• Title/Summary/Keyword: Hank's solution

Search Result 34, Processing Time 0.026 seconds

Effect of In-Vitro Fertilization of Porcine Matured Oocytes in Different IVM-IVC Culture Media on the Development of the Embryos (미성숙 돼지 난자가 다른 체외성숙.배양에 의한 배 발달률에 미치는 영향)

  • 안미현;홍대욱;석호봉
    • Journal of Embryo Transfer
    • /
    • v.18 no.3
    • /
    • pp.269-274
    • /
    • 2003
  • This experiment was carried out to investigate the effects of different IVM-IVC culture media factors, such as development rates according to the maturation media, collecting times from slaughter to initiation of incubation and with cumulus cells, on in vitro maturation of oocytes collected from 3∼5mm diameter follicles of the swine abattoir The development rates significantly(p<0.05) higher when the oocytes were matured TCM-199 media than NCSU-23 media. In comparing with TCM199 medium in presence of Earle's salts and Hank's salt, there were no significantly differences between each salt balance in cleaved rate and in number of morulae plus blastocyst. Among 1,455 immature oocytes, 999(68.6%) of oocytes were cleaved. The number of development to the morulae and blastocysts were 617(61.8%) include 62 balstocysts(6.2%).

Wear Properties of Biocompatible Ti Implant due to Nitrogen Ion Implantation (질소이온주입에 따른 생체안전성 티타늄 임플란트의 마모특성)

  • 최종운;손선희;변응선;정용수
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.126-134
    • /
    • 1999
  • In this study, plasma source ion implantation was used to improve the wear properties of biocompatible titanium implant. In order to observe the effect of ion energy and dose on wear property of titanium implant, pin-on-disk type wear tests in Hank's solution were carried out. The friction coefficient of ion implanted specimens were increased from 0.47 to 0.65 under high energy and ion dose conditions. As increasing ion energy and ion dose, the amount of wear was reduced.

  • PDF

Effect of Nitrogen Ion Implantation on Corrosion Resistance of Biocompatible Ti Implant (질소이온의 주입이 생체안전성 티타늄임플란트의 내식성에 미치는 영향)

  • 최종운;손선희
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.134-139
    • /
    • 1999
  • In this study, PSII(plasma source ion implantation) was used to improve the biocompatibility of bone-anchored Ti implant. According to potentiodynamic anodic polarization test in deaerated Hank's solution, open circuit potential of ion implanted specimens were increased compare to that of unimplanted specimen ; besides, passive current density and critical anodic current density of ion implanted specimens were lower than unimplanted specimen.

  • PDF

Integrated characterization of the corrosion products of Mg alloy (마그네슘 합금 부식 산화물에 대한 특성 연구)

  • Gwon, Sang-Jun;Heo, Jin-Yeong;Lee, Hong-Gi
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.179-180
    • /
    • 2015
  • pure Mg and some Mg alloys are relatively rapidly corroded after operation, resulting in the decrease of mechanical strength and change of local ion concentration. In this study, the corrosion mechanism of biodegradable implant materials was investigated by corrosion tests of the Mg alloy in Hank's solution. Particularly, the crystal structures and chemical bonding state of corrosion reactants was systematically examined.

  • PDF

The Corrosiveness Evaluation according to the Needle Material in the Electroacupuncture Operation (전침 시술시 침 재료에 따른 부식성 평가)

  • Kwon, O-Sang;Choi, Kwang-Ho;Cho, Sung-Jin;Ryu, Yeon-Hee;Choi, Sun-Mi;Lee, Sang-Hoon
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives : Electroacupuncture is widely used because of its diverse curative influence. However, its electrical safety is not guaranteed when applied on the human body. Therefore, in this study, we did research on the corrosiveness of electroacupuncture when applied on the body fluid. Methods : We did research using acupuncture needles which were made of STS304 or STS316 and which were coated or not coated in silicone. They were 0.25 mm in diameter and 40 mm in length. We immersed them to the depth of about 1cm in Hank's Solution and gave a stimulus in 120 Hz for 60 minutes. Then, we measured the pH of Hank's solution and mass of needles and observed their shape. Results : Acupuncture needles which were made of STS304 corroded more easily than those which were made of STS316 when they were applied on the human body. Acupuncture needles which were coated in silicone corroded much more easily than those which were not coated in silicone when they were applied on the body fluid. Conclusions : In this study, we did research on the corrosiveness of electroacupuncture when it is applied on the body fluid using several acupuncture needles. We made a conclusion that when acupuncture needles were applied on the body fluid, the coated one made of STS304 corrodes more easily than the uncoated one made of STS316. We hope that additional further researches on the effect of the corrosiveness of an acupuncture needle will be carried out.

Comparative study on survival rate of human gingival fibroblasts stored in different storage media (수종의 저장용액에서의 치은섬유모세포 생존율의 비교연구)

  • Lee, Hee Su;Lim, You Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.4
    • /
    • pp.733-739
    • /
    • 2012
  • Objectives : To Compare the degree of survival rate of gingival fibroblasts, which is concerned with teeth adherence based on the type of avulsed tooth's storage solution. Methods : Different media gingival fibroblasts were stored in Dulbecco's modified Eagle's medium(DMEM), Hank's balanced salt solution(HBSS), milk, saline, and green tea in for 1, 2, 3 hours. And, MTT assay was conducted to compare survival rate of human gingival fibroblasts. Results : 1. The survival rate of gingival fibroblasts in DMEM and HBSS was higher than thoes in other storage media( Milk> Saline> Green tea). 2. The survival rate of gingival fibroblasts in milk, saline and green tea decreased as time passed. 3. Because of low osmotic pressure, green tea showed decrease of survival rate of gingival fibroblasts. Conclusion : DMEM and HBSS were the most effective storage media for gingival fibroblast. Among milk, saline, green tea, milk is most effective storage media for keeping gingival fibroblasts. Milk is recommended for storage media of avulsed tooth for keeping viability of cells.

Expression of receptors of Vitamin D and cytokines in osteoclasts differentiated by M-CSF and ODF (Macrophage Colony-Stimulating Factor와 Osteoclast Differentiation Factor로 분화 유도된 생쥐 파골세포에서 Vitamin D 및 수종의 싸이토카인 수용체의 발현)

  • Seong, Soo-Mi;Um, Heung-Sik;Ko, Sung-Hee;Woo, Kyung-Mi;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.865-873
    • /
    • 2002
  • The primary cause of tooth loss after 30 years of age is periodontal disease. Destruction of alveolar bone by periodontal disease is done by bone resorbing activity of osteoclasts. Understanding differentiation and activation mechanism of osteoclasts is essential for controling periodontal disease. The purpose of this study is to identify the possible effects of Vitamin D and cytokines affecting osteoclasts and its precursor cells. Four to six week-old mice were killed and humerus, radius, tibia and femur were removed aseptically and washed two times with Hank's solution containing penicillin-streptomycin and then soft tissue were removed. Bone marrow cells were collected by 22 gauge needle. Cells were cultured in Hank's solution containing 1 mg/ml type II collagenase, 0.05% trypsin, 41mM EDTA. Supernatant solution was removed 5 times after 15 minutes of digestion with above mentioned enzyme solution, and remained bone particles were maintained in alpha-MEM for 15 minutes and $4^{\circ}C$ temperature. Bone particles were agitated for 1 minute and supernatant solution containing osteoclast precursor cells were filtrated with cell stainer. These separated osteoclast precursor cells were dispensed with 100-mm culture dish by $1{\times}10^7$ cells unit and cultured in ${\alpha}$- MEM containing 20 ng/ml recombinant human M-CSF, 30 ng/ml recombinant human soluble osteoclast differentiation factor and 10% fetal calf serum for 2 and 7 days. Total RNA of osteoclast precursor cells were extracted using RNeasy kit. One ${\mu}g$ of total RNA was reverse transcribed in $42^{\circ}C$ for 30 minutes using SuperScriptII reverse transcriptase. Expression of transcribed receptors of each hormone and cytokine were traced with 1 ${\mu}l$ of cDNA solution by PCR amplification. Vitamin D receptor WAS found in cells cultured for 7 days. TNF-${\alpha}$ receptor was found in cells cultured for 2 days and amount of receptors were increased by 7 days. IL-1 type I receptor was not found in cells cultured 2 and 7 days. But, IL-1 receptor type II was found in cells cultured for 2 days. TGF-${\alpha},{\beta}$type I receptor was found in cells cultured 2 and 7 days, and amount of receptors were increased by 7 days of culture. These results implies Vitamin D and cytokines can affect osteoclasts directly, and affecting period in differentiation cycle of osteoclasts is different by Vitamin D and cytokines.

Effect of Nitrogen Ion Implantation on Wear Behavior of Biocompatible Ti Implant (질소이온 주입이 생체적합성 티타늄 임플란트의 마모특성에 미치는 영향)

  • Byeon, Eung-Seon;Kim, Dong-Su;Lee, Gu-Hyeon;Jeong, Yong-Su
    • 연구논문집
    • /
    • s.30
    • /
    • pp.137-145
    • /
    • 2000
  • Since the concept of osseointegration was introduced, titanium and titanium-based alloy materials have been increasingly used for bone-anchored metal in oralmaxillofacial and orthopedic reconstruction. Successful osseointegration has been attributed to biocompatibility and surface condition of metal implant among other factors. Although titanium and titanium alloys have an excellent over the metal ion release and biocompatibility, considerable controversy has developed over the metal ion and wear debris in vivo and vitro. In this study, nitrogen ion implantation technique was used to improve the corrosion resistance and wear property of titanium materials, ultimately to enhance the tissue reaction to titanium implants As ion implantation energy was increased, projected range of nitrogen ion the Ti substrate was gradually increased. Under condition of constant ion energy. atomic concentration of nitrogen was also increased with ion doses. The friction in Hank's solution was increased with ion doses. The friction coefficient of ion implanted specimens in HanK's solution was increased from 0.39, 0.47 to 0.52, 0.65 respectively under high energy and ion dose conditions. As increasing ion energies and ion dose, amount of wear was reduced.

  • PDF

Effect of diluent variation on cryopreservation of large yellow croaker Larimichthys crocea

  • Lim, Han Kyu;Irfan, Zidni;Lee, Hyo Bin;Song, Ji Hoon;Lee, Yun Ho
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.2
    • /
    • pp.63-77
    • /
    • 2021
  • The aim of this research was to investigate different factors, including cryoprotective agents (CPAs), diluents, dilution ratios, equilibrium times, freezing rates, and thawing methods to optimize cryopreservation protocols for large yellow croaker (Larimichthys crocea). The parameters evaluated were sperm motility, sperm activity index (SAI), survival rate, and DNA damage. Different types of CPAs, such as dimethyl sulfoxide (DMSO), propylene glycol (PG), ethylene glycol (EG), methanol, and glycerol, were tested for sperm preservation. The highest motility, SAI, and survival rate were observed when EG was used. Different diluents such as Stein's solution, Hank's balanced salt solution, marine fish Ringer's solution, artificial seminal plasma (ASP) of small yellow croaker, and Cortland solution were investigated. The highest post-thaw motility was observed upon using ASP as the diluent. Different concentrations of EG were then mixed with ASP to identify the optimal EG concentration. Experimental results showed that the motility (70.33 ± 1.20%), SAI (5), and survival rate (78.30 ± 0.42%) of post-thaw sperm were optimum when 10% EG and ASP were used as the CPA and diluent of cryopreservation, respectively. Post-thaw sperm motility was high at equilibration times below 150 s and at an optimum dilution ratio of 1:1 (sperm: CPA + diluent) and was not significantly different compared with fresh sperm motility. The freezing rate was found to be slow below -10℃/min. The thawing temperature of 45℃ was identified as ideal. The percentage of tail DNA in post-thaw sperm at 10% EG and ASP was also investigated and was found to have more significant DNA damage than that in fresh sperm but significantly lower damage than that in post-thaw sperm at EG concentrations of 5%, 15%, and 20% (p < 0.05). The cryopreservation protocols obtained in this study will be useful in large yellow croaker hatcheries.

Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel (초내식성 스테인레스강의 금속이온용출특성 및 세포적합성)

  • Kim, Cheol-Sang;Park, Jin-Soo;Her, Erk;Khang, Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF