Abstract
The records of field instrumentation, which have been performed on the pneumatic caisson used for substructure of the Youngjong Grand Bridge, were analyzed to investigate the ground contact pressure under rigid foundation of large pneumatic caisson embedded in various ground layers. During sinking the pneumatic caisson, the resisting force was mobilized against sinking the caisson at the contact area between bottom of the caisson and the ground. The resisting force could be measured by the reaction force gauges instrumented under the edge of bottom of the pneumatic caisson. And the ground contact pressure could be estimated by use of the measuring records of the resisting force. The ground contact pressure under rigid foundation of large pneumatic caisson shows concave distribution on bedrock, while convex distribution was shown in marine deposit soil layer as well as weathered rock layer. And, the ground contact pressure in various ground layers was distributed axis-symmetrically. The distribution shape of the ground contact pressure determined by the maximum pressure acting on foundation of the large pneumatic caisson showed good coincidence with the distribution shape proposed for rigid foundation by Kgler(1936) and Fang(1991).
다양한 지층에 설치된 대형 뉴메틱케이슨의 강성기초에 작용하는 접지압분포를 파악하기 위하여 영종대교하부기초로 채택된 뉴메틱케이슨 시공시 실시한 현장계측자료를 분석하였다. 뉴메틱케이슨의 침설시 케이슨의 하부 접지면에 케이슨의 침설에 저항하여 저항력이 작용할 것이다. 이 저항력을 뉴메틱케이슨 기초저면 모서리에 설치한 반압계로 측정할 수 있었다. 그리고 이 저항력측정기록을 이용하여 접지압을 산정하였다. 측정기록의 분석결과 기반암구간에서 뉴메틱케이슨기초에 작용하는 접지압분포는 아래로 볼록한 형상의 접지압분포를 보이는 반면에 해성퇴적층과 풍화암층에서의 접지압분포는 위로 볼록한 형상을 보인다. 그리고 이들 접지압분포는 대체적으로 모든 지층에서 대칭분포를 나타내고 있다. 대형 뉴메틱케이슨기초에 작용한 최대접지압에 의하여 제시된 접지압분포는 Kgler(1936)와 Fang(1991)이 강성기초를 대상으로 제시한 접지압분포특성과 잘 일치하는 것으로 나타났다.