• Title/Summary/Keyword: Guided Light

Search Result 133, Processing Time 0.029 seconds

Independent Color Filtering of Differently Polarized Light Using Metal-Insulator-Metal Type Guided Mode Resonance Structure

  • Jung, Young Jin;Park, Namkyoo
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.180-187
    • /
    • 2016
  • The independent operation of a color filter for incident polarization is demonstrated using a guided-mode resonance (GMR) filter employing a metal-insulator-metal (MIM) waveguide. To achieve independent operation, a rectangular MIM grating is proposed as a wave-guide resonator. The design considerations are discussed and include how to determine the grating period and slit width. Power flow distribution is observed with slit width variation. Blue-green, green-red, and blue-red filters for corresponding x- and y-polarizations are demonstrated as application examples with numerical simulation with rectangle-shaped MIM grating. As a practical application, feasibility as a chromatic polarizer is discussed.

Comparative study on tissue responses of 3 resorbable membranes in rats (흡수성 차폐막의 조직반응에 관한 비교연구)

  • Hong, Seung-Bum;Kwon, Young-Hyuk;Lee, Man-Sup;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.475-488
    • /
    • 2002
  • The purpose of this study is to evaluate histologically the resorption and tissue response of various resorbable collagen membranes used for guided tissue regeneration and guided bone regeneration, using a subcutaneous model on the dorsal surface of the rat. In this study, 10 Sprague-Dawley male rats (mean BW 150gm) were used and the commercially available materials included acellular dermal matrix allograft, porcine collagen membrane, freeze-dried bovine dura mater. Animals were sacrificed at 2,6 and 8 weeks after implantation of various resorbable collagen membranes. Specimens were prepared with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows: 1. Resorption : Inner portion of porcine collagen membrane was resorbed a lot at 6 weeks, but its function was being kept for infiltration of another tissues were not observed. Freeze-dried bovine dura mater and acellular dermal allograft were rarely resorbed and kept their structure of outer portion for 8 weeks. 2. Inflammatory reactions : Inflammatory reaction was so mild and foreign body reaction didn't happen in all of resorbable collagen membranes, which showed their biocompatibility. 3. In all of resorbable collagen membranes, multinuclcated giant cells by foreign body reactions were not observed. Barrier membranes have to maintain their function for 4-6 weeks in guided tissue regeneration and at least 8 weeks in guided bone regeneration. According to present study, we can find all of the resorbable collagen membranes kept their function and structure for 8 weeks and were rarely resorbed. Foreign body reaction didn't happen and inflammatory reaction was so mild histologically. Therefore, all of collagen membranes used in this experiment were considered proper resorbable membranes for guided tissue regeneration and guided bone regeneration.

A wireless guided wave excitation technique based on laser and optoelectronics

  • Park, Hyun-Jun;Sohn, Hoon;Yun, Chung-Bang;Chung, Joseph;Kwon, Il-Bum
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.749-765
    • /
    • 2010
  • There are on-going efforts to utilize guided waves for structural damage detection. Active sensing devices such as lead zirconate titanate (PZT) have been widely used for guided wave generation and sensing. In addition, there has been increasing interest in adopting wireless sensing to structural health monitoring (SHM) applications. One of major challenges in wireless SHM is to secure power necessary to operate the wireless sensors. However, because active sensing devices demand relatively high electric power compared to conventional passive sensors such as accelerometers and strain gauges, existing battery technologies may not be suitable for long-term operation of the active sensing devices. To tackle this problem, a new wireless power transmission paradigm has been developed in this study. The proposed technique wirelessly transmits power necessary for PZT-based guided wave generation using laser and optoelectronic devices. First, a desired waveform is generated and the intensity of the laser source is modulated accordingly using an electro-optic modulator (EOM). Next, the modulated laser is wirelessly transmitted to a photodiode connected to a PZT. Then, the photodiode converts the transmitted light into an electric signal and excites the PZT to generate guided waves on the structure where the PZT is attached to. Finally, the corresponding response from the sensing PZT is measured. The feasibility of the proposed method for wireless guided wave generation has been experimentally demonstrated.

The State of Light Railway Industry (경전철 산업 현황)

  • Choi, Yong-Hoon;Yoon, Se-Kyun;Kim, Kyung-Taek;Chung, Kyung-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.454-458
    • /
    • 2005
  • Light railway system has many characteristics of better accessibility, frequency service, low construction cost, reduced air pollution and medium capacity public transport etc. Light railway system as a urban transportation system has been glowing worldwide since the late 20th century. More than 300 cities around the world have light railway systems. Many medium-size cities in domestic site is planning the construction of light railway. This paper reviews the domestic and foreign light railway system.

  • PDF

A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave (유도초음파를 이용한 3/4″ 배관 결함 검출 연구)

  • Chung, Woo Geun;Kim, Jin-Hoi;Cheon, Keun Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

Proposal of the Track Layout Criterion for the Light Rail Transit (경량전철 선로선형기준에 대한 제안)

  • 오지택;한승용;윤태양;성택룡
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.111-118
    • /
    • 2000
  • This paper proposes the track layout criterion for the LRT(light rail transit). All criterions established concerning dimension and performance of LRT vehicles that are three types. Types of vehices are AGT(automated guided train) steel wheel. AGT rubber tire and LIM(linear induction motor). Using theoritical approach, adaptation and validity of criterions are verified. Proposed criterions may provide a standard scheme for design and construction of the infrastructure on LRT.

  • PDF

Purchasing Behavior of K-pop Idol Goods Consumers in Korea

  • Kim, Yu Jin;Lee, Jieun;Lee, MiYoung
    • Journal of Fashion Business
    • /
    • v.22 no.6
    • /
    • pp.1-13
    • /
    • 2018
  • Idol goods refer to products such as cups and towels, or mementos or souvenirs that are manufactured to gratify the desires of fandom and may include the facial images of a star. The objective of this research was to explore the purchase behaviors of K-pop idol goods. Two hundred and sixty female idol goods purchasers in their twenties participated in an online survey. Cheering tools were the most often purchased idol goods, followed by idol slogans and dolls. To investigate the difference in idol goods' attributes they considered when shopping, respondents were divided into three purchase groups based on their annual total expense for purchasing idol goods. There were significant differences among light, medium and heavy purchasers in terms of goods' price, practical features, and scarcity. The light shopper group was majorly guided by price and practical features as compared to the other two groups, and heavy shopper group was majorly guided by scarcity attribute than in the other two shopper groups. The more they identified their favorite idols, the more they worked hard, the higher their income, the higher the expenses of investing in idol products, the more likely they were to repurchase idol goods. In term of post-purchase behavior of idol goods, most idol goods purchase by fans were stored rather than used, and few indicated that they purchase two identical idol goods for use and storage.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

The Vision-based Autonomous Guided Vehicle Using a Virtual Photo-Sensor Array (VPSA) for a Port Automation (가상 포토센서 배열을 탑재한 항만 자동화 자을 주행 차량)

  • Kim, Soo-Yong;Park, Young-Su;Kim, Sang-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.164-171
    • /
    • 2010
  • We have studied the port-automation system which is requested by the steep increment of cost and complexity for processing the freight. This paper will introduce a new algorithm for navigating and controlling the autonomous Guided Vehicle (AGV). The camera has the optical distortion in nature and is sensitive to the external ray, the weather, and the shadow, but it is very cheap and flexible to make and construct the automation system for the port. So we tried to apply to the AGV for detecting and tracking the lane using the CCD camera. In order to make the error stable and exact, this paper proposes new concept and algorithm for obtaining the error is generated by the Virtual Photo-Sensor Array (VPSA). VPSAs are implemented by programming and very easy to use for the various autonomous systems. Because the load of the computation is light, the AGV utilizes the maximal performance of the CCD camera and enables the CPU to take multi-tasks. We experimented on the proposed algorithm using the mobile robot and confirmed the stable and exact performance for tracking the lane.