• 제목/요약/키워드: Head stud

검색결과 19건 처리시간 0.021초

Ultrasonic Phased Array Techniques for Detection of Flaws of Stud Bolts in Nuclear Power Plants

  • Lee, Joon-Hyun;Choi, Sang-Woo
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.440-446
    • /
    • 2006
  • The reactor vessel body and closure head are fastened with the stud bolt that is one of crucial parts for safety of the reactor vessels in nuclear power plants. It is reported that the stud bolt is often experienced by fatigue cracks initiated at threads. Stud bolts are inspected by the ultrasonic technique during the overhaul periodically for the prevention of failure which leads to radioactive leakage from the nuclear reactor. The conventional ultrasonic inspection for stud bolts was mainly conducted by reflected echo method based on shadow effect. However, in this technique, there were numerous spurious signals reflected from every oblique surfaces of the thread. In this study, ultrasonic phased array technique was applied to investigate detectability of flaws in stud bolts and characteristics of ultrasonic images corresponding to different scanning methods, that is, sector and linear scan. For this purpose, simplified stud bolt specimens with artificial defects of various depths were prepared.

Ultrasonic Inspection of Cracks in Stud Bolts of Reactor Vessels in Nuclear Power Plants by Signal Processing of Differential Operation

  • Choi, Sang-Woo;Lee, Joon-Hyun;Oh, Won-Deok
    • 비파괴검사학회지
    • /
    • 제25권6호
    • /
    • pp.439-445
    • /
    • 2005
  • The stud bolt is one of crucial parts for safe operation of reactor vessels in nuclear power plants, Crack initiation and propagation were reported in stud bolts that arc used for closure of reactor vessel and head, Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure which could induce radioactive leakage from nuclear reactor, In conventional ultrasonic testing for inspection of stud bolts, cracks are detected by using shadow effect It takes too much time to inspect stud bolts by using conventional ultrasonic technique. In addition, there were numerous spurious signals reflected from every oblique surfaces of thread, In this study, the signal processing technique for enhancing conventional ultrasonic technique was introduced for inspecting stud bolts. The signal processing technique provides removing spurious signal reflected from every oblique surfaces of thread and enhances detectability of defects. Detectability for small crack was enhanced by using this signal processing in ultrasonic inspection of stud bolts in Nuclear Power Plants.

Experimental investigation of shear connector behaviour in composite beams with metal decking

  • Qureshi, Jawed;Lam, Dennis
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.475-494
    • /
    • 2020
  • Presented are experimental results from 24 full-scale push test specimens to study the behaviour of composite beams with trapezoidal profiled sheeting laid transverse to the beam axis. The tests use a single-sided horizontal push test setup and are divided into two series. First series contained shear loading only and the second had normal load besides shear load. Four parameters are studied: the effect of wire mesh position and number of its layers, placing a reinforcing bar at the bottom flange of the deck, normal load and its position, and shear stud layout. The results indicate that positioning mesh on top of the deck flange or 30 mm from top of the concrete slab does not affect the stud's strength and ductility. Thus, existing industry practice of locating the mesh at a nominal cover from top of the concrete slab and Eurocode 4 requirement of placing mesh 30 mm below the stud's head are both acceptable. Double mesh layer resulted in 17% increase in stud strength for push tests with single stud per rib. Placing a T16 bar at the bottom of the deck rib did not affect shear stud behaviour. The normal load resulted in 40% and 23% increase in stud strength for single and double studs per rib. Use of studs only in the middle three ribs out of five increased the strength by 23% compared to the layout with studs in first four ribs. Eurocode 4 and Johnson and Yuan equations predicted well the stud strength for single stud/rib tests without normal load, with estimations within 10% of the characteristic experimental load. These equations highly under-estimated the stud capacity, by about 40-50%, for tests with normal load. AISC 360-16 generally over-estimated the stud capacity, except for single stud/rib push tests with normal load. Nellinger equations precisely predicted the stud resistance for push tests with normal load, with ratio of experimental over predicted load as 0.99 and coefficient of variation of about 8%. But, Nellinger method over-estimated the stud capacity by about 20% in push tests with single studs without normal load.

Reliability Evaluations for Shear Strength of Resistance Welded Ball Stud according to Different Cooling Methods

  • Park, In-Duck;Nam, Ki-Woo
    • 동력기계공학회지
    • /
    • 제22권6호
    • /
    • pp.44-50
    • /
    • 2018
  • As a type of bolt with a spherical head, the ball stud is widely used as a part of a ball joint in steering or suspension systems in automobiles. Balls and studs are subjected to heat treatment suitable for each material; in particular, the shear strength of the ball stud must meet the specifications of the production company. This study evaluated the shear strength of joints according to the cooling method of ball studs subject to resistance welding. The shear stress of water cooling was higher than that of air cooling (as-received material). Note, however, th at oil cooling showed lower stress than that of as-received. When judged by standard deviation, mean, and coefficient of variation according to the arithmetic statistics and shape parameter as well as scale parameter, oil cooling is suitable.

임피턴스헤드로 진동계측시 변환기의 부착영향을 보상하는 방법에 관한 연구 (A Study on the Compensation of Transducer Effects for the Measurement of Vibration with an Impedance Head)

  • 이현엽;박재영
    • 소음진동
    • /
    • 제5권1호
    • /
    • pp.117-122
    • /
    • 1995
  • The transfer matrix method is proposed to compensate the attachment effect of a piezo-electric impedance head. To validate the proposed method, an experiment is carried out for axial vibration of a uniform rod for which an analytical solution is known. The impedance head is attached to the test rod by a stud and is connected to the exciter. The frequency response function is mesured by applying random excitation from the electro-magnetic exciter. The frequency response function compensated by the method proposed in this research shows good agreement with the analytical solution.

  • PDF

인장력을 받는 RC 부재와 철골 부재 접합부의 유한요소해석 (Finite Element Analysis of Connections between RC and Steel Member under Tensile Loading)

  • 김은주;김승훈;서수연;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.75-82
    • /
    • 2001
  • Finite element analysis using ANSYS program conducted to evaluate the tensile behavior of the connection between reinforced concrete and steel members is presented in this paper. It is assumed that there is a complete bond between head part of the stud and concrete. However, the surface of the column area of stud is separated from the concrete to stop the stress transmission between those. In case of using reinforcement connectors such as C or U type, the interface between concrete and reinforcement is idealized to have strong adhesion. Four concrete-steel specimens which are connected by stud connector or reinforcement connectors are compared and analyzed From the comparison, it was shown that the connection between concrete and steel could be predicted by using the modeling technique used in this paper.

  • PDF

초고성능 콘크리트 바닥판을 위한 스터드 전단연결재의 정적 거동 (Static Behavior of Stud Shear Connector for UHPC Deck)

  • 이경찬;곽종원;박상혁;김지상
    • 콘크리트학회논문집
    • /
    • 제26권5호
    • /
    • pp.573-579
    • /
    • 2014
  • 합성보는 콘크리트 바닥판과 강재 거더로 이루어져 왔으나, 바닥판의 자중을 줄이면서 내구성을 향상시키고 나아가 교량의 강도 및 강성을 향상시키기 위하여 초고성능 콘크리트(UHPC)를 교량 바닥판으로 채용한 합성보가 최근에 제안되고 있다. 이 연구는 기존의 스터드 전단연결재가 UHPC 바닥판을 합성함에 있어 유효한지에 관하여 실험적으로 검토해보고자 한다. 12개의 push-out 시험체를 통하여 UHPC 바닥판에 매립된 스터드 전단연결재의 정적 강도를 평가하였으며, 실험 변수로 바닥판 두께, 스터드 높이 및 지름을 채택하여, 기존에 제한되었던 스터드 지름에 대한 높이의 비율인 형상비와 스터드 머리부 상부 콘크리트 피복두께의 제한을 완화하는 것이 가능한지에 대하여 검토하였다. 이 연구의 실험으로부터 기존 AASHTO LRFD에 제시된 정적 강도평가식을 UHPC에 매립된 스터드 전단연결재에 적용하는 것이 유효함을 확인하였으며, 4이상으로 제한된 형상비는 3.1까지 낮추어도 되며, 50 mm로 제한된 최소 피복두께도 25 mm까지 낮출수 있음을 확인하였다. 다만 Eurocode-4에 제시된 연성도 기준인 특성 상대슬립 6 mm 이상의 기준을 만족하지 못하여, UHPC에 매립된 스터드 전단연결재는 별도의 연성 보강 방안이 채택되지 않는다면 강성 전단연결재로 간주하여야 할 것이다.

Ultimate strength of composite structure with different degrees of shear connection

  • Kim, Sang-Hyo;Jung, Chi-Young;Ahn, Jin-Hee
    • Steel and Composite Structures
    • /
    • 제11권5호
    • /
    • pp.375-390
    • /
    • 2011
  • Composite beam, which combined the material characteristic of the steel and concrete, has been widely used in the construction of various building and bridge system. For the effective application of the composite beam, the composite action on the composite interface between the concrete element and the steel element should be achieved by shear connectors. The behavioral characteristics of composite beam are related with the degree of interaction and the degree of shear connection according to the shear strength and shear stiffness of the stud shear connectors. These two concepts are also affected by the number of installed shear connector and the strength of composite materials. In this study, experimental and analytical evaluations of the degree of shear connection affected by stud diameter were conducted, and the relationship between structural behavior and the degree of shear connection was verified. The very small difference among the ultimate loads of the specimens depending on the change of the degree of connection was possibly because of the dependence of the ultimate load on the characteristic of plastic moment of the composite beam.

강합성 교량의 콘크리트 바닥판 해체 및 재시공이 용이한 분리식 볼트접합 전단연결재에 관한 실험적 연구 (An Experimental Study of Demountable Bolted Shear Connectors for the Easy Dismantling and Reconstruction of Concrete Slabs of Steel-Concrete Composite Bridges)

  • 정대성;박세현;김태형;김철영
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.751-762
    • /
    • 2022
  • 강합성 교량에서 강 거더와 콘크리트 바닥판의 합성을 위한 전단연결재로는 용접접합 머리붙이 스터드가 주로 사용된다. 용접접합 전단연결재의 경우, 손상 또는 노후화된 바닥판 철거 시에 파쇄에 따른 소음, 비산먼지 등이 발생하여 환경적 문제가 지적되고 있다. 따라서 환경적 문제 및 생애주기비용 관점의 효율적인 유지관리를 위해서는 노후화된 콘크리트 바닥판의 교체가 용이한 분리식 전단연결재 개발이 필요하다. 기존의 볼트접합 전단연결재로는 매립너트 방식이 주로 연구되었으나 낮은 강성과 전단저항강도, 초기슬립 증가 등으로 교량과 같은 토목구조물에는 활용되지 못하고 있는 실정이다. 본 논문에서는 이러한 문제점들을 개선하기 위해 매립너트 부분이 스터드 기둥에 일체화되고 확대 기둥 하단에 테이퍼진 형상을 갖는 분리식 볼트접합 전단연결재를 제안하였다. 제안된 분리식 스터드볼트의 정적 전단강도와 슬립 변위에 대한 성능 검증을 위해 수평전단실험을 수행하였고, 기존 용접접합 스터드와 성능을 비교하였다. 제안된 분리식 볼트접합 전단연결재가 전단성능이 매우 우수하고, 슬립변위 또한 연성설계기준을 만족함으로써 기존 용접 스터드를 충분히 대체하여 적용 가능함을 확인하였다.

원위치파쇄기층화 공법의 개발 및 실용화 연구 (Development and Practical Use of Rubblization Method)

  • 고석범;김경택;이영철;이승우
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.405-416
    • /
    • 2005
  • The rubblization technique is breaking the aged concrete pavement slab into rubblized concrete aggregate, and use it as an base material at its original position, then builds overlay above the rubblized base. This method has been successively used in USA due to the advantage of good contructibility, cost-effectiveness as well as the capability of preventing of reflection cracks. However, constructibility and economic performance of rubblization on typical Korean concrete pavements needed to be investigate since to typical Korean concrete pavements have thick slab, as well include lean concrete subbase course. This stud explored optimum breaking depth and suggested minimum 10cm based on reflection crack simulation test. Also proper head shape and impact energy were investigated based on small breaking field tests. It was found that $127kg/cm^2$ of stress with 52.3% of head contact area are breaking requirement. Also, Multi-head type breaker suitable for Korean condition was designed and developed. This multi-head type breaker was designed to rubblize old concrete to the suggested optimum rubblized-depth and rubblized-concrete-aggregate size to prevent reflection crack and maintain high bearing capacity. This machine was used for the test of rubblization of old concrete pavement on a non-use old concrete and a in-serviced road. In these two tests, engineering properties of rubblized base and constructability and cost were investigated. In both tests, the old concrete rubblized to targeted size and depth, and high-level bearing capacity was achieved. Also, superior constructability and lower cost compared with traditional reconstruction was examined.

  • PDF