DOI QR코드

DOI QR Code

An Experimental Study of Demountable Bolted Shear Connectors for the Easy Dismantling and Reconstruction of Concrete Slabs of Steel-Concrete Composite Bridges

강합성 교량의 콘크리트 바닥판 해체 및 재시공이 용이한 분리식 볼트접합 전단연결재에 관한 실험적 연구

  • 정대성 (국토교통연구인프라운영원) ;
  • 박세현 (국토교통연구인프라운영원) ;
  • 김태형 (국토교통연구인프라운영원) ;
  • 김철영 (명지대학교 토목.환경공학과)
  • Received : 2022.04.11
  • Accepted : 2022.08.25
  • Published : 2022.12.01

Abstract

Welded head studs are mainly used as shear connectors to bond steel girders and concrete slabs in steel-concrete composite bridges. For welded shear connectors, environmental problems include noise and scattering dust which are generated during the removal of damaged or aged slabs. Therefore, it is necessary to develop demountable shear connectors that can easily replace aged concrete slabs for efficient maintenance and thus for better management of environmental problems and life cycle costs. The buried nut method is commonly studied in relation to bolted shear connectors, but this method is not used in civil structures such as bridges due to low rigidity, low shear resistance, and increased initial slip. In this study, in order to mitigate these problems, a demountable bolted shear connector is proposed in which the buried nut is integrated into the stud column and has a tapered shape at the bottom of an enlarged column shank. To verify the performance of the proposed demountable stud bolts in terms of static shear strength and slip displacement, a horizontal shear test was conducted, with the performance outcomes compared to those of conventional welded studs. It was confirmed that the proposed demountable bolted shear connector is capable of excellent shear performance and that it satisfies the slip displacement and ductility design criteria, meaning that it is feasible as a replacement for existing welding studs.

강합성 교량에서 강 거더와 콘크리트 바닥판의 합성을 위한 전단연결재로는 용접접합 머리붙이 스터드가 주로 사용된다. 용접접합 전단연결재의 경우, 손상 또는 노후화된 바닥판 철거 시에 파쇄에 따른 소음, 비산먼지 등이 발생하여 환경적 문제가 지적되고 있다. 따라서 환경적 문제 및 생애주기비용 관점의 효율적인 유지관리를 위해서는 노후화된 콘크리트 바닥판의 교체가 용이한 분리식 전단연결재 개발이 필요하다. 기존의 볼트접합 전단연결재로는 매립너트 방식이 주로 연구되었으나 낮은 강성과 전단저항강도, 초기슬립 증가 등으로 교량과 같은 토목구조물에는 활용되지 못하고 있는 실정이다. 본 논문에서는 이러한 문제점들을 개선하기 위해 매립너트 부분이 스터드 기둥에 일체화되고 확대 기둥 하단에 테이퍼진 형상을 갖는 분리식 볼트접합 전단연결재를 제안하였다. 제안된 분리식 스터드볼트의 정적 전단강도와 슬립 변위에 대한 성능 검증을 위해 수평전단실험을 수행하였고, 기존 용접접합 스터드와 성능을 비교하였다. 제안된 분리식 볼트접합 전단연결재가 전단성능이 매우 우수하고, 슬립변위 또한 연성설계기준을 만족함으로써 기존 용접 스터드를 충분히 대체하여 적용 가능함을 확인하였다.

Keywords

Acknowledgement

이 연구는 국토교통부 국토교통기술촉진연구사업의 연구비지원(22CTAP-C164073-02)에 의해 수행되었습니다. 이에 감사드립니다.

References

  1. AASHTO LRFD. (2007). Bridge design specifications, 4th ed., AASHTO, Washington, DC, USA.
  2. Ahn, J. H., Choi, K. T., Kim, S. H. and Kim, S. H. (2008). "Shear capacity of corrugated rib shear connector." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 28, No. 3A, pp. 375-381 (in Korean).
  3. Cho, S. K., Lee, J. M., Youn, S. G. and Choi, Y. W. (2008). "Behavior of stud shear connectors in precast deck using lightweight concrete." Journal of Korean Society of Steel Construction, Vol. 20, No. 2, pp. 227-236 (in Korean).
  4. Chung, C. H. and Lee, H. S. (2005). "Evaluation of shear strength of the ㄱ-type Perfobond rib shear connectors." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 25, No. 5A, pp. 879-888 (in Korean).
  5. Chung, C. H., Lee, H. S., You, S. K. and Choi, W. H. (2005a). "Experimental analysis of ㄱ-type Perfobond rib shear connection between steel tubes and concrete deck." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 25, No. 1A, pp. 201-212 (in Korean).
  6. Chung, C. H., Kim, J. S., Park, H. S. and Joo, B. C. (2005b). "Strength of bolt type shear connector in precast deck composite bridges." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 25, No. 5A, pp. 787-800 (in Korean).
  7. Csillag, F. and Pavlovic, M. S. (2021). "Push-out behaviour of demountable injected vs. blind-bolted connectors in FRP decks." Composite Structures, Vol. 270, 114043.
  8. EN 1994-1-1. (2004). Eurocode-4: Design of composite steel and concrete structures, CEN, Brussels, Belgium.
  9. Hawkins, N. M. (1987). "Strength in shear and tension of cast-in-place anchor bolts." Anchorage to Concrete SP-103, Vol. 103, pp. 233-256.
  10. Jung, D. S., Park, S. H., Kim, T. H., Han, J. W. and Kim, C. Y. (2022). "Demountable bolted shear connector for easy deconstruction and reconstruction of concrete slabs in steel-concrete bridges." Applied Sciences, Vol. 12, No. 3, 1508. DOI: https://doi.org/10.3390/app12031508.
  11. KDS 14 31 10. (2017). Design standard of structural steel members (LRFD), Korea Construction Standards Center, Goyang-si, Korea.
  12. Kim, H. Y. and Koo, H. B. (2006). "Composite behavior of Perfobond rib shear connector for steel-concrete decks." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 26, No. 1A, pp. 91-97 (in Korean).
  13. Kwon, G. U. (2008). Strengthening existing steel bridge girders by the use of post-installed shear connectors, Ph.D. Thesis, The University of Texas, Austin, TX, USA.
  14. Lam, D., Dai, X. and Saveri, E. (2013). "Behaviour of demountable shear connectors in steel-concrete composite beams." International Conference on Composite Construction in Steel and Concrete VII, ASCE, pp. 613-631.
  15. Lee, P. G., Shim, C. S. and Yoon, T. Y. (2003). "Static behavior of large stud shear connectors." Journal of Korean Society of Steel Construction, Vol. 15, No. 6, pp. 611-620 (in Korean).
  16. Loqman, N., Safiee, N. A., Bakar, N. A. and Nasir, N. A. M. (2018). "Structural behavior of steel-concrete composite beam using bolted shear connectors: A review." MATEC Web of Conferences 203, 06010.
  17. Marshall, W. T., Nelson, H. M. and Banarjee, H. K. (1971). "An experimental study of the use of high strength friction-grip bolts as shear connectors in composite beams." Structural Engineer, Vol. 49, pp. 171-178.
  18. Nguyen, H. T. and Kim, S. E. (2009). "Finite element modeling of push-out tests for large stud shear connectors." Journal of Constructional Steel Research, Vol. 65, No. 10-11, pp. 1909-1920. https://doi.org/10.1016/j.jcsr.2009.06.010
  19. Pavlovic, M. S. (2013). Resistance of bolted shear connectors in prefabricated steel-concrete composite decks, Ph.D. Thesis, University of Belgrade, Republic of Serbia.
  20. Shim, C. S. (2004). "Experiments on limits state design of large stud shear connectors." KSCE Journal of Civil Engineering, KSCE, Vol. 8, No. 3, pp. 313-318. https://doi.org/10.1007/BF02836013