• Title/Summary/Keyword: Ground Level

Search Result 2,531, Processing Time 0.026 seconds

Foundational Research on the Market Strategies and Current Status of Children's Indoor Theme Parks with Korean Characters as Their Theme (국산 캐릭터를 테마로 한 어린이 실내 테마파크의 현황 및 시장전략에 관한 기초연구)

  • Park, Seong-Sik
    • Cartoon and Animation Studies
    • /
    • s.28
    • /
    • pp.235-263
    • /
    • 2012
  • Regarding the theme park business as an area of cultural content business, this study focuses on the trend of pursuing indoor theme parks as a small-scale small capital strategy escaped from the existing approach oriented to large-scale outdoor complex theme parks. It is because although existing large-scale outdoor complex theme parks require the capital with the scale of hundreds of billion won and also high-level technique and the latest operational know-how that they have a great barrier for new entry as well as enormous risk, the rent indoor theme parks succeed in market entry with efficient risk management and flexible market strategies. Thereupon, this study examines the current status of the children's indoor theme park market with Korean characters as their theme as a new market among the indoor theme parks and also investigates the market strategies of this market in the two aspects of expansion: the expansion of Korean characters' property value and the expansion of the local theme park market. For that, this article reviewed the advanced researches on theme parks and divided the types of theme parks existing in Korea with the criteria of classification by space and theme or classification by main users. Also, among the children's indoor theme parks with Korean characters as their theme, this study visited five ones located in the capital area to examine the current status. And about two located in the capital area and also four in the local area, the current data were received from the persons in charge of the companies for analysis. Also, with the subjects of spectators visiting the 'DIBO VILLAGE, Cheonggye-cheon' newly opened on April 25th, 2012, the research on satisfaction was conducted for analysis. Through that, this study analyzed the structure of the existing children's indoor theme park business with Korean characters as their theme and suggested the ground to analyze the effectiveness of market strategies being implemented. It is expected that this study will establish the clues of systematic and profound discussion for the indoor theme park business that can be said to be the niche market of the theme park business and allow the small-scale areal indoor theme parks to be examined as a significant business model for the local theme park industry. In the aspect of character business as well, it is expected that this will give a chance to establish a new model of spatial storytelling expansion in terms of the property value of Korean animation characters.

THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS (법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향)

  • Koo, Bong-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.452-459
    • /
    • 2006
  • Competition will usually develop between the opposing walls as the restorative resin shrinks during polymerization. Magnitude of this phenomenon may be depended upon cavity configuration and volume. The purpose of this sturdy was to evaluate the effect of cavity configuration and volume on microleakage of composite resin restoration that has margins on the enamel site only. The labial enamel of forty bovine teeth was ground using a model trimmer to expose a flat enamel surface. Four groups with cylindrical cavities were defined, according to volume and configuration factor(Depth x Diameter / C-factor) - Group I : 1.5 mm ${\times}$ 2.0 mm / 4.0, Group II : 1.5 mm ${\times}$ 6.0 mm / 2.0, Group III : 2.Omm ${\times}$ 1.72 mm / 5.62, Group IV : 2.0 mm ${\times}$ 5.23 mm / 2.54. After treating with fifth-generation one-bottle adhesive - BC Plus$^{TM}$ (Vericom, AnYang, Korea), cavities were bulk flted with microhybrid composite resin - Denfill$^{TM}$ (Vericom). Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Specimens were thermocycled 500 times between 5$^{\circ}$C and 55$^{\circ}$C for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}$A) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. The results were as follows: 1. Small cavity volume showed lower microleakage score than large one, however, there was no statistically significant difference. 2. There was no relationship between cavity configuration and microleakage. Factors of cavity configuration and volume did not affect on microleakage of resin restorations with enamel margins only.

Distribution Patterns and Ecological Characters of Paulownia coreana and P. tomentosa in Busan Metropolitan City Using MaxEnt Model (MaxEnt 모형을 활용한 부산광역시 내 오동나무 및 참오동나무의 분포 경향과 생태적 특성)

  • Lee, Chang-Woo;Lee, Cheol-Ho;Choi, Byoung-Ki
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.2
    • /
    • pp.87-97
    • /
    • 2017
  • Paulownia species has long been recognized in Korean traditional culture and the values of the species have been researched in various focuses. However, studies on distribution and ecological characteristics of the species are still needed. This study aimed to identify distribution trends and ecological characteristics of two Paulownia species in Busan metropolitan city using the MaxEnt model. The MaxEnt model was established based on the environmental factors such as positioning information of the Paulownia species, topography, climate and degree of anthropogenic disturbance potentiality (ADP), which was collected in the on-site research. The study verified that the accuracy of the model was appropriate as the AUC value of Paulownia coreana and P. tomentosa was 0.809, respectively. In terms of the distribution trends of the two Paulownia species in the research area depending on the distribution model, they were both mainly distributed in downtown where built-up area and bare ground were densely concentrated. The potential distribution area of the two species was identified as $137.4km^2$ for P. coreana and $135.0km^2$ for P. tomentosa. The distribution probability was high in Jung-gu, Dongrae-gu, Busanjin-gu and Yeonje-gu. As a result of the analysis on contribution of the environmental factors, it was turned out that the degree of anthropogenic disturbance potentiality (ADP) contributed to distribution of P. coreana and P. tomentosa by about 50%, and the contribution of the environmental factors had a positive correlation with the degree of ADP. The elevation had a negative correlation with both the two species, which was considered because the species must compete more with native species in natural habitats as the altitude above sea level rises. The research findings demonstrated numerically that the distribution of P.coreana and P. tomentosa depended on artificial activities, and indicated the relevance with the Korean traditional landscape. These findings are expected to provide meaningful information in using, preserving and restoring Paulownia species.

Seed Germination, Seedling Grwoth and Optimal Seedling Density of Phellodendron amurense Rupr. in Nursery (황벽나무의 종자발아(種子發芽)와 묘목생장(苗木生長) 및 적정생육밀도(適正生育密度)에 관(關)한 연구(硏究))

  • Goo, Gwan-Hyo;Lee, Kang-Young;Youn, Ki-Sik;Lee, Chong-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.4
    • /
    • pp.443-449
    • /
    • 1997
  • We examined the effect of pretreatments on seed germination, seedling growth, optimal seedling density of Phellodendron amurense. The seeds were carefully purified after collection in late Oct. from natural population at Mt. Chiri. For the evaluation of pretreatment effects, seeds were sowed in an experimental nursery after being stored in open ground($2{\sim}8^{\circ}C$) with soaking in 20% $H_2O_2$, 50-fold pon-pon solution, cold moist stratification in refrigerator($2{\sim}4^{\circ}C$) and dry storage in roam temperature($4{\sim}18^{\circ}C$), respectively, For the effect of growth density of seedlings, seedlings germinated in nursery were precisely controlled with 53, 104, 220, 380 seedlings per $m^2$. Among pretreatments for the promotion of germination rate, pon-pon treatment(68.8%) was highest, the others were higher than that in dry storage(2.3%), and these seed pretreatment methods were significantly different at 1% level. The height growth of seedlings showed the most vigor from Jun.12 to Jul. 8, and from Jul.20 to Aug. 2, and it reached to 72.8% of height growth. In case of 1-0 seedling, although seedling density per $m^2$ was increased, seedling growth was decreased. The optimal seedling density was 104 seedlings per $m^2$. The standard seedlings for plantation were above height 55cm, root collar diameter 8.1mm, and root length 21cm. These results demonstrated that seed of P. amurense requires stratification for the germination promotion.

  • PDF

Effect of Organic Fertilizer Ratios on the Growth of Spiraea × bumalda 'Gold Mound' in the Container Green Wall Systems with Rainwater Utilization (빗물활용 벽면녹화 용기 내 유기질비료 배합비에 따른 노랑조팝나무의 생육 반응)

  • Ju, Jin-Hee;Kim, Hya-Ran;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1417-1423
    • /
    • 2011
  • For evaluating the effect of various organic fertilizer ratios on the Spiraea${\times}$bumalda 'Gold Mound' growth, a container green wall system experiment was conducted in a greenhouse at Konkuk university. The experimental planting grounds were prepared with different organic fertilizer ratios ($A_1L_0$, $A_8L_1$, $A_4L_1$ $A_2L_1$ and $A_1L_1$) and with drought tolerance and an ornamental value Spiraea${\times}$bumalda 'Gold Mound' was planted. The change in soil moisture contents, plant height, number of branches, number of dead leafs, number of leaf, number of shoots, length of node, length of leaf, width of leaf, root-collar caliper, chlorophyll contents and survival rate were investigated from April to Jun 2010. 1. The result of soil moisture contents was analyzed with weight unit in the container green wall system during the dry summer season. The soil moisture contents were significantly enhanced in the container green wall system in increasing order as the amount of fertilizer level increased $A_1L_1$ > $A_2L_1$ > $A_4L_1$ > $A_8L_1$ > $A_1L_0$. 2. Compared to the control treatment (amended soil with 100% + organic fertilizer 0%) application, the highest plant growth was observed in the treatment of $A_2L_1$(amended soil with 67% + organic fertilizer 13%) application. However, the differences between the organic fertilizer ratio treatments of $A_1L_1$, $A_4L_1$, $A_8L_1$, and the $A_1L_0$ organic fertilizer application were mostly not significant. 3. The survival rate increased with the increasing application of organic fertilizer, but in the control treatment (amended soil with 100% + organic fertilizer 0%) application all the plants died. Experimental results from the presented study clearly demonstrated that the organic fertilizer improved the survival rate more than the Spiraea${\times}$bumalda 'Gold Mound' growth at different levels of organic fertilizers. This strain can be utilized as a plant growth application in living wall systems during the dry summer season. Therefore, Spiraea${\times}$bumalda 'Gold Mound' is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in planting ground.

Quantitative evaluation of collapse hazard levels of tunnel faces by interlinked consideration of face mapping, design and construction data: focused on adaptive weights (막장관찰 및 설계/시공자료가 연계 고려된 터널막장 붕괴 위험도의 정량적 산정: 가변형 가중치 중심으로)

  • Shin, Hyu-Soung;Lee, Seung-Soo;Kim, Kwang-Yeom;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.5
    • /
    • pp.505-522
    • /
    • 2013
  • Previously, a new concept of indexing methodology has been proposed for quantitative assessment of tunnel collapse hazard level at each tunnel face with respect to the given geological data, design condition and the corresponding construction activity (Shin et al, 2009a). In this paper, 'linear' model, in which weights of influence factors are invariable, and 'non-linear' model, in which weights of influence factors are variable, are taken into account with some examples. Then, the 'non-linear' model is validated by using 100 tunnel collapse cases. It appears that 'non-linear' model allows us to have adapted weight values of influence factors to characteristics of given tunnel site. In order to make a better understanding and help for an effective use of the system, a series of operating processes of the system are built up. Then, by following the processes, the system is applied to a real-life tunnel project in very weak and varying ground conditions. Through this approach, it would be quite apparent that the tunnel collapse hazard indices are determined by well interlinked consideration of face mapping data as well as design/construction data. The calculated indices seem to be in good agreement with available electric resistivity distribution and design/construction status. In addition, This approach could enhance effective usage of face mapping data and lead timely and well corresponding field reactions to situation of weak tunnel faces.

On the Observation of Sandstorms and Associated Episodes of Airborne Dustfalls in the East Asian Region in 2005 (2005년 동아시아 지역에서 발생한 모래폭풍과 먼지침전(황사)의 관측)

  • Kim, Hak-Sung;Chung, Yong-Seung
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.196-209
    • /
    • 2009
  • Occurrences of sandstorms in the deserts and loess of Mongolia and northern China and associated dustfall episodes in the Korean Peninsula were monitored during the period January through December, 2005. False colour images were made by directly receiving the NOAA Advanced Very High Resolution Radiometer (AVHRR) data, and the distribution and transport of sandstorms were analyzed. The ground concentrations for PM10, PM2.5 and visibility of the dustfall episodes (PM10 concentration over $190{\mu}g\;m^{-3}$) were analyzed at Cheongwon, located midway in South Korea, and in the leeward direction of the place of origin of the sandstorms. Variations in the concentrations of $O_3,\;NO_2$, CO and $SO_2$ were also compared with dust concentrations in the dustfall episodes. Fewer occurrences of strong sandstorms in the place of origin were observed in 2005, due largely to the accumulation of snow and mild fluctuations of high and low pressure systems in the place of origin, thereby accounting for a low frequency of dustfall episodes in Korea, compared with those during the period 1997-2005. A total of 7 dustfall episodes were monitored in Korea in 2005 that lasted 11 days. In summer, sandstorms occurred less frequently in the source region in 2005 due to high humidity and milder winds, thereby causing no dustfall episodes in Korea. In case the sandstorms occurring at the place of source head directly to Korea without passing through large cities and industrial areas of China, the PM2.5 concentrations were measured at 20% or lower than the PM10 concentrations. However, when the sandstorms headed to Korea via the industrial areas of eastern China, where they pick up anthropogenic air pollutants, the PM2.5 concentrations were at least 25% higher of the PM10 concentrations. On the other hand, over 5 cases were observed and analyzed in 2005 where the PM10 concentrations of sand dust originating from the deserts were measured at $190{\mu}g\;m^{-3}$ or lower, falling short of the level of a dustfall episode.

A Case study and Analysis on the Up-Lift Pressure Treatment Evaluation of Underground Installations for their Efficient Adoption (사례분석을 통한 효율적 상향수압(Up-Lift Pressure) 처리공법 적용방안에 관한연구 - ◯◯ 상업지역 현장사례 중심으로 -)

  • Ko, Ok-Yeol;Kwon, Oh-Chul;Shim, Jae-Kwang;Park, Tae-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.119-129
    • /
    • 2009
  • Building construction trends have been changed dramatically in terms of size and mass. With the need to maximize land usage, there has been an increase in the construction of high-rise buildings. This affects not only the entire construction duration and cost, but also subsequent construction activities, such as work to increase underground facilities and in reclamation land area construction. These types of site conditions require soft ground reinforcement and the proper uplift water pressure treatment. In general, two kinds of methods have been used for uplift water pressure treatment systems. However, there have been some problems arising as the result of a lack of research and analysis on underground construction techniques, and a reliance on experiments over actual survey and analysis of site conditions. This paper focused on the problems of conventional selection procedure, by analyzing drawings and proposing a kind of modeling for a reasonable procedure. The results were applied to OO project as a sample construction case to be verified in this research. The initial plan in the case project was the Rock Anchor System. However, as there were terrible miscalculations of basic site conditions that had an extraordinary influence on the underground water level, such as the site's proximity to the Han-river, it was necessary to change the plan to include apermanent drainage system. This achieved a direct construction cost reduction \ 406,702,000 and a maximum sayings of 4% of operational cost, based on the 50-year building Life Cycle Cost.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

The Scale-dependent of Hydraulic Conductivity in Leaky Confined Aquifer with High Permeability at the Ttaan Isle, Gimhae City (김해 딴섬의 고투수성 누수 피압대수층에서 수리전도도의 규모종속효과)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Kim, Sung-Soo;Kim, Byung-Woo;Kwon, Byung-Hyuk
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • Pumping test was conducted to understand hydraulic conductivity for leaky confined aquifer with high permeability. Test aquifer was formed in $25{\sim}35\;m$ below ground surface at predetermined site of riverbank filtration which junction of Nakdong river and Milyang river in the Ttaan isle, Gimhae city, Korea Monitoring wells were located at intervals of 2 m and 5 m from pumping well in south-west direction (MW1 and MW2 wells) and northeast direction (MW3 and MW4 wells), respectively. Pumping test was continuously conducted for constant pumping rate of $2,500m^3/day$, hydraulic conductivity was estimated using AQTESOLV 3.5 program. Hydraulic conductivity were estimated to be $1.745{\times}10^{-3}m/sec$ for pumping well (PW), $2.452{\times}10^{-3}m/sec$ for between PW and MW1 wells, $2.161{\times}10^{-3}m/sec$ for between PW and MW2 wells, $2.270{\times}10^{-3}m/sec$ for between PW and MW3 wells and $2.591{\times}10^{-3}m/sec$ for between PW and MW4 wells. The function of hydraulic conductivity (K) as monitoring distance (d) were estimated to be logK = 0.0693logd - 2.671 for south-west direction (PW-MW1-MW2 line), logK = 0.0817logd - 2.655 for north-east direction (PW-MW3-MW 4 line). Scale exponent of hydraulic conductivity as test volume was estimated using Schulze-Makuch et al.(1999) method. Scale exponent of this aquifer was estimated to be 0.15. It means that test aquifer has very low heterogeneity. The radius of influence estimated using transmissivity, maximum groundwater level displacement, distance from pumping well and pumping rate during pumping test were 7.148 m for south-west direction and 6.912 m for north-east direction. The increasing rate of hydraulic conductivity from pumping well to maximum radius of influence were estimated to be 1.40 times for south-west direction and 1.49 times for north-east direction. Thus, heterogeneity of test aquifer was a little higher in north-east direction.