• 제목/요약/키워드: Ground layer

검색결과 1,152건 처리시간 0.032초

피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구 (A Study on the Determination of Depth of Soft Ground by Cone Resistance)

  • 신윤섭;김민철;김연정;김영웅
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

지반 탁월주기와 지반 운동특성에 관한 연구 (A Study on Predominant Periods and Attenuation Characteristics of Ground Motion)

  • 김소구;차정식;정형식
    • 한국지반공학회지:지반
    • /
    • 제11권2호
    • /
    • pp.139-156
    • /
    • 1995
  • 지반진동특성의 지진공학적인 정밀측정의 일환으로 지반진동의 탁월주기와 지반진동의 거리에 따른 감쇠특성을 현장실험을 통하여 조사하였다. 이 조사는 세가지 부분의 실험을 통하여 결과를 얻었다. 첫째, 지반의 탁월주기는 고감도 디지탈 속도지진계-3축성분 속도계를 이용하는 Seismometer와 디지탈 Seismograph를 이용하여 지반과 건물에서 일정한 주기를 가진 연속적인 미소진동으로 부터 지반 및 건물진동의 탁월주기를 계측하였다. 지반에서의 탁월주기는 0.18~0.23 sec, 건물2층의 탁월주기는 0.26~0.31 sec였다. 둘째, 지반 구조조사는 디지탈 탄성파탐사기를 이용하여 굴절법을 이용한 탄성파탐사를 실시하였다. 실험장소인 한양대학교 안산캠퍼스의 지층구조는 상부층(표토층: surface layer)은 저속도층으로서 662m1s, 하부층(지반층: base ground)은 2210m/s의 P파 속도를 갖고, 주시곡선도로부터 표토층의 두께는 약 7m로 검측되었다. 이것은 7m두깨의 표토층(top soil)과 그 하부에 사질 점토성의 지반층(base ground)이 존재함을 암시한다. 셋째, Seisgun을 이용하여 인공적인 탄성파 에너지원을 만들어 지반의 진동 감쇠특성을 조사 하였다. 거리 감쇠상수(spatial attenuation conf$\ulcorner$icient) Y는 거리에 따른 진폭 을 계산하여 Z-성분(vertical)은 0.0137, X-성분(longitudinal)은 0.0025, Y-성분(transverse)은 0.0290이고 Spatial QP의 값은 각각 5.913~7.575, 32.371 ~41.452, 2.794~3.579의 값이 산출되었었다. 이 결과 다른 두성분에 비해서 종방향(z-성분, longitudinal)성분은 감쇠경향이 낮음을 알 수 있다. 그러므로 이 경우에 구조물 설계시 종방향(x-성분, longitudinal)성분에 대 한 내진설계가 고려 되어야 할 것이다.

  • PDF

지표면 재하시 토층구성에 따른 지중응력분포에 관한 연구 (A Study on the Stress Distribution in Soil According to the Composition of the Soil Layer in Case of Surface Loading)

  • 임종석;정상균;하혁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.510-516
    • /
    • 2005
  • This research aims to verify the stress distribution in soil according to the composition of the soil layer in case of surface loading. For this purpose, loading tests with measurement of stresses in the soil on four kinds of layered model ground in laboratory were performed. Those are (1)homogeneous sand, (2)gravel underlain by sand, (3)sand underlain by clay and (4)gravel underlain by clay. Test results are compared and analysed for the compositions of the soil layers. based on the results obtained, it is found that the larger the difference of the strengths of upper and lower layer is, the smaller the stress in the soil in case of surface loading is.

  • PDF

대형 뉴메틱케이슨 강성기초의 접지압분포 (Distribution of Ground Contact Pressure under Rigid Foundation of Large Pneumatic Caisson)

  • 홍원표;여규권
    • 대한토목학회논문집
    • /
    • 제28권2C호
    • /
    • pp.105-115
    • /
    • 2008
  • 다양한 지층에 설치된 대형 뉴메틱케이슨의 강성기초에 작용하는 접지압분포를 파악하기 위하여 영종대교하부기초로 채택된 뉴메틱케이슨 시공시 실시한 현장계측자료를 분석하였다. 뉴메틱케이슨의 침설시 케이슨의 하부 접지면에 케이슨의 침설에 저항하여 저항력이 작용할 것이다. 이 저항력을 뉴메틱케이슨 기초저면 모서리에 설치한 반압계로 측정할 수 있었다. 그리고 이 저항력측정기록을 이용하여 접지압을 산정하였다. 측정기록의 분석결과 기반암구간에서 뉴메틱케이슨기초에 작용하는 접지압분포는 아래로 볼록한 형상의 접지압분포를 보이는 반면에 해성퇴적층과 풍화암층에서의 접지압분포는 위로 볼록한 형상을 보인다. 그리고 이들 접지압분포는 대체적으로 모든 지층에서 대칭분포를 나타내고 있다. 대형 뉴메틱케이슨기초에 작용한 최대접지압에 의하여 제시된 접지압분포는 Kgler(1936)와 Fang(1991)이 강성기초를 대상으로 제시한 접지압분포특성과 잘 일치하는 것으로 나타났다.

열대 태평양 연승어업 대상 황다랑어와 눈다랑어 어장 분포의 해황 특성 (Oceanic Characteristics of Fishing Ground for Yellowfin and Bigeye Tunas Caught by Korean Tuna Longline Fishery in the Tropical Pacific)

  • 양원석;조규대;문대연;고정락
    • 한국수산과학회지
    • /
    • 제38권3호
    • /
    • pp.196-204
    • /
    • 2005
  • The horizontal and vertical distribution of yellowfin tuna, Thunnus albacares (Bonnaterre) and bigeye tuna, Tunnus obesus (Lowe) in relation to oceanic conditions such as thermal structure produced during El Nino/La Nina episodes were analyzed on the basis of data sets for the catches and efforts from the Korean tuna longline fishery and for the oceanographic observations from the NOAA during 1982-2002 in the tropical Pacific. The high density of fishing ground appeared in the western Pacific ($5^{\circ}N-5^{\circ}S,\;160^{\circ}E-180^{\circ}W$) for yellowfin tuna and in the eastern Pacific ($5^{\circ}N-15^{\circ}S,\;130^{\circ}W-100^{\circ}W$) for bigeye tuna. yellowfin and bigeye tunas were mainly distributed at the 110-250 m layer and 245-312 m layer, respectively, in the western Pacific. However, in the eastern Pacific, they were mostly caught at the 116-161 m and 205-276 m layer for yellowfin tuna and bigeye tuna, respectively. It can be suggested that bigeye tuna be distributed in the deepest layer among tunas and show a vertical size stratification. It was observed that during the El Nino events the main fishing ground of yellowfin tuna shifted from the western Pacific toward the eastern Pacific. In the eastern Pacific which showed a higher density of bigeye tuna, the vulnerability of bigeye tuna caught by deep longline increased during the El Nino events due to deepening of thermocline layer and a more intensively distribution of the fish schools in the lower layer of thermocline during the El Nino events.

낙동강 조간대 연약지반의 지역별 점성토층 두께 추정 모델 개발에 관한 연구 (A Study on the Development of Model for Estimating the Thickness of Clay Layer of Soft Ground in the Nakdong River Estuary)

  • 안성인;류동우
    • 터널과지하공간
    • /
    • 제32권6호
    • /
    • pp.586-597
    • /
    • 2022
  • 본 연구에서는 국내 주요 연약지반으로 알려진 낙동강 조간대 지역의 압밀침하 취약성 평가에 활용할 상부 점성토층의 위치별 두께 정보를 추정할 수 있는 모델을 개발하였다. 두께정보 추정을 위하여 기계학습 알고리즘인 RF (Random Forest), SVR (Support Vector Regression), GPR (Gaussian Process Regression)과 지구통계기법인 정규크리깅(Ordinary Kriging)을 이용한 4가지 공간추정 모델을 개발하고 상호 비교하였다. 모델 개발을 위하여 수집한 연구지역의 시추공 자료 4,712개 중 상부점성토층이 존재하는 2,948개의 시추공 자료를 사용하였으며, 개발된 모델들의 성능을 정량적으로 평가하기 위하여 피어슨(Pearson) 상관계수와 오차제곱평균(mean squared error)을 사용하였다. 또한, 정성적 평가를 위하여 연구지역 전역에 상부점성토층의 두께를 추정하여 점성토층의 지역별 분포 특성을 상호 비교하였다.

투수층 매설에 의한 해빈안정화에 관한 연구 (A Study on Beach Stabilization by Laying Drainage Layer)

  • 허동수;이우동;전호성
    • 대한토목학회논문집
    • /
    • 제30권3B호
    • /
    • pp.325-335
    • /
    • 2010
  • 본 연구에서는 투수층 매설에 따른 해빈안정화의 효과를 논의하기 위하여, 파 투과성구조물 해빈/해저지반의 상호간섭을 직접해석 할 수 있는 3D-수치모델(LES-WASS-3D; 허동수와 이우동, 2007)을 이용하였다. 이 모델은 투과성구조물 내부의 유체저항으로서 층류저항, 난류저항, 관성저항을 포함하고 있으며 격자 크기보다 작은 와류를 고려하기 위하여 LES기법을 도입하고 있다. 먼저, 기존의 수리모형 실험치와 본 연구의 계산치를 비교 검토하여 이용한 수치모델의 타당성 및 유효성을 검증한 후, 해빈 내부에 투수층을 설치하여 수치시뮬레이션을 실시하였다. 수치실험결과를 통하여 투수층 매설에 따른 평균지하수위의 하강, 이안류 강도의 저하 등, 배수의 메커니즘을 파악한 후, 투수층의 배치형태(평균입경, 두께, 매설깊이, 경사) 및 입사파조건(파고, 주기)에 따른 해빈 내부의 평균지하수위분포에 대하여 고찰하였다.

선행하중과 Wick Drain공법에 의한 연약해성광토의 개량 (Improvement of Soft Marine Clay by Preloading and Wick Drain Method)

  • 유태성;박광준
    • 한국지반공학회지:지반
    • /
    • 제3권1호
    • /
    • pp.7-24
    • /
    • 1987
  • 울산만 북서측 임해지역체 발달된 연약해성점토를 개양하기 위하려 선행대중과 Wick Drain공법의 병용공법이 적용되었다. 상기 공법의 적용에 따른 연약해성점토의 거동 및 강침특성을 요명하여, 안전하고 신속하게 시공을 실시하기 위하여 현장계측에 의한 공학적인 시공관리를 실시하였다. 본 고는 연약해성점토를 개량하기 위하여 적용한 선행하중과 Wick Drain공법의 설계, 시공 및 안전관리방법을 수록하고 있다.

  • PDF

이중층 패치와 부분 제거된 접지면을 이용한 광대역 평판형 역 F 안테나의 설계 (Design of Wideband Planar Inverted-F Antenna Using Two-Layer Patches and Modified Ground Structure)

  • 이광재;이용희;강연덕;이택경
    • 한국전자파학회논문지
    • /
    • 제18권9호
    • /
    • pp.1015-1022
    • /
    • 2007
  • 본 논문에서는 이중층의 패치와 제거된 접지면을 이용하여 광대역 평판형 역 F 안테나(PIFA)를 설계하였다. 제안된 안테나는 급전부를 공유하게 한 이중 층 패치의 슬릿을 통해 공진점을 조절하였고 접지면을 부분 제거하여 임피던스 정합을 개선하였다. 대역폭은 VSWR 2 이하 기준 1,492 MHz(BW: 67.7 %, 1,457${\sim}$2,949 MHz)와 VSWR 2.5 이 하 기준 1,170 MHz(BW: 21 %, 4,970${\sim}$6,140 MHz)를 얻었다. 이는 DCS 1800, DCS1900, UMTS (W-CDMA), WiBro, WLAN(IEEE 802.11b), Satellite DMB, WLAN (IEEE802.11a) 총 7개의 무선 통신 서비스를 만족한다. 방사 패턴은 전 방향에서 신호의 송수신이 가능하였고 대역 내에서 주파수별 서로 유사한 형태를 가졌다.

모형실험을 통한 토목섬유 적용에 따른 쇄석배수층 통수능 평가 (Evaluation of Discharge Capacity for Gravel mat due to Geosynthetic Using Calibration Chamber Test)

  • 김재홍;임은상
    • 한국지반신소재학회논문집
    • /
    • 제13권2호
    • /
    • pp.11-20
    • /
    • 2014
  • 대단위 부지조성을 위해 해안연약지반을 매립후 공기단축 및 안정된 부지를 조성하고자 대부분 연직배수재를 이용하여 지반 개량을 시행한다. 이 과정에서 연약지반내 설치한 연직배수재를 통하여 지반내 간극수가 지표면의 수평배수층으로 이동하여 외부로 배출된다. 과거에는 이 수평배수층 재료로 모래를 사용하였으나 근래에는 재료 품귀 및 단가 상승으로 쇄석으로 조성하는데 상부 성토층과 혼재를 방지하기 위하여 토목섬유(P.P. Mat)를 설치한다. 토목섬유의 설치시 재료비 및 시공비가 발생하여 토목섬유 적용 필요성에 대하여 실내에서 모형토조를 이용하여 단계별로 하중을 달리하고 유입량을 변화시켜 실험한 결과 토목섬유 적용에 따른 통수능에는 큰 차이가 없음을 알 수 있었다.