• 제목/요약/키워드: Hardened concrete

검색결과 569건 처리시간 0.021초

감수제의 고형분율 변화에 따른 모르타르의 기초적 특성 (Fundamental Characteristics of Mortar According to the Changes in the Solid Content Rate of the Water-Reducing Agent)

  • 김민상;이재진;현승용;김태우;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.156-157
    • /
    • 2017
  • It is possible in the case of the chemical admixtures for concrete currently being used in actual work sites to omit quality evaluation and replace it with the scores of the admixture manufactures; this can create a problem of decline in reliability in quality on the work site. Therefore this study sought to analyze the degree of influence changes in the solid content rate of lignin- and naphthalene-based water-reducing agents have on the fundamental characteristics of cement mortar. The results showed that in fresh mortar, the flow and amount of air decreases with decrease in the solid content ratio. In hardened mortar, the condensation strength had hardly any effect on the use of lignin-based water-reducing agent, but naphthalene-based water-reducing agent increased with the decrease in the solid content ratio.

  • PDF

방수재료 및 공법의 내구성 평가를 위한 복합열화분석용 3차원 거동대응 시험결과 (A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results)

  • 송제영;서현재;최은규;이정훈;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.189-190
    • /
    • 2018
  • KS standards mostly relate to single component material evaluation, so in cases of underground structure environments, most cannot predict the existing composite forms of deterioration, resulting in the applied waterproofing materials becoming unable to respond to these damaging factors. Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material.

  • PDF

High temperature resistance of self-compacting lightweight mortar incorporating expanded perlite and pumice

  • Karatas, Mehmet;Balun, Bilal;Benli, Ahmet
    • Computers and Concrete
    • /
    • 제19권2호
    • /
    • pp.121-126
    • /
    • 2017
  • This paper presents the effect of aggregate type on high temperature resistance of self-compacting mortars (SCM) produced with normal and lightweight aggregates like expanded perlite and pumice. Silica fume (SF) and fly ash (FA) were used as mineral additives. Totally 13 different mixtures were designed according to the aggregate rates. Mini slump flow, mini V-funnel and viscometer tests were carried out on the fresh mortar. On the other hand, bulk density, porosity, water absorption and high temperature tests were made on the hardened SCM. After being heated to temperatures of 300, 600 and $900^{\circ}C$, respectively, the tensile strength in bending and compressive strength of mortars determined. As a result of the experiments, the increase in the use of lightweight aggregate increased total water absorption and porosity of mortars. It is observed that, the increment in the usage of lightweight aggregate decreased tensile strength in bending and compressive strengths of mortar specimens exposed to high temperatures but the usage of up to 10% expanded perlite in mortar increased the compressive strength of specimens exposed to $300^{\circ}C$.

Relations between rheological and mechanical properties of fiber reinforced mortar

  • Cao, Mingli;Li, Li;Xu, Ling
    • Computers and Concrete
    • /
    • 제20권4호
    • /
    • pp.449-459
    • /
    • 2017
  • Fresh and hardened behaviors of a new hybrid fiber (steel fiber, polyvinyl alcohol fiber and calcium carbonate whisker) reinforced cementitious composites (HyFRCC) with admixtures (fly ash, silica fume and water reducer) have been studied. Within the limitations of the equipment and testing program, it is illustrated that the rheological properties of the new HyFRCC conform to the modified Bingham model. The relations between flow spread and yield stress as well as flow rate and plastic viscosity both conform well with negative exponent correlation, justifying that slump flow and flow rate test can be applied to replace the other two as simple rheology measurement and control method in jobsite. In addition, for the new HyFRCC with fly ash and water reducer, the mathematical model between the rheological and mechanical properties conform well with the quadratic function, and these quadratic function curves are always concave upward. Based on mathematical analysis, an optimal range of rheology/ flowability can be identified to achieve ideal mechanical properties. In addition, this optimization method can be extended to PVA fiber reinforced cement-based composites.

Effect of low-calcium fly ash on sulfate resistance of cement paste under different exposure conditions

  • Zhang, Wuman;Zhang, Yingchen;Gao, Longxin
    • Advances in concrete construction
    • /
    • 제7권3호
    • /
    • pp.175-181
    • /
    • 2019
  • Low-calcium fly ash (LCFA) were used to prepare cement/LCFA specimens in this study. The basic physical properties including water demand, fluidity, setting time, soundness and drying shrinkage of cement/LCFA paste were investigated. The effects of curing time, immersion time and wet-dry cycles in 3% $Na_2SO_4$ solution on the compressive strength and the microstructures of specimens were also discussed. The results show that LCFA increases the water demand, setting time, soundness of cement paste samples. 50% and 60% LCFA replacement ratio decrease the drying shrinkage of hardened cement paste. The compressive strength of plain cement specimens decreases at the later immersion stage in 3% $Na_2SO_4$ solution. The addition of LCFA can decrease this strength reduction of cement specimens. For all specimens with LCFA, the compressive strength increases with increasing immersion time. During the wet-dry cycles, the compressive strength of plain cement specimens decreases with increasing wet-dry cycles. However, the pores in the specimens with 30% and 40% LCFA at early ages could be large enough for the crystal of sodium sulfate, which leads to the compressive strength increase with the increase of wet-dry cycles in 3% $Na_2SO_4$ solution. The microstructures of cement/LCFA specimens are in good agreement with the compressive strength.

Correlation study on microstructure and mechanical properties of rice husk ash-Sodium aluminate geopolymer pastes

  • Singh, N. Shyamananda;Thokchom, Suresh;Debbarma, Rama
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.73-80
    • /
    • 2021
  • Rice Husk Ash (RHA) geopolymer paste activated by sodium aluminate were characterized by X-ray diffractogram (XRD), scanning electron microscope (SEM), energy dispersion X-Ray analysis (EDAX)and fourier transform infrared spectroscopy (FTIR). Five series of RHA geopolymer specimens were prepared by varying the Si/Al ratio as 1.5, 2.0, 2.5, 3.0 and 3.5. The paper focuses on the correlation of microstructure with hardened state parameters like bulk density, apparent porosity, sorptivity, water absorption and compressive strength. XRD analysis peaks indicates quartz, cristobalite and gibbsite for raw RHA and new peaks corresponding to Zeolite A in geopolymer specimens. In general, SEM micrographs show interconnected pores and loosely packed geopolymer matrix except for specimens made with Si/Al of 2.0 which exhibited comparatively better matrix. Incorporation of Al from sodium aluminate were confirmed with the stretching and bending vibration of Si-O-Si and O-Si-O observations from the FTIR analysis of geopolymer specimen. The dense microstructure of SA2.0 correlate into better performance in terms of 28 days maximum compressive strength of 16.96 MPa and minimum for porosity, absorption and sorptivity among the specimens. However, due to the higher water demand to make the paste workable, the value of porosity, absorption and sorptivity were reportedly higher as compared with other geopolymer systems. Correlation regression equations were proposed to validate the interrelation between physical parameters and mechanical strength. RHA geopolymer shows comparatively lower compressive strength as compared to Fly ash geopolymer.

Numerical modelling of effective thermal conductivity of hardened cement paste

  • Cheng Liu;Qiang Liu;Jianming Gao;Yunsheng Zhang
    • Computers and Concrete
    • /
    • 제32권6호
    • /
    • pp.567-576
    • /
    • 2023
  • In this study, a 3D microstructure-based model is established to simulate the effective thermal conductivity of cement paste, covering varying influencing factors associated with microstructure and thermal transfer mechanisms. The virtual cement paste divided into colloidal C-S-H and heterogeneous paste are reconstructed based on its structural attributes. Using the two-level hierarchical cement pastes as inputs, a lattice Boltzmann model for heat conduction is presented to predict the thermal conductivity. The results suggest that due to the Knudsen effect induced by the nanoscale pore, the thermal conductivity of air in C-S-H gel pore is significantly decreased, maximumly accounting for 3.3% thermal conductivity of air at the macroscale. In the cement paste, the thermal conductivities of dried and saturated cement pastes are stable at the curing age larger than 100 h. The high water-to-cement ratio can decrease the thermal conductivity of cement paste.

Effect of surface treatment on mechanical and micro-structural properties of basalt fiber reinforced mortars

  • Sukru Ozkan
    • Computers and Concrete
    • /
    • 제34권2호
    • /
    • pp.195-212
    • /
    • 2024
  • The use of basalt fibers in various types of fiber-reinforced mortars has been increasing. One of the factors that expands the use of basalt fibers is that it is a natural fiber and therefore the production costs are lower than fibers such as PVA fiber. Basalt fibers have some drawbacks such as reducing the workability of mortars in which basalt fibers are added due to their structure, and negatively affecting the mechanical properties when used above a certain proportional amount depending on the type of mixture. For this purpose, in this study, as a different application, the surface of basalt fibers with different lengths (6 and 12 mm) was treated with Triton X-100 surfactant, and these disadvantages were tried to be reduced. In the study, a two-step method was followed. In the first one, the effectiveness of adding untreated and treated basalt fiber at 1, 1.25, 1.5, 1.75 and 2% by weight to the mortar mixtures was determined by conducting flow spread and flow rate as fresh mortar characteristics. In the second one, microstructural characterization and mechanical tests were performed as hardened mortar properties. The results showed that the flow characteristics of basalt fiber reinforced mortars treated with surfactant improved compared to untreated basalt fiber reinforced mortars. In terms of mechanical properties, the addition of 2% treated basalt fiber by weight to the mixtures allowed to obtain %18, %12, and%48 higher values of compressive, flexural, and tensile strength values, respectively, compared to the same amount of untreated basalt fiber mixtures.

히팅슬립폼을 적용한 수직구 구조물의 상승속도에 관한 연구 (A study on the slip-up speed of a shaft using heating slip form)

  • 고엄식;이상훈;박종필;지광습;김창용
    • 한국터널지하공간학회 논문집
    • /
    • 제21권6호
    • /
    • pp.811-823
    • /
    • 2019
  • 최근에는 수직구 구조물 시공방법으로 현장타설 공법 대비 시공속도가 빠르며, 안전하고 경제적인 연속상승 슬립폼 공법이 다수의 현장에 적용되고 있다. 슬립폼 공법으로 시공 가능한 높이는 2.5~4 m/day로 알려져 있는데, 콘크리트 온도가 10~30℃의 범위 밖에서는 강도 변화나 탄성 특성의 변화에 미치는 영향이 크므로 동절기 공사에서는 3 m/day 이상의 시공속도를 내기가 어렵다. 또한, 콘크리트는 수화 작용으로 인해 수화열이 발생하는데, 이는 콘크리트의 온도 균열을 초래한다. 따라서 슬립폼 연속상승시 콘크리트의 온도 제어 양생이 필요하며, 본 연구에서는 히팅 패널 및 시험용 연속상승 장치를 개발하여 반발경도, 초음파 전파시간, 수화열 및 외부온도를 측정하였다. 이를 기반으로 히팅슬립폼을 제작하였으며, "김포 현장"과 "신월 현장"에 히팅슬립폼을 적용하였다. 김포현장은 주간(08:00~17:30) 평균 1.9 m/day 또는 0.200 m/hr, 신월 현장은 2.0 m/day 또는 0.210 m/hr를 목표 상승속도 값으로 비교하였다.

골재크기와 배합비에 따른 플라이애시 콘크리트의 투기특성 분석 (Analysis of Permeability Characteristics for Fly Ash Concrete According to Aggregate Size and Mixing Ratio)

  • 서은아;김도겸;정철우;이호재
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.400-406
    • /
    • 2023
  • 이 연구에서는 재료의 물성과 투기특성과의 관계를 검토하였으며 투기특성을 분석하기 위한 실험방법을 제시하고 실험결과를 도출하였다. 경화된 콘크리트의 압축강도와 겉보기 밀도가 투기특성에 미치는 영향에 대해서 실험적 방법으로 평가하였다. 원전 콘크리트 구조물에 사용된 배합을 중심으로 결합재, 최대 골재 치수, 물-결합재 비의 변화에 따라 콘크리트 시험체를 제작하고 투기특성을 측정했다. 겉보기 밀도는 OPC 배합과 FA-35 배합이 2,400 kg/m3 이상 나타났으며, 두 배합의 기체 투기량이 0.1 ~ 0.2 L/min 의 범위로 낮게 나타났다. 반면, FA-40와 FA-45 및 FA-M 배합의 경우 겉보기 밀도는 2,400 kg/m3 이하 투기량은 0.3 L/min 이상으로 측정되어 겉보기 밀도가 투기특성에 중요한 인자임을 실험적으로 검증하였다.