서 불편하거나, 거추장스럽지 않게 신체 정보를 측정하고 건강상태의 변화에 대한 전문가의 진단을 즉각적으로 제공하기 위해 Bluetooth HDP(Health Device Profile)을 통해 IEEE11073 PHD 표준 기반의 홈 헬스케어 의료기기 연결성을 보장하며, HL7 CDA 기반의 정보 전달 구조로 의료진뿐만 아니라 다양한 스마트 앱 어플리케이션 간의 융합을 가능하게 하는 스마트 헬스케어 솔루션을 설계하고자 한다.

  • PDF

Implementation of Service Model to Exchange of Biosignal Information based on HL7 Fast Health Interoperability Resources for the hypertensive management (고혈압 관리를 위한 헬스레벨 7 FHIR 기반 생체정보 교환 서비스 모델 구현)

  • Cho, Hune;Won, Ju Ok;Hong, Hae Sook;Kim, Hwa Sun
    • Journal of Internet Computing and Services
    • /
    • v.15 no.3
    • /
    • pp.21-30
    • /
    • 2014
  • Hypertension is one of the major causes of death in the world as it is related with cardiovascular or cerebrovascular disease, so it is needed to provide continuos management for blood pressure. This study selected Health Level 7 Fast Health Interoperability Resources (HL7 FHIR) as a bio-signal data exchange service model that can provide constant blood pressure management in the rapidly growing mobile health care environment. The HL7 FHIR framework developed communicates with the IEEE 11073-10407 Personal Health Device (PHD) protocol through the bluetooth Health Device Profile (HDP) between the manager (smart phone) and the agent (hemomanometer) and acquires information about blood pressure. According to the test results, it performed its tasks successfully including hypertension patients' blood pressure monitoring, management on measured records, generation of document, or transmission of measured information. Because in the actual, clinical environment, it is possible to transmit measured information through the TCP/IP protocol, it will be needed to conduct constant research on it and vitalize it in the field of mobile health care afterwards.