DOI QR코드

DOI QR Code

A Study on Oximetry System Based on ISO/IEEE 11073 using Smart-Phone

스마트폰을 활용한 ISO/IEEE 11073 기반의 산소포화도 측정에 관한 연구

  • Kang, Seong-In (Department of Biomedical Engineering, Tongmyong University)
  • Received : 2013.06.17
  • Accepted : 2013.08.05
  • Published : 2013.08.31

Abstract

The Object of smart healthcare service is focused on preventive healthcare and wellness; It also aims for the user oriented active service. Recently, Smart healthcare using smart-phone can support various services like basal physical fitness, caloric intake, checking heartbeat and so on. However, it has not yet commercially viable service model because of incomplete personal health devices standardization. We designed and implemented Android smart healthcare Manager to support ISO/IEEE 11073 by Bluetooth HDP using oximetry System.

스마트 헬스케어 서비스(smart healthcare service)는 예방적 건강관리와 웰니스(wellness)를 위한 수요자 중심의 능동적 서비스 제공을 목표로 한다. 최근, 스마트 헬스케어는 스마트폰을 사용하여 기초체력 운동 지수, 섭취 칼로리, 심박 체크 등의 다양한 서비스를 제공할 수 있다. 그러나 미비한 개인건강기기 표준화로 아직까지 상용 가능한 서비스 모델이 없는 실정이다. 이에 본 논문에서는 산소포화도 측정계를 사용하여 Bluetooth HDP를 기반으로 ISO/IEEE 11073 표준을 지원하는 안드로이드 스마트 헬스케어 Manager를 설계, 구현하였다.

Keywords

References

  1. C.Y. Park, J.H. Lim, S.J. Park, S.H. Kim, "Technical Trend of U-Healthcare Standardization," Electronics and Telecommunications Research Institute, Electronics and Telecommunications Trends , vol. 25, no 4, pp. 48-59, 2010. 8.
  2. Hui-jeong Hwang, "Reference Model of u-Health service", 2010 Semina for u-Health Standard Patents and the activating plans, 2010.7.
  3. Song Taemin, "Present Status and policy tasks of u-Health", Korea Institute for Health and Social Affairs, 2011. 1.
  4. Yeong-jae Chang, Gang-hae Lee, "Trend of Test Certification Technologies in Continua", Telecommunications Technology Association(TTA) , TTA Journal, vol. 135, 2011.
  5. Continua Health Alliance Available: http://www.contin uaalliance.org
  6. D. P. Bogia, "ISO/IEEE 11073 Personal Health Devices Tutorial," IEEE, 2010.
  7. Sung-in Kang, Am-suk Oh, "A Design and Implement of Mobile Healthcare System based on Smart Gateway", Journal of the Korea Institute of Information and Communication Engineering, vol. 16, no. 9, pp. 1970-1976, 2012. 9 https://doi.org/10.6109/jkiice.2012.16.9.1970
  8. Kevin Hendrix, "Health Device Profile WhitePaper Version 1.0", SYBASE, INC., July 2009
  9. NONIN Medical, $Onyx(R)$ II 9560 Pulse Oximeter, Available: http://www.nonin.com/PulseOximetry/Fingertip /Onyx9560.

Cited by

  1. Development of Cell Phone Application for Blood Glucose Self-Monitoring Based on ISO/IEEE 11073 and HL7 CCD vol.21, pp.2, 2015, https://doi.org/10.4258/hir.2015.21.2.83
  2. 유헬스 서비스 기반의 ISO/IEEE 11073-10404 모니터링 시스템 구현 vol.18, pp.6, 2013, https://doi.org/10.12673/jant.2014.18.6.625