DOI QR코드

DOI QR Code

Implementation of ISO/IEEE 11073-10404 Monitoring System Based on U-Health Service

유헬스 서비스 기반의 ISO/IEEE 11073-10404 모니터링 시스템 구현

  • Kim, Kyoung-Mok (Department of Medical Information system, Shamyook University College)
  • 김경목 (삼육보건대학교 의료정보시스템과)
  • Received : 2014.11.17
  • Accepted : 2014.12.16
  • Published : 2014.12.30

Abstract

The u-health service is using portable device such as smart device and it consists of small computing device. The u-health service carry out same performance with desktop computer. We designed message structure based on Bluetooth HDP. This message structure is used to transmit patient's biometric data on the smart device of medical team, patient and family over the mobile network environment. ISO/IEEE 11073 PHD standard was defined based on the method of communication between the agent and the manager. And We are confirmed the reliable transmission of biometric data at the smart device by implementing the android OS based patient information monitoring application to check the status of patient for medical team, patient and family.

유헬스 서비스는 사물인터넷 장치와 스마트 기기와 같은 모바일 장치를 사용하기 때문에 휴대가 간편한 소형 컴퓨팅 장치로 구성되어 있으며, 기존 컴퓨터에서 수행하던 작업을 동시에 수행할 수 있다. 환자의 생체정보를 이동통신망 환경에서 의료진과 환자 및 환자의 가족의 스마트기기로 실시간으로 전달할 수 있도록 bluetooth HDP기반의 메시지 구조를 사용하였다. ISO/IEEE 11073 PHD 표준을 기반으로 agent와 manager 사이의 통신 방법을 정의하였다. 의료진과 환자 및 환자의 가족이 스마트 기기를 통하여 실시간으로 확인할 수 있도록 안드로이드 기반의 모니터링 애플리케이션을 구현하여 일상생활에서 사용되고 있는 스마트 기기에서 동작을 확인함으로써 생체정보의 원활한 송수신을 확인하였다.

Keywords

References

  1. I. H. Jo and D. H. Kim, Growth and opportunity for smart healthcare market, Issue crunch, KT Economic Management Research Institute, pp. 1-12, 2013.
  2. B. K. Lee, Key to open the smart healthcare market, Mobile healthcare device, Digiecho Report, KT Economic Management Research Institute, pp. 1-10, 2014.
  3. Health informatics-personal health device communication-part 20601 : Application profile-optimized exchange protocol, ISO/IEEE 11073-20601, April 2010.
  4. Guideline for verification of IEEE 11073 personal health device standards, TTAK.KO.10.478, Telecommunications Technology Association, June 2012.
  5. Health informatics-personal health device communication-part 10404: device specialization-pulse oximeter, ISO/IEEE 11073-10404, June 2010.
  6. Personal health device communication-pulse oximeter, TTAK.KO-10.0568, Telecommunications Technology Association, June 2012.
  7. S. I. Kang, "A study on oximetry system based on ISO/IEEE 11073 using smart-phone," Journal of the Korea Institute of Information and Communication Engineering, Vol. 17, No. 8, pp. 1940-1946, Aug. 2013. https://doi.org/10.6109/jkiice.2013.17.8.1940
  8. J. H. Jeon, A design and implementation of smart healthcare system based on ISO/IEEE 11073 and HL7, Ph.D. Dissertation, Tongmyong University Graduate School, Busan, Korea, 2013.
  9. U-health service reference model, TTAK.KO-10.0463/R1, Telecommunications Technology Association, April 2014.
  10. S. I. Kang and A. S. Oh, "A design and implementation of mobile healthcare system based on smart gateway", Journal of the Korea Institute of Information and Communication Engineering, Vol. 16, No. 9, pp. 1970-1976, Sep. 2012. https://doi.org/10.6109/jkiice.2012.16.9.1970

Cited by

  1. 유-헬스 앱 개발을 위한 센서 추상화: 정확도 향상을 위한 필터링 및 요약 vol.19, pp.5, 2014, https://doi.org/10.12673/jant.2015.19.5.446
  2. A Study on Foresight the Promising Technology in IoT-based U-Health Industry vol.3, pp.4, 2014, https://doi.org/10.33443/tm.2018.3.4.99