• Title/Summary/Keyword: Grafting degree

Search Result 109, Processing Time 0.023 seconds

Synthesis of High Affinity Anion Exchanger Using Ultrafine Fibrous PPmb Nonwoven Fabric by Co60 Irradiation Method (방사선 조사에 의한 초극세 폴리프로필렌 섬유부직포를 이용한 고효율 음이온교환체의 합성)

  • Choi, Kuk-Jong;Lee, Choul-Ho;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.509-515
    • /
    • 2008
  • The aminated polypropylene melt blown ion exchange fibers were synthesized with acrylic acid monomer onto polypropylene melt blown fibers by radiation-induced polymerization and subsequent amination. Degree of grafting was increased with increasing the acrylic acid monomer concentration and total dose. The highest degree of grafting was obtained 140% at a monomer concentration of 20 v/v% acrylic acid and total dose of 4 kGy. Optimum condition of Mohr's salt was 5.0 $\times10^{-3}$ M. Degree of amination was increased with increasing degree of grafting. Water content was about 1.5 times higher than that of trunk polymer. The maximum ion-exchange capacity was 7.3 meq/g which was 2$\sim$3 times higher than a commercial ion exchange fiber. The average pore size was decreased and BET surface area was increased in order of PPmb, PPmb- g- AAc and APPmb- g- AAc. The average pore size and BET surface area of synthesised fibers were $366.1\;{\AA},\;3.71m^2/g,\;143.3\;{\AA},\;4.94m^2/g,\;40.97\;{\AA},\;8.98m^2/g$, respectively.

Influence of Quaternary Ammonium Anion Exchange Moieties onto Mechanical Properties of Radiation-grafting Anion Exchange Membranes (방사선그라프팅 음이온교환막의 기계적 물성에 대한 4차 암모늄 음이온교환기의 영향)

  • Ko, Beom-Seok;Sohn, Joon-Yong;Shin, Junhwa
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 2012
  • Various anion exchange membranes were prepared by radiation graft copolymerization of vinylbenzyl chloride onto fluorinated films and subsequent quaternization with various tertiary amines such as trimethylamine, N,N-dimethylbuthylamine, N,N-dimethylaniline, and N-methylpiperidine. The quaternizations of the anion exchange membranes were confirmed by measuring of the ion exchange capacities of the membranes. The mechanical properties and the water uptakes were also measured. The elongation at break was found to be largely dependent on the fluorinated film, the quateranry ammonium, and the degree of grafting. The results indicate that the poly (ethylene-alt-tetrafluoroethylene) with quaternized trimethylamine moiety exhibits higher flexible property compared to the other prepared anion exchange membranes.

AN EXPERIMENTAL STUDY OF EFFECTS OF THE FIBRIN ADHESIVE ON BONE FORMATION PROCESS AFTER FREEZE DRIED DEMINERALIZED ALLOGENEIC BONE GRAFTS (냉동 건조 탈회 동종골 이식시 조직 접착제가 골 치유 과정에 미치는 영향에 관한 실험적 연구)

  • Kim, Chi-Kyeong;Kim, Soo-Nam;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.4
    • /
    • pp.365-378
    • /
    • 1995
  • Allogeneic bone grafting has recently been used in oral and maxillofacial regions to restore the cosmetic and functional problem. There are several types of allogeneic bone grafts ; bone powder, bone chips, bone blocks. Empirically, it is thought to be better to combine the allogeneic bone chips to any type of tissue adhesive not to displace during packing and condensing. But, there are no reports about using tissue adhesive in allogeneic bone grafting. This experimental study is designed to investigate the effect of the fibrin adhesive on bone healing process after demineralized allogeneic bone grafting in 60 rats. In control groups (30 rats), routine demineralized allogeneic bone grafting were done in 7 ${\times}$ 7mm calvarial bone defects which were drilled intentioally. And we used the fibrin adhesive for holding the bone particle in experimental groups (30 rats). Each experimental specimen was sacrified at 1, 2, 4, 6, 8 weeks postoperatively The results were as follows : 1. The degree of inflammatory cell infiltrations were more prominent in experimental than in control groups till 2 weeks. 2. Early fibroblast proliferation and new capillary proliferation were uncorporated around graft sites in the experimental groups later than in control groups at early stages. 3. Osteoblastic activity in control group was more prominent at 2 weeks. 4. Osteoblastic activity in experimental groups was more prominent than in control group till 4 weeks. 5. New bone formation was more in control group than experimental group till 3 weeks, but similar appearance after that time. As above results, initial bone healing within 2 weeks were more processed in without adhesive group than with adhesive group. But above 4 weeks; similar bone healing were observed.

  • PDF

Evaluation of the Effect of Solvent on the Preparation of PVBC-g-ETFE Film by a Pre-irradiation Method (전조사법에 의한 PVBC-g-ETFE 필름 제조 시 용매의 영향 평가)

  • Lee, Sun-Young;Song, Ju-Myung;Sohn, Joon-Yong;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.610-614
    • /
    • 2011
  • In this study, the effect of solvent on the pre-irradiation grafting of VBC(vinylbenzyl chloride) onto a ETFE(polyethylene-co-tetrafluoroethylene) was evaluated. ETFE film was irradiated to generate radical species onto its backbone chain. Each irradiated film was immersed into VBC monomer mixtures diluted with various solvents such as toluene, heptane, and isopropanol etc. for grafting process and then the degree of grafting of each film was measured. FTIR analysis confirmed that the VBC-g-ETFE film was successful prepared. For the films prepared in the various solvents, the mechanical strength and the distribution pattern of the graft polymer over the cross-section of the films were measured and the effect of solvent was evaluated.

Preparation and Characterization of Grafted Maleic Anhydride onto Polypropylene by Reactive Extrusion (반응 압출을 통한 PP-g-MA 제조 및 특성평가)

  • Kang, Dong-Jin;Lee, Sung-Hyo;Pal, Kaushik;Park, Chan-Young;Zhang, Zhen Xiu;Bang, Dae-Suk;Kim, Jin-Kuk
    • Polymer(Korea)
    • /
    • v.33 no.4
    • /
    • pp.358-363
    • /
    • 2009
  • Maleic anhydride-grafted polypropylene has been widely used to improve the interfacial interaction between the components in PP/polar polymer blends and PP/filler composites and to maximize the physical properties and thermal properties. In this paper. the maleic anhydride (MAH)-grafted polypropylene (co-PP) was fabricated through reactive extrusion process with di-cumyl peroxide (DCP) as an initiator. The grafting degree of MAH depending on the contents of DCP and MAH was investigated by FT-IR spectra and chemical titration. The grafting degree increased with increasing MAH concentration and also showed maximum value at 0.06 wt% of DCP concentration. Melt flow index (MFI) of the grafted copolymer was increased with increasing the contents of MAH. The DSC and TGA analysis data indicate the melting temperature and thermal degradation of PP depending on the grafting degree of MAH.

Developing A Stochastical Dynamic Analysis Technique for Structures Using Direct Integration Methods (직접적분법과 확률론적 유한요소법을 이용한 구조물의 확률론적 동적 해석)

  • 이정재
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.1
    • /
    • pp.54-62
    • /
    • 1994
  • The expanding technique of the Stochastic Finite Element Method(SFEM) is proposed in this paper for adapting direct integration methods in stochastical dynamic analysis of structures. Grafting the direct integration methods and the SFEM together, one can deal with nonlinear structures and nonstationary process problems without any restriction. The stochastical central diffrence and stochastic Houbolt methods are introduced to show the expanding technique, and their adaptabilities are discussed. Results computed by the proposed method (the Stochastic Finite Element Method in Dynamics: SFEMD) for two degree-of-free- dom system are compared with those obtained by Monte Carlo Simulation.

  • PDF

Preoperative implant planning considering alveolar bone grafting needs and complication prediction using panoramic versus CBCT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • Purpose: This study was performed to determine the efficacy of observers' prediction for the need of bone grafting and presence of perioperative complications on the basis of cone-beam computed tomography (CBCT) and panoramic radiographic (PAN) planning as compared to the surgical outcome. Materials and Methods: One hundred and eight partially edentulous patients with a need for implant rehabilitation were referred for preoperative imaging. Imaging consisted of PAN and CBCT images. Four observers carried out implant planning using PAN image datasets, and at least one month later, using CBCT image datasets. Based on their own planning, the observers assessed the need for bone graft augmentation as well as complication prediction. The implant length and diameter, the need for bone graft augmentation, and the occurrence of anatomical complications during planning and implant placement were statistically compared. Results: In the 108 patients, 365 implants were installed. Receiver operating characteristic analyses of both PAN and CBCT preoperative planning showed that CBCT performed better than PAN-based planning with respect to the need for bone graft augmentation and perioperative complications. The sensitivity and the specificity of CBCT for implant complications were 96.5% and 90.5%, respectively, and for bone graft augmentation, they were 95.2% and 96.3%, respectively. Significant differences were found between PAN-based planning and the surgery of posterior implant lengths. Conclusion: Our findings indicated that CBCT-based preoperative implant planning enabled treatment planning with a higher degree of prediction and agreement as compared to the surgical standard. In PAN-based surgery, the prediction of implant length was poor.

Multi-functional Finish of Polypropylene Nonwoven by Photo-induced Graft Polymerization (II) - Grafting of Styrene and Its Ammonia Adsorption Behavior - (광그라프팅에 의한 폴리프로필렌 부직포의 복합기능화 가공(II) -스티렌의 그라프트 반응 및 암모니아 흡착거동 -)

  • 김상률;최창남
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.642-648
    • /
    • 2001
  • An attempt was made to synthesize an ammonia adsorbent by the photo-induced grafting of styrene (St) onto polypropylene (PP) nonwoven using benzoin ethyl ether (BEE) as a photosensitizer with urea and trimethylol propane triacrylate in methanol medium. As styrene concentration was increased, the graft yield was increased. It was also found that the graft yield increased with reaction time. The polypropylene grafted with styrene (PP-g-St) was sulfonated by chlorosulfonic acid in dichloroethane and complexed with several metal ion, such as $cO^{+2}$, $nI^{+2}$, $cU^{+2}$, $Zn^{+2}$. The amount of ammonia gas adsorbed by these sample was dependent on the degree of sulfonation, adsorption time, and ammonia gas pressure. The adsorption capacity of ammonia gas by the sulfonated PP-g-St(SPP-g-St) nonwoven with 4. 25 mmol $H^+$/g was 6.61 mmol/g. Metal ion complexed SPP-g-St nonwovens had higher adsorption capacity than SPP-g-St nonwoven and the $Co^{+2}$ complexed SPP-g-St showed 9.90 mmol $NH_3$/g, which was much higher than that of active carbon or silica gel.

  • PDF

Ammonium Adsorption Property of Acrylic Acid and Styren Grafting Polypropylene Non-Woven Fabric Synthesized by Photo-induced Polymerization (광조사 중합법에 의해 합성된 PP-g-AA와 PP-g-St 부직포의 암모니아성 질소 흡착특성 비교)

  • Park, Hyun-Ju;Na, Choon-Ki
    • Journal of Environmental Science International
    • /
    • v.17 no.11
    • /
    • pp.1255-1263
    • /
    • 2008
  • The efficiency of PP-g-AA and PP-g-St nonwoven fabric synthesized by photoinduced polymerization as an adsorbent for removal $NH_3-N$ from waste water was evaluated. The results evidently indicate that the adsorption capacities of $NH_3-N$ onto PP-g-AA nonwoven fabric were extremely superior to those onto sulfonated PP-g-St nonwoven fabric, PK and zeolite. PP-g-AA nonwoven fabric showed the maximum adsorption capacity of $NH_3-N$ at the degree of grafting of 80 wt.%. The adsorption behaviour of $NH_3-N$ onto PP-g-AA and sulfonated PP-g-St nonwoven fabric was controlled by an ion exchange reaction, and tended to be similar to both trends of Langmiur and Freundlish isotherm. Futhermore, PP-g-AA non-woven fabric could be regenerated more than 5 times by a simple washing with 0.1N HCl with no decrease of adsorption capacity and no degradation of physical properties. Also sulfonated PP-g-St nonwoven fabric could be regenerated by washing with 0.1N ${H_2}{O_4}$. However, their regeneration efficiency was significantly low because grafting layer acted as functional radical for adsorption was continuously desquamated in the adsorption or regeneration processes, which resulted in decrease of adsorption capacity and weight of adsorbent. All results obtained from this study indicate that the $NH_3-N$ removal capacity of PP-g-AA non-woven fabric was extremely superior to those of PP-g-St non-woven fabric, PK and zeolite.

Preparation of Poly(vinylbenzyl chloride)-grafted Fluoropolymer Films by Using Radiation Grafting Method (방사선 그래프팅에 의한 염화비닐벤질 고분자가 그래프트된 불소필름의 제조)

  • Fei, Geng;Sohn, Joon-Yong;Lee, Youn-Sik;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.34 no.5
    • /
    • pp.464-468
    • /
    • 2010
  • In this study, a vinylbenzyl chloride (VBC) monomer was successfully grafted onto the several fluoropolymer films including poly(tetrafluoroethylene-co-hexafluoropropylene) (FEP), poly(tetrafluoroethylene-co-perfluoropropylvinyl ether) (PFA), and poly(ethylene-co-tetrafluoroethylene) (ETFE) films by using a simultaneous irradiation method. The results indicated that PVBC graft polymer can be easily grafted onto the ETFE film than other fluorinated films under the same irradiation condition. The grafted films were characterized by using FTIR, TGA, and SEM-EDS instruments. The elongation at the breaking of the grafted films was found to decrease with an increase of degree of grafting (DOG). The PVBC-grafted ETFE films were found to have better mechanical properties than other PVBC-grafted fluorinated films.