Design of the Ground Resistance Measuring System to the Earth-Noise

  • Jung Min-Jae;Joo Hyung-Jun;Lee Ki-Hong;Oh Sung-Up;Jung Jae-Ki;Seong Se-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.566-570
    • /
    • 2001
  • Generally, grounding systems are responsible for the safe operation of a power system. Their performance guarantees equipment protection and personnel safety under condition of the limited ground potential rise and touch voltages as well as step voltages under ground fault conditions. Therefore, it is necessary to measure the ground resistance frequently for checking the performance of grounding system, In this paper the ground resistance measuring system using digital signal processor and high-performance L-C resonant band pass filter is presented. The signal current magnitude for measuring ground resistance in this system is $10^{-1}[A]\;to\;5\times10^{-2}[A]$ and the current frequency is 30[Hz].

  • PDF

대체 보조전극을 이용한 접지저항 측정값 비교 (Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

접지극의 공용화를 통한 접지저항 저감효과 분석 (Analysis of Ground Resistance Reduction Effect by Common use of Ground Poles)

  • 흥성택;이은춘;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.440-442
    • /
    • 2004
  • The ground resistance of middle scale ground pole was measured by using the 'fall of potential method' suggested by IEEE However, the measured resistance value was lower than the minimum value required To solve this problem. ground pole was set to be used commonly. In this research. ground resistance was measured using the newly suggested method and the results were analyzed to see if they satisfied the domestic regulation The results of this research will be applied to the management works as well as the establishment of new plan.

  • PDF

전위강하법에 의한 접지저항 측정시 보조전극의 위치변화에 따른 오차 분석 (Measurement Error Analysis of Ground Resistance Using the Fall-of-Potential Method According to the Locations of Auxiliary Probes)

  • 김동우;길형준;김동욱;이기연;문현욱;김향곤
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.222-231
    • /
    • 2010
  • This paper presents numerical analysis of measurement errors of ground electrode using the fall-of-potential method. In order to analyze ground resistance error according to the positions of auxiliary probes, firstly, national and international standards were researched. Secondly, numerical ground resistance error of hemispheric electrode was analyzed according to the locations of auxiliary probes and the angle between probes. Then, error-reduced positions of auxiliary probes were shown according to the distance to auxiliary current probe versus ground electrode size. Finally, error compensation method was presented. The results presented in this paper provide useful information regarding ground resistance error of alternative positions of auxiliary probes in case that the auxiliary probes could not be located at the proper position in such cases as there are buildings, roadblock or underground metallic pipe at that position.

다중접지계통의 접지저항 및 누설전류 자동측정장치 개발 (Development of a new Ground Resistance Tester for Power Electric Poles)

  • 손수국;정영호;최상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.675-678
    • /
    • 2000
  • This paper has proposed a new digital ground resistance tester for electrical systems. It features automatic operation with an injected current source. Without climbing electric power poles a worker can measure safely and quickly a ground resistance and current along the ground line.

  • PDF

축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석 (Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model)

  • 김점식;김도영;박용범;권신원;길경석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

현장시험에 의한 접지전극의 년간 변화 특성 (Characteristics of Seasonal Variations of Ground Electrodes by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.500-501
    • /
    • 2006
  • Ground resistance is very important element in distribution line of multi-grounded system. Therefore, use several kind of ground electrode materials to get ground resistance. In this study, examine about characteristics of seasonal variations of ground resistance by several kind of ground electrode material that is used to ground electrode of distribution line, and compares and evaluated characteristics of each ground electrode material.

  • PDF

봉상 접지전극에시 전류유입위치에 따른 임펄스 접지임피던스의 특성 (Behaviors of Impulse Ground Impedances Associated with the Current Injection Point in a Ground Rod)

  • 이복희;정동철;이수봉
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.94-100
    • /
    • 2005
  • 본 논문은 전류유입위치에 따른 봉상접지전극의 과도 및 실효임펄스임피던스의 특성에 관한 것으로 뇌격전류를 인가하여 실규모 접지봉에 대한 시간영역에서의 성능을 평가하였다. 임펄스전류가 가해진 봉상접지전극의 과도 접지임피던스는 접지저항보다 높게 나타났으며, 접지전극의 길이가 길어짐에 따라 접지저항과 실효임펄스접지임피던스는 감소되었다. 또한 실효임펄스접지임피던스는 짧은 시간범위에서는 급격하게 증가하였다. 접지저항의 저감은 접지시스템의 임펄스임피던스 특성의 개선에 결정적인 역할을 한다. 임펄스전류를 접지봉의 하단에 인가하였을 때 접지봉 전위의 파두부에 고주파의 진동 파형이 포함되고 실효임펄스임피던스는 다른 경우보다 높게 나타났다.

비탈면에 적용된 다구근 앵커의 보강효과 연구 (A Study On The Reinforcing Effect Multibell Anchor Applied To The Cut Slope)

  • 차경섭;김선주;김태훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1286-1293
    • /
    • 2010
  • The ground anchor used in domestic area, which resists by adhesion between anchor body and the ground to the external force, seems not to be adequate for soft ground and urban area where the boundary between structures is close because the ground is disturbed and lost its strength during boring. In order to overcome such a shortcoming an expanded anchor system has been developed. The ground expansion is accomplished by means of Pulse Discharge Technology. In this technology, a high voltage of electricity is stored and discharged in milliseconds which induces high pressure acting on the ground. By making a couple of bulbs, a passive resistance as well as shaft resistance are mobilized, and therefore a higher pullout resistance comparing existing ground anchors is developed.In this study, a couple of full scale tests were conducted in order to figure out how much the resistance of an expanded anchor increases comparing to the straight. As a result, it was found that a remarkable increase in ultimate pullout capacity is observed for the soft ground and as the number of bulb increases. In addtion, as a result of applying to a cut slope reinforcement, it appeared that the length of fixed zone of anchor can be reduced effectively.

  • PDF

광물질 혼화재를 혼합한 해양 콘크리트의 해석적 성능 평가 (Analytical Estimation of the Performance of Marine Concrete with Mineral Admixture)

  • 이방연;권성준;강수태
    • 한국건설순환자원학회논문집
    • /
    • 제3권4호
    • /
    • pp.301-306
    • /
    • 2015
  • 이 연구에서는 해양 콘크리트의 균열저항성 및 내구성을 향상시킨 고성능 해양 콘크리트 개발 연구의 일환으로 광물질 혼화재를 혼입한 콘크리트의 강도, 수화발열 특성 및 염해저항성에 대한 해석적 평가를 실시하였다. 고로슬래그와 플라이애시를 광물질 혼화재로 검토하였으며, 고로슬래그 치환율은 70%까지 플라이애시 치환율은 40%까지 검토하였다. 해석검토 결과, 고로슬래그 및 플라이애시 치환은 모두 압축강도를 크게 저하시키는 결과를 보였으며, 수화발열 특성에서는 고로슬래그는 영향이 적은 반면, 플라이애시는 수화발열량 저감에 크게 효과가 있는 것으로 나타났다. 염소이온 침투 특성에서는 고로슬래그는 침투저항성을 증대시키는 반면, 플라이애시는 저하시키는 경향을 보였다. 해석적 평가를 통해 수화열과 염해내구성을 동시에 고려할 경우, 적절한 양의 고로슬래그와 플라이애시를 함께 사용한 3성분계 시멘트 배합 구성이 효과적일 것으로 판단된다.