• Title/Summary/Keyword: Head rotation

Search Result 342, Processing Time 0.032 seconds

The System for 3D Image Obtain and Provide corresponding to User's Viewpoint (사용자 시점에 대응 3차원 영상 획득 및 제공 시스템)

  • Lee, Seung-Jae;Jeon, Yeong-Mi;Kim, Nam-Woo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.835-837
    • /
    • 2016
  • In this research, Detect viewpoint of the user in other to obtain the coordinates and provided obtain a corresponding stereo images of different positions, Provide a system which can be observed remotely break the spatial limits. For system configuration Designed with a physical action such as left and right movement and rotation of the head is the largest factor in human viewpoint change. Therefore, this system is calculated to analyze user viewpoint, Control system for providing three-dimensional images obtained, It is implemented in network communication for data transmission, As the user observed the object in the same space even though free to observe a target at a remote location, Obtaining a stereo image that corresponds to the viewpoint providing a three-dimensional image, We implemented a system that provides the same visual effect and directly observed.

  • PDF

A Study on a Mask R-CNN-Based Diagnostic System Measuring DDH Angles on Ultrasound Scans (다중 트레이닝 기법을 이용한 MASK R-CNN의 초음파 DDH 각도 측정 진단 시스템 연구)

  • Hwang, Seok-Min;Lee, Si-Wook;Lee, Jong-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.183-194
    • /
    • 2020
  • Recently, the number of hip dysplasia (DDH) that occurs during infant and child growth has been increasing. DDH should be detected and treated as early as possible because it hinders infant growth and causes many other side effects In this study, two modelling techniques were used for multiple training techniques. Based on the results after the first transformation, the training was designed to be possible even with a small amount of data. The vertical flip, rotation, width and height shift functions were used to improve the efficiency of the model. Adam optimization was applied for parameter learning with the learning parameter initially set at 2.0 x 10e-4. Training was stopped when the validation loss was at the minimum. respectively A novel image overlay system using 3D laser scanner and a non-rigid registration method is implemented and its accuracy is evaluated. By using the proposed system, we successfully related the preoperative images with an open organ in the operating room

Correlation Analysis between Kinematic Variables and Ground Slope Perception Ability during Golf Putting (골프 퍼팅 시 운동학적 변인과 경사도 인지능력 간 상관성 분석)

  • Lee, Jae-Woo;Im, Young-Tae;Kwon, Moon-Seok;Park, Jun-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.727-734
    • /
    • 2021
  • The purpose of this study was to analyze correlation between kinematic variables and ground slope perception ability during golf putting. 16 collegiate golfers were participated. To collect and analyze the kinematic data of putter head, SAMPutt lab was used(70 Hz). It was performed Pearson's correlation analysis using SPSS. The level of significance was at .05. As a results, right was correlated with backswing in flat. Toe-up was correlated with follow-through and left was correlated with aim, backswing, impact, follow-through, and loft in slice 1°. Toe-down was correlated with aim, backswing, impact in slice 2°. Toe-up was correlated with follow-through in hook 2°. In conclusion, it is important to improve the putting stroke through repetitive ground slope perception training.

Effect Analysis of Pulley on Performance of Micro Hydropower in Free Surface Vortex (자유수면 와류에서 마이크로 소수력의 성능에 풀리가 미치는 영향 분석)

  • Choi, In-Ho;Kim, Jong-Woo;Chung, Gi-Soo
    • Journal of Wetlands Research
    • /
    • v.23 no.3
    • /
    • pp.234-241
    • /
    • 2021
  • This paper contributes to the understanding of the effect of pulley on the performance of the vortex turbine in free water surface. The experimental work was to analyze the rotation, voltage and current of the turbine due to physical factors (vortex height, velocity, effective head, etc.) at flow rates ranging from 0.0069 to 0.0077 m3/s in the inlet channel. As a result, the experimental values showed that voltage, current and rotational speed of the vortex turbine decreased with increasing the pulley ratio regardless of the blade type. The efficiency of straight blade and twisted blade was 52 % at the gear ratio of 0.45, whereas the efficiency of small twisted blade was 54 % at the pulley ratio of 0.21. The highest amount of the energy generated by the water free vortex turbine occurred within a pulley ratio of 0.5. The efficiency of this vortex turbine was observed at 0.2 ~ 58 % depending on the pulley ratio.

Correlations between the Clinical and Ultrasonographic Parameters of Congenital Muscular Torticollis without a Sternocleidomastoid Mass

  • Jisun Hwang;Eun Kyung Khil;Soo Jin Jung;Jung-Ah Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1374-1382
    • /
    • 2020
  • Objective: To determine whether ultrasonography at initial presentation can help assess the clinical severity of congenital muscular torticollis (CMT) in infants without a sternocleidomastoid muscle (SCM) mass. Materials and Methods: This retrospective study included 71 infants aged less than 12 months (4.1 ± 2.3 months) with non-mass CMT. The clinical severity was divided into three grades (groups 1-3) based on the degree of lateral head bending or cervical rotation. The difference (SCM-D) and ratio (SCM-R) between the maximal thickness of the affected and non-affected SCMs were obtained using transverse and longitudinal ultrasonography. The sonographic echotexture and echogenicity of the involved SCM were reviewed. Results: A significant difference was observed in the SCM-D (0.42 ± 0.30 mm in group 1; 0.74 ± 0.50 mm in group 2; 1.14 ± 0.85 mm in group 3; p = 0.002) and SCM-R (1.069 ± 0.067 in group 1; 1.129 ± 0.087 in group 2; 1.204 ± 0.150 in group 3; p = 0.001) among the groups when measured along the longitudinal but not along the transverse ultrasonography plane. The areas under the curves of the SCM-R and SCM-D measured by longitudinal ultrasonography were 0.731 (p < 0.001) and 0.731 (p < 0.001) for group 1 versus groups 2-3. The proportions of heterogeneous echotexture or hyperechogenicity in the involved SCM did not differ significantly among the three clinical groups (all p > 0.05). Conclusion: Ultrasonography can aid in assessing the clinical severity of CMT in infants without an SCM mass at the time of initial diagnosis. The SCM-R and SCM-D helped grade the clinical severity when obtained by longitudinal scan.

Effects of Elastic Band-Resistive Exercise using Audio-visual Medium on Pain, Proprioceptive Sense, and Motor Function in Adult Females with Chronic Neck and Shoulder Pain (만성 목-어깨 통증이 있는 여성 성인에게 시청각 매체를 활용한 탄력밴드 저항운동이 통증, 고유수용성 감각과 운동기능에 미치는 영향)

  • Nam Gi Lee;Jeong-Woo Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.33-45
    • /
    • 2024
  • Background: This study aimed to investigate the effect of elastic band-resistive exercise using audio-visual medium on pain, proprioception, and motor function in adults with chronic neck and shoulder pain. Design: One group pretest-posttest follow-up experimental design. Method: Twenty adult women with neck and shoulder pain voluntarily participated in this study. Elastic band-resistive exercise using audio-visual medium including cervical flexion and extension, shoulder external rotation, and scapular retraction-protraction motions was conducted 5 times a week for 3 weeks. The Numerical Rating Scale, pressure threshold tool, CROM goniometer, and Image J software were used to assess subjective pain level, tenderness threshold (pain), joint position sense error (proprioception), joint range of motion, and postural alignment (motor function), respectively. Result:: The pain intensity and threshold and joint position sense error showed significant decreases after the intervention, whereas the joint range of motion angle revealed significant increases. The postural alignment including forward head posture and rounded shoulder revealed significant improvements after the intervention. Conclusions: Therefore, we suggest that elastic band-resistive exercise through audio-visual medium would be helpful in preventing and managing pain and physical dysfunction in individuals with chronic neck and shoulder pain, and then it would support the development of health management-related online education content.

Total Hip Arthroplasty in Protrusio Acetabuli: A Systematic Review

  • Sajid Ansari;Kshitij Gupta;Tushar Gupta;Balgovind S. Raja;Pranav J.;Roop Bhushan Kalia
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.12-25
    • /
    • 2024
  • Protrusio acetabuli, or abnormal protrusion of the femoral head into the acetabulum, requires performance of a total hip arthroplasty (THA) for which various reconstruction techniques and outcomes have been described. The aim of this systematic review is to provide a comprehensive analysis of the current evidence, evaluate treatment efficacy, compare surgical techniques, and identify topics for future research along with improving evidence-based decision-making, improving patient outcomes in the management of this condition. A thorough systematic review of the PubMed, Embase, Cochrane Library databases, and Scopus library was conducted, and articles describing techniques of THA for treatment of protrusion acetabuli were extracted. The initial search generated 751 results. After exclusion, 18 articles were included. Of these, eight were prospective studies and 10 were retrospective. Surgery was performed on 783 hips with a mean age of 60 years; 80% of females who mostly had inflammatory arthritis were followed up for 8.86 years (range, 2-15.4 years). Good outcomes have been achieved with THA using uncemented cups with bone graft; however, no conclusion could be drawn with regard to the femoral side. It can be concluded that the concept of restoration of the anatomical hip center of rotation is paramount for good outcome and better survival of the implant is important when using uncemented cups with a bone graft. In addition, screw augmentation for fixation is not recommended unless absolutely necessary. The most common complications were aseptic loosening and heterotopic ossification. While the former required revision, conservative management was administered for the latter.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

'Hwawang': A Good Quality and Early-Maturing Rice Variety Adaptable for Rice-Cash Crop Rotation System (소득작물 후작용 고품질 조생 벼품종 '화왕')

  • Lee, Jong-Hee;Lee, Ji-Yoon;Yeo, Un-Sang;Song, You-Chun;Park, Dong-Soo;Hwang, Un-Hwa;Park, Soo-Gwan;Park, No-Bong;Kim, Sang-Yeol;Oh, Seong-Hwan;Han, Sang-Ik;Nam, Min-Hee;Lee, Jong-Gi;Cho, Jun-Hyeon
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.534-539
    • /
    • 2018
  • 'Hwawang' is an early maturing and short statured rice cultivar adaptable to the rice-cash crop rotation system that was developed by the rice breeding team of the Department of Southern Crop, National Institute of Crop Science (NICS), Rural Development Administration (RDA), Korea, in 2012. This cultivar was derived from the cross of YR25867 (Hitomebore//YR21247-B-B-B-49-1/Sasanishiki BL4) and YR25866 (Akidagomachi//YR21247-B-B-B-49-1/Sasanishiki BL4) during the 2005/2006 winter season and was fixed as a homozygous line by a doubled haploid breeding system. In the replicated yield trial in 2009, a promising line (YR26253Acp26-1) showed a good phenotype and high yield potential, and so it was selected and designated as 'Milyang256'. The local adaptability test of 'Milyang256' was carried out at three locations from 2010 to 2012. It was named 'Hwawang' and had a high head rice ratio and good eating quality. The culm length of 'Hwawang' averaged 62 cm during the yield trials and was 10 cm shorter than that of 'Keumo'. The number of spikelets per panicle of 'Hwawang' was significantly lower than that of 'Keumo', but the number of tillers per hill was higher. This variety showed resistance to bacterial blight disease but was moderately susceptible to both leaf and neck blast. The milled rice yield of 'Hwawang' was 452 kg/10 a at the late transplanting stage of the local adaptability test. Thus, 'Hwawang' is well adapted to the rice-cash crop rotation system in the southern plain area. (Registration No. 5106)