• Title/Summary/Keyword: Ground Resistance

Search Result 1,049, Processing Time 0.023 seconds

Sulfate Attack Resistance of Cement Mortar containing Ground Calcium Carbonate (중질탄산칼슘을 혼입한 시멘트 모르타르의 황산염침식 저항성 평가)

  • Jung, Ho-Seop;Kim, Jong-Pil;Lee, Seung-Tae;Kim, Seong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.217-220
    • /
    • 2006
  • This paper describes a study undertaken to determine the effect of ground calcium carbonate(GCC) cement mortar with respect to sulfate attack. It were investigated visual appearance and expansion of cement mortars with GCC immersed in artificial solution of 5% sodium sulfate during 510days. According to increasing replacement of GCC, the expansion ratio was comparatively superior to GCC0 mortar specimen. The test results indicated that cement mortars with GCC was benefit the resistance of sulfate attack due to micro filler effect.

  • PDF

Evaluation of durability of an ECC(Engineered Cementitious Composite) designed with ground granulated blast furnace slag (고로슬래그 미분말이 혼입된 ECC(Engineered Cementitious Composite)의 내구성 평가)

  • Kim, Jeong-Su;Kim, Yun-Yong;Kim, Jin-Keun;Ha, Gee-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.329-332
    • /
    • 2006
  • This paper presents the experimental results for durability of an ECC designed with ground granulated blast furnace slag (BFS) through the test method of chloride ion resistance and freezing-thawing resistance. In order to compare with ECC, normal mortar was also tested. Test results showed that BFS ECC exhibited higher durability performance than ordinary mortar. These results suggest that by adding BFS in ECC, its matrix density is increased which results in decreased of deterioration and it also adds to the fiber bridging that contributes in control of cracking.

  • PDF

Simulation for current limiting characteristics of a resistive SFCL in the 22.9 kV distribution system (배전급 저항형 초전도 한류기의 전류제한특성에 대한 EMTDC 시뮬레이션)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Hwang, Si-Dole;Kim, Sang-Joon
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.268-271
    • /
    • 2000
  • We simulated the current limiting characteristics of a resistive SFCL with 16 ${\Omega}$ of resistance for a single line-to-ground fault in the 22.9 kV system. The transient current during the fault increased up to 6.33 kA, 5.80 kA and 3.71 kA without SFCL at the fault angles of 0${\circ}$,45${\circ}$ and 90${\circ}$, respectively. An resistive SFCL limited the fault current to 2.27 kA in a half cycle. The quench resistance of 16 ${\Omega}$ was suggested to be appropriate to limit the fault current in the 22.9 kV distribution system.

  • PDF

Characteristics of the SFCL by turn-ratio of three-phase transformer

  • Jeong, I.S.;Choi, H.S.;Jung, B.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.34-38
    • /
    • 2013
  • According to the increase of electric consumption nowadays, power system becomes complicated. Due to this, the size of single line-to-ground fault from power system also increases to have many problems. In order to resolve these problems effectively, an Superconducting Fault Current Limiter(SFCL) was proposed and continuous study has been done. In this paper, an SFCL was combined to the neutral line of a transformer. An superconductivity has the characteristics of zero resistance below critical temperature. because of this, SFCL has nearly zero resistance. so we connecting SFCL to neutral line will not only have any loss in the normal operation but also have the less burden of electric power because of only limiting the initial fault current. We analyzed the characteristics of current, voltage according to the changes of turn ratio of 3 phase system in case of combinations of an SFCL to the neutral line. It was confirmed that the limiting rate of initial fault current by the increase of turn ratio was reduced.

The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine (이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석)

  • Bae, Jongsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.

Thermal Influential factors of Energy pile considering Ground saturation (지반 포화조건을 고려한 에너지파일의 열적거동 인자분석)

  • Song, Jin-Young;Paek, Jin-Yeol;Yun, Tae-Sup;Jeong, Sang-Seom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.104-112
    • /
    • 2010
  • The thermal influential factor of energy pile system is investigated by considering the seasonal effect, saturation of ground, and fluid velocity based on the finite volume method. Analysis includes the evaluation of thermal resistance and corresponding heat exchange rate for each case. It is shown that the efficiency of heat exchange rate is more pronounced with higher fluid velocity due to the larger number of circulation for a given period. Through the parametric studies, it is also found that the degrees of saturation a little influenced thermal effect during 8 hours of operational scenario.

  • PDF

Estimation of compressibility for Busan clay by CPT (CPT를 이용한 부산점토의 압축특성에 관한 연구)

  • Hong, Sung-Jin;Lee, Moon-Joo;Shim, Seong-Hyeon;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.320-325
    • /
    • 2009
  • The constrained modulus, representative property to evaluate compressibility of soil, is needed to estimate the settlement of ground structure. A series of lab and field cone penetration tests for clayey soil of Busan new-port and Noksan industrial area were conducted to evaluate the estimation method of constrained modulus. Since CPT generates large deformation of ground, it is difficult to correlate the cone resistance with the constrained modulus. Therefore, appropriate correlation between them is essential to estimate the constrained modulus based on CPT results. The test results show that the ratio of the constrained modulus to the cone resistance is inversely proportional with plasticity index. Based on this result, the estimation method of constrained modulus for Busan clay is suggested.

  • PDF

Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground (연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구)

  • 원정윤;장병욱;우철웅;윤상묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.96-106
    • /
    • 2003
  • 134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

Comparative study of Dutchcone and piezocone test on soft ground (연약지반에 대한 기계식 및 전자식 콘관입시험 비교 연구)

  • 장병욱;김재현;김동범;윤상묵;원정윤
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.237-244
    • /
    • 2002
  • A comparative study of 134 mechanical (Dutch cone) and 9. electronic cone (Piezocone) penetration data from the southern part of Korea has been performed. In general, Dutch cone results may be different from piezocone results due to the difference in structure of the cones. Cone penetrometer test data were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986,1990) Cone factors of Dutch cone and piezocone test have empirically been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

  • PDF

Grounding Characteristics Analysis of the Rod-Type Grounding Electrodes used for Electric Distribution Systems (배전계통에 사용되는 봉형 접지전극의 접지 특성 분석)

  • Kim, Kyung-Chul;Jung, Ji-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.49-56
    • /
    • 2011
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the copper and concrete rod grounding electrodes. An equivalent transfer function model of the ground impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing the conventional grounding impedance.