• Title/Summary/Keyword: H&S performance

Search Result 4,501, Processing Time 0.038 seconds

Performance assessment of advanced hollow RC bridge column sections

  • Kim, T.H.;Kim, H.Y.;Lee, S.H.;Lee, J.H.;Shin, H.M.
    • Computers and Concrete
    • /
    • v.16 no.5
    • /
    • pp.703-722
    • /
    • 2015
  • This study investigates the performance of advanced hollow reinforced concrete (RC) bridge column sections with triangular reinforcement details. Hollow column sections are based on economic considerations of cost savings associated with reduced material and design moments, as against increased construction complexity, and hence increased labor costs. The proposed innovative reinforcement details are economically feasible and rational, and facilitate shorter construction periods. We tested a model of advanced hollow column sections under quasi-static monotonic loading. The results showed that the proposed triangular reinforcement details were equal to the existing reinforcement details, in terms of the required performance. We used a computer program, Reinforced Concrete Analysis in Higher Evaluation System Technology (RCAHEST), for analysis of the RC structures; and adopted a modified lateral confining effect model for the advanced hollow bridge column sections. Our study documents the testing of hollow RC bridge column sections with innovative reinforcement details, and presents conclusions based on the experimental and analytical findings. Additional full-scale experimental research is needed to refine and confirm the design details, especially for the actual detailing employed in the field.

Performance analysis of the Resource Reservation Schemes using Mobile Cluster based H-MRSVP in Wireless Mobile Networks (무선 이동망에서 이동 클러스터 기반의 H-MRVP를 이용한 자원관리 기법의 성능 분석)

  • Ma, Gyeong-Min;Won, Jeong-Jae;Lee, Hyeong-U;Jo, Chung-Ho
    • The KIPS Transactions:PartC
    • /
    • v.9C no.2
    • /
    • pp.283-292
    • /
    • 2002
  • This paper develops a scheme of resource management for guaranteeing QoS of realtime traffic in wireless mobile internet environments Mobile terminal has significant impact on the QoS originating mobility provided to a real-time application. The currently proposed MRSVP is not clear the boundary of resource reservation tregion and also can give rise to signal overhead to maintain sessions. To solve above problem, we propose the new reservation protocol, mobile cluster based H-MRSVP to combine MRSVP with moving cluster concept. In this paper, we analytically design our model for guaranteeing the QoS of realtime traffic and compare the three schemes: guard channel allocation schemes, DCA and our model. The performance measures are the probabilities of new call blocking, handoff dropping, resource utilization and service completion versus the system offered Erlang load. Consequently, Simulation indicate our model is more flexible than DCA in a view pint of channel utilization and gains the advantage over guard channel scheme with respects to the mobility.

Performance Evaluation of Manhole Filter to Remove Odor Inside Sewage Pipe -Focused on Removal of Hydrogen sulfide- (하수관거 악취 제거를 위한 맨홀필터 악취제거장치 성능 평가 - 황화수소 제거를 중심으로 -)

  • Kim, Choong-Gon;Lee, Jang-Hown
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.4
    • /
    • pp.45-51
    • /
    • 2018
  • The objective of this study is to evaluate the applicability of a manhole-filter odor eliminator that is installed on a manhole to remove hydrogen sulfide ($H_2S$) contained in the sewage of urban streets; $H_2S$ is the very cause of offensive odor from such sewage. An analysis of the capability of impregnated activated carbon, which is contained in the manhole filter, to adsorb hydrogen sulfide shows that some 99.8% of hydrogen sulfide can be removed. A performance evaluation of the manhole-filter odor eliminator, which was made on Manhole Section 4 known as the representative malodorous manhole section of Seoul, Korea, indicates that more than 97% of hydrogen sulfide ($H_2S$), one of typical malodor-generating substances, can be eliminated. The results and findings of the study as described above suggest that the applicability of the manhole-filter odor eliminator to eliminate offensive odor generated from sewer manholes is satisfactory.

Parallel Performance of Preconditioned Navier-Stokes Code on Myrinet Environment (Myrinet 환경에서 예조건화 Navier-Stokes 코드의 병렬처리 성능)

  • Kim M.-H.;Lee G. S.;Choi J.-Y.;Kim K. S.;Kim S.-L.;Jeung I.-S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.149-154
    • /
    • 2001
  • Parallel performance of a Myrinet based PC-cluster was tested and compared with a conventional Fast-Ethernet system. A preconditioned Navier-Stokes code was parallelized with domain decomposition technique, and used for the parallel performance test. Speed-up ratio was examined as a major performance parameter depending on the number of processor and the network topology. As was expected, Myrinet system shows a superior parallel performance to the Fast-Ethernet system even with a single network adpater for a dual processor SMP machine. A test for the dependency on problem size also shows that network communication speed is a crucial factor for parallelized computational fluid dynamics analysis and the Myrinet system is a plausible candidate for high performance parallel computing system.

  • PDF

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Design of T-S Fuzzy Model Based H Controller for Diving Control of AUV: An LMI Approach (무인 잠수정의 깊이 제어를 위한 T-S 퍼지 모델 기반 H 제어기 설계: 선형 행렬 부등식 접근법)

  • Jun, Sung-Woo;Kim, Do-Wan;Lee, Ho-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.441-447
    • /
    • 2012
  • This paper presents a design technique of a Takagi-Sugeno (T-S) fuzzy-model-based $H_{\infty}$ controller for autonomous underwater vehicles (AUVs). The design procedure aims to render the stabilizing controller which satisfies performance of the diving control for AUVs in the presence of the disturbance. A nonlinear AUV is modeled by the T-S fuzzy system through the sector nonlinearity. By using Lyapunov function, the sufficient conditions are derived to guarantee the performance of robust depth control in the format of linear matrix inequality (LMI). To succeed for diving control of AUV, we add the constraints on the diving and pitch angles in the LMI conditions. Through the simulation, we confirm the effectiveness of the proposed methodology.

A study about an old age car performance characteristic (노후차량 성능 특성에 관한 연구)

  • Hong Yong-Ki;Kwon Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.332-337
    • /
    • 2005
  • In order to investigate performance changes, the acceleration, vibration, and braking performance tests were carried out on the electric multiple units (EMUs) with over 20 years operation. According to the testing results, in vibration and braking performance, the similar performance results were obtained as compared with newly manufactured EMUs. However, in terms of acceleration performance, below reference value (3.0 km/h/s) has been obtained. This is mainly due to performance deterioration including traction motor. The precision diagnosis evaluation of deteriorated EMUs will be provided through the overall evaluation of corrosion testing and structural performance of car body.

  • PDF

Heat Dissipation Trends in Semiconductors and Electronic Packaging (반도체 및 전자패키지의 방열기술 동향)

  • S.H. Moon;K.S. Choi;Y.S. Eom;H.G. Yun;J.H. Joo;G.M. Choi;J.H. Shin
    • Electronics and Telecommunications Trends
    • /
    • v.38 no.6
    • /
    • pp.41-51
    • /
    • 2023
  • Heat dissipation technology for semiconductors and electronic packaging has a substantial impact on performance and lifespan, but efficient heat dissipation is currently facing limited improvement. Owing to the high integration density in electronic packaging, heat dissipation components must become thinner and increase their performance. Therefore, heat dissipation materials are being devised considering conductive heat transfer, carbon-based directional thermal conductivity improvements, functional heat dissipation composite materials with added fillers, and liquid-metal thermal interface materials. Additionally, in heat dissipation structure design, 3D printing-based complex heat dissipation fins, packages that expand the heat dissipation area, chip embedded structures that minimize contact thermal resistance, differential scanning calorimetry structures, and through-silicon-via technologies and their replacement technologies are being actively developed. Regarding dry cooling using single-phase and phase-change heat transfer, technologies for improving the vapor chamber performance and structural diversification are being investigated along with the miniaturization of heat pipes and high-performance capillary wicks. Meanwhile, in wet cooling with high heat flux, technologies for designing and manufacturing miniaturized flow paths, heat dissipating materials within flow paths, increasing heat dissipation area, and reducing pressure drops are being developed. We also analyze the development of direct cooling and immersion cooling technologies, which are gradually expanding to achieve near-junction cooling.

A Management Performance Measurement Model of the Construction Engineering Firm -Focused on 'H' Construction Engineering Firm- (건설엔지니어링 기업의 경영성과측정모형 -H사의 사례를 중심으로-)

  • Park Chan-Sik;Kim Hyun-Jun;Jeon Yong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.2 s.18
    • /
    • pp.202-210
    • /
    • 2004
  • Under the current competitive business environment, the complexity of procurement method, and the lack of engineering capacity in the construction engineering industry, a construction engineering firms require the business strategy and its performance measurement system. This study suggests a performance measurement model that could follow 'H' construction engineering firm's vision and strategy. The model utilizes the concept of Balanced Scorecard. The study proposes the four main performance perspectives such as financial, growth, internal efficiency, and improvement & learning through the long-term strategy analysis, SWOT analysis, and interviews of the employees. Also the study develops the critical success factor and the key performance indicators. The usefulness of the performance measurement model is validated through the gap analysis such as alignment analysis and consensus analysis.