• Title/Summary/Keyword: HF cleaning

Search Result 50, Processing Time 0.027 seconds

A Study on the Removal of Cu and Fe Impurities on Si Substrate (Si 기판에서 구리와 철 금속불순물의 제거에 대한 연구)

  • Choi, Baik-Il;Jeon, Hyeong-Tag
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.837-842
    • /
    • 1998
  • As the size of the integrated circuit is scaled down the importance of Si cleaning has been emphasized. One of the major concerns is abut the removal of metallic impurities such as Cu and Fe on Si surface. In this study, we intentionally contaminated Cu and Fe on the Si wafers and cleaned the wafer by cleaning splits of the chemical mixture of $\textrm{H}_2\textrm{O}_2$ and HF and the combination of HF treatment with UV/$\textrm{O}_3$ treatment. The contamination level was monitored by TXRF. Surface microroughness of the Si wafers was measured by AFM. The Si wafer surface was examined by SEM. AES analysis was carried out to analyze the chemical composition of Cu impurities. The amount of Cu impurities after intentional contamination was abut the level of $\textrm{10}^{14}$ atoms/$\textrm{cm}^2$. The amount of Cu was decreased down to the level of $\textrm{10}^{10}$ atoms/$\textrm{cm}^2$ by cleaning splits. The repeated treatment exhibited better Cu removal efficiency. The surface roughness caused by contamination and removal of Cu was improved by repeated treatment of the cleaning splits. Cu were adsorbed on Si surface not in a thin film type but in a particle type and its diameter was abut 100-400${\AA}$ and its height was 30-100${\AA}$. Cu was contaminated on Si surface by chemical adsorption. In the case of Fe the contamination level was $\textrm{10}^{13}$ atoms/$\textrm{cm}^2$ and showed similar results of above Cu cleaning. Fe was contaminated on Si surface by physical adsorption and as a particle type.

  • PDF

The study on the Removal of Metallic Impurities with using UV/ozone and HF cleaning (금속불순물 제거를 위한 UV/ozone과 HF 세정연구)

  • Lee, Won-Jun;Jeon, Hyeong-Tak
    • Korean Journal of Materials Research
    • /
    • v.6 no.11
    • /
    • pp.1127-1135
    • /
    • 1996
  • 반도체 소자가 고집적화 됨에 따라 단위공정의 수가 증가하게 되었고 동시에 실리콘 기판의 오염에 대한 문제가 증가하였다. 실리콘 기판의 주 오염물로는 유기물, 파티클, 금속분순물 등이 있으며 특히, Cu와 Fe과 같은 금속불순물은 이온주입 공정, reactive ion etching, photoresist ashing과 같은 실 공정 중에 1011-1013atoms/㎤정도로 오염이 되고 있다. 그러나 금속불순물 중 Cu와 같은 전기음성도가 실리콘 보다 큰 오염물질은 일반적인 습석세정방법으로는 제거하기 힘들다. 따라서 본 연구에서는 Cu와 Fe과 같은 금속불순물을 제거할 목적을 건식과 습식 세정방법을 혼합한 UV/ozone과 HF세정을 제안하여 실시하였다. CuCI2와 FeCI2 표준용액으로 실리콘 기판을 인위적 오염한 후 split 1(HF-only), split 2 (UV/ozone+HF), split 3 (UV/ozone + HF 2번 반복), split 4(UV/ozone-HF 3번 반복)를 실시하였고 TXRF(Total Reflection X-Ray Fluorescence)와 AFM(Atomic Force Microscope)으로 금속불순물 제거량과 표면거칠기를 각각 측정하였다. 또한 contact angle 측정으로 세정에 따른 표면상태도 측정하였다. TXRF 측정결과 split 4가 가장 적은 양의 금속불순물 잔류량을 보였으며 AFM 분석을 통한 표면거칠기도 가장 작은 RMS 값을 나타내었다. Contact angle 측정 결과 UV/ozone 처리는 친수성 표면을 형성하였고 HF처리는 소수성 표면을 형성하였다.

  • PDF

Study on the Direct Bonding of Silicon Wafers by Cleaning in $HNO_3:H_2_O2:HF$ (HNO$_3:H_2O_2$ : HF 세척법을 이용한 실리콘 직접 접합 기술에 관한 연구)

  • Joo, C.M.;Choi, W.B.;Kim, Y.S.;Kim, D.N.;Lee, J.S.;Sung, M.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3310-3312
    • /
    • 1999
  • We have studied the method of silicon direct bonding using the mixture of $HNO_$, $H_2O_2$, and HF chemicals called the controlled slight etch (CSE) solution for the effective wafer cleaning. CSE, two combinations of oxidizing and etching agents, have been used to clean the silicon surfaces prior to wafer bonding. Two wafers of silicon and silicon dioxide were contacted each other at room temperature and postannealed at $300{\sim}1100^{\circ}C$ in $N_2$ ambient for 2.5 h. We have cleaned silicon wafers with the various HF concentrations and characterized the parameters with regard to surface roughness, chemical nature, chemical oxide thickness, and bonding energy. It was observed that the chemical oxide thickness on silicon wafer decreased with increasing HF concentrations. The initial interfacial energy and final energy postannealed at $1100^{\circ}C$ for 2.5h measured by the crack propagation method was 122 $mJ/m^2$ and 2.96 $mJ/m^2$, respectively.

  • PDF

The Removal of Si3N4 Particles from the Wafer Surface Using Supercritical Carbon Dioxide Cleaning (웨이퍼 표면의 Si3N4 파티클 제거를 위한 초임계 이산화탄소 세정)

  • Kim, Yong Hun;Choi, Hae Won;Kang, Ki Moon;Karakin, Anton;Lim, Kwon Teak
    • Clean Technology
    • /
    • v.24 no.3
    • /
    • pp.157-165
    • /
    • 2018
  • In this study, the removal of $Si_3N_4$ particles from the surface of a silicon wafer was investigated by using supercritical carbon dioxide, the IPA co-solvent and cleaning additive chemicals. First, the solubility of several surfactants and binders in supercritical carbon dioxide solubility and particle dispersibility in the binders were evaluated in order to confirm their suitability for the supercritical cleaning process. Particle removal experiments were carried out with adjusting various process parameters and reaction conditions. The surfactants used in the experiment showed little particle removal effect, producing secondary contamination on the surface of wafers. On the other hand, 5 wt% (with respect to $scCO_2$) of the cleaning additive mixture of trimethyl phosphate, IPA, and trace HF resulted in 85% of particle removal efficiency after $scCO_2$ flowing for 4 minutes at $50^{\circ}C$, 2000 psi, and the flow rate of $15mL\;min^{-1}$.

HF 플라즈마의 방전 특성 분석

  • Mun, Jang-Sik;Kim, Seon-Ho;Wang, Seon-Jeong;Gwak, Jong-Gu;Kim, Seong-Gyu;An, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.323-323
    • /
    • 2010
  • 핵융합 플라즈마에서 연료 주입과 불순물 제거는 매우 중요한 과제로서 이를 해결하기 위한 방법으로 Glow Discharge Cleaning, ICRF Wall Conditioning과 같은 방법들을 이용한다. 최근 중국의 EAST 토카막 등에서 이러한 방법보다 보다 간소하고 효과적인 방법의 일환으로 수십에서 수백 kHZ의 HF 대역의 교류전원을 이용하여 플라즈마를 발생하고 이를 토카막 벽면의 Wall Conditioning에 적용하는 방법을 시도했다. 본 연구는 이러한 HF 플라즈마를 KSTAR 토카막 Wall Conditioning에 걱용하기 위한 예비 실험으로 선형 플라즈마 발생장치에 30kHZ 2kW급의 HF 파워를 이용하여 플라즈마를 발생하였다. 운전 압력에 따라 전압과 전류 특성을 파악하고 Langmuir probe를 이용하여 플라즈마 밀도와 온도들의 parameter를 측정하였다. 본 발표에서는 구체적인 플라즈마 발생장치를 소개하고 플라즈마 방전 특성과 parameter들을 보고할 예정이다.

  • PDF

Characterization of $HfO_2 /SiON$ stack structure for gate dielectrics (ALD를 이용한 극박막 $HfO_2 /SiON$ stack structure의 특성 평가)

  • Kim, Youngsoon;Lee, Taeho;Jaemin Oh;Jinho Ahn;Jaehak Jung
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.11a
    • /
    • pp.115-121
    • /
    • 2002
  • In this research we have investigated the characteristics of ultra thin $HfO_2 /SiON$stack structure films using several analytical techniques. SiON layer was thermally grown on standard SCI cleaned silicon wafer at $825^{\circ}C$ for 12sec under $N_2$O ambient. $HfO_2 /SiON$$_4$/$H_2O$ as precursors and $N_2$as a carrier/purge gas. Solid HfCl$_4$was volatilized in a canister kept at $200^{\circ}C$ and carried into the reaction chamber with pure $N_2$carrier gas. $H_2O$ canister was kept at $12^{\circ}C$ and carrier gas was not used. The films were grown on 8-inch (100) p-type Silicon wafer at the $300^{\circ}C$ temperature after standard SCI cleaning, Spectroscopic ellipsometer and TEM were used to investigate the initial growth mechanism, microstructure and thickness. The electrical properties of the film were measured and compared with the physical/chemical properties. The effects of heat treatment was discussed.

  • PDF

GaN Epitaxy with PA-MBE on HF Cleaned Cobalt-silicide Buffer Layer (HF 크리닝 처리한 코발트실리사이드 버퍼층 위에 PA-MBE로 성장시킨 GaN의 에피택시)

  • Ha, Jun-Seok;Chang, Ji-Ho;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.409-413
    • /
    • 2010
  • We fabricated 10 nm-thick cobalt silicide($CoSi_2$) as a buffer layer on a p-type Si(100) substrate to investigate the possibility of GaN epitaxial growth on $CoSi_2/Si(100)$ substrates. We deposited 500 nm-GaN on the cobalt silicide buffer layer at low temperature with a PA-MBE (plasma assisted-molecular beam epitaxy) after the $CoSi_2/Si$ substrates were cleaned by HF solution. An optical microscopy, AFM, TEM, and HR-XRD (high resolution X-ray diffractometer) were employed to determine the GaN epitaxy. For the GaN samples without HF cleaning, they showed no GaN epitaxial growth. For the GaN samples with HF cleaning, they showed $4\;{\mu}m$-thick GaN epitaxial growth due to surface etching of the silicide layers. Through XRD $\omega$-scan of GaN <0002> direction, we confirmed the cyrstallinity of GaN epitaxy is $2.7^{\circ}$ which is comparable with that of sapphire substrate. Our result implied that $CoSi_2/Si(100)$ substrate would be a good buffer and substrate for GaN epitaxial growth.

Charicteristics of HF 10-cm Type Grid Ion Source for Inert and Chemically Reactive Gases.

  • Chol, W.K;Koh, S.K;Jang, H.G;Jung, H.J;Kondranin, S.G.;Kralkina, E.A.;Bougrov, G.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1996.02a
    • /
    • pp.102-102
    • /
    • 1996
  • This paper represents a new type low power High Frequency technological ion source (HF TIS) for ion - beam processing: the surface modification of materials, cleaning of surface, sputtering, coating of thin films, and polishing. The operational principle of HF TIS is based on the excitation of electrostatic waves in plasma located in the external magnetic field. Low power HF TIS with diameter 92 rom gives the opportunity to obtain beams of inert and chemically reactive gases with currents range from 5 to 150 mA (current density $0.015\;~\;3.5\;mA/\textrm{m}^2$) and ion beam energy 100 ~ 2500 eV at a HF power level 10 ~ 150 W. Three grid concave type ion optical system (IOS) is used for extraction and formation ofion beam.n beam.

  • PDF

Etch Rate of Oxide Grown on Silicon Implanted with Different Ion Implantation Conditions prior to Oxidation

  • Joung, Yang-Hee;Kang, Seong-Jun
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.2
    • /
    • pp.67-69
    • /
    • 2003
  • The experimental studies for the etch properties of the oxide grown on silicon substrate, which is in diluted hydrogen fluoride (HF) solution, are presented. Using different ion implantation dosages, dopants and energies, silicon substrate was implanted. The wet etching in diluted HF solution is used as a mean of wafer cleaning at various steps of VLSI processing. It is shown that the wet etch rate of oxide grown on various implanted silicon substrates is a strong function of ion implantation dopants, dosages and energies. This phenomenon has never been reported before. This paper shows that the difference of wet etch rate of oxide by ion implantation conditions is attributed to the kinds and volumes of dopants which was diffused out into $SiO_2$ from implanted silicon during thermal oxidation.

Study on Aluminum Frame Surface Cleaning Process for Photomask Pellicle Fabrication (포토마스크 펠리클 제조를 위한 Aluminum Frame 표면 세정공정 연구)

  • Kim, Hyun-Tae;Kim, Hyang-Ran;Kim, Min-Su;Lee, Jun;Jang, Sung-Hae;Choi, In-Chan;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.25 no.9
    • /
    • pp.462-467
    • /
    • 2015
  • Pellicle is defined as a thin transparent film stretched over an aluminum (Al) frame that is glued on one side of a photomask. As semiconductor devices are pursuing higher levels of integration and higher resolution patterns, the cleaning of the Al flame surface is becoming a critical step because the contaminants on the Al flame can cause lithography exposure defects on the wafers. In order to remove these contaminants from the Al frame, a highly concentrated nitric acid ($HNO_3$) solution is used. However, it is difficult to fully remove them, which results in an increase in the Al surface roughness. In this paper, the pellicle frame cleaning is investigated using various cleaning solutions. When the mixture of sulfuric acid ($H_2SO_4$), hydrofluoric acid (HF), hydrogen peroxide ($H_2O_2$), and deionized water with ultrasonic is used, a high cleaning efficiency is achieved without $HNO_3$. Thus, this cleaning process is suitable for Al frame cleaning and it can also reduce the use of chemicals.