• Title/Summary/Keyword: Gil-ho Kim

Search Result 1,801, Processing Time 0.032 seconds

A Component Quality Assurance Process and its Application (컴포넌트 품질 관리 프로세스 개발 사례)

  • Kim, Gil-Jo;Jang, Jin-Ho;Hwang, Seon-Myeong
    • The KIPS Transactions:PartD
    • /
    • v.8D no.6
    • /
    • pp.699-704
    • /
    • 2001
  • Developing a component-based software requires verified and standardized software components. This paper presents a component quality management (CQM) process. The process was developed and applied to the government-sponsored trial projects that developed software components. The process is composed of four phases:quality specification, quality planning, quality control, and quality evaluation. With this process, we can establish quality goals and focus our efforts on the activities to achieve the goals. A component quality model is also suggested to transform the implicit quality requirements into the measurable quality goals and to be used for the basis when we evaluate the quality of software components against the quality goals.

  • PDF

An Analysis on the Preference Factors of Garden-Housing Consumers (전원주택단지 수요자의 입주선호요인 분석)

  • Kim, Jin-Sep;Lee, Chan-Ho;Choi, Gil-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5614-5621
    • /
    • 2011
  • The purpose of this thesis is to derive the demand expediting measures of the garden-housing site suitable to the Pusan metropolitan region through understanding the characteristics of the preference based on the investigation of the demand. From the empirical study of the thesis, we developed the following demand expediting strategies of the garden-housing site. First, the development concept should be focused on the market demand and community building. Second, the garden-housing site has to be developed near the existing urban areas and the site must have the convenient facilities and infrastructures. Third, community building concept should be applied in the site design.

Characteristics of Pre-Post Contacts of DC Consent-Plug (직류용 콘센트-플러그의 초기-후기접점 특성)

  • Na, Jae-Ho;Gil, Taekyun;Kim, Hyosung;Wang, Yongpeel
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.75-76
    • /
    • 2015
  • 콘센트-플러그는 사용자부하에 전기를 공급하기 위하여 필수적으로 사용하는 전기부품이다. 활선상태인 콘센트-플러그를 임의로 차단할 경우, 교류환경에서는 반주기 마다 전류의 영점이 존재하므로 차단접점에서 발생하는 아크가 자연적으로 소호될 수 있으나 직류환경에서는 개방직전 전류가 영점을 포함하지 않고 일정하기 때문에 그에 따라 발생하는 아크는 교류에 비해 지속적이고 상대적으로 매우 큰 에너지를 방출한다. 교류에서 사용되는 플러그와 콘센트를 그대로 직류에서 사용 할 경우, 접속이 끊어 질 때 매우 큰 아크전류가 발생하여 플러그와 콘센트의 전극이 녹아서 붙는 융착 사고가 빈번히 발생한다. 본 논문은 콘센트-플러그의 융착 사고를 예방하기 위해 전극의 초기-후기접점 기법을 제안한다. 이를 구현하기 위한 기초적인 연구로서 초기-후기접점 저항을 2단계로 구분하여 접속 및 차단 시 중간단계의 접촉저항을 통하여 부하전류가 단계적으로 바뀔 수 있도록 함으로써 최종 차단 아크전류를 감소시키는 방법을 제안하고 실험을 통하여 성능을 분석하고 설계방법을 제시한다.

  • PDF

Study on Etch Characteristics of BTO Thin Film by using $Cl_2$/Ar Inductively Coupled Plasma ($Cl_2$/Ar ICP 플라즈마를 이용한 BTO박막의 식각 특성 연구)

  • Kim, Man-Su;Min, Nam-Ki;Lee, Hyun-Woo;Choi, Bok-Gil;Kwon, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.177-178
    • /
    • 2007
  • 본 연구에서는 MIM (Metal-Insulator-Metal) capacitor의 유전 물질로 사용되는 $Ba_xTi_yO_z$(BTO) 박막의 식각 특성을 고찰하였다. $Cl_2$/Ar 혼합가스를 이용하여 Inductively Coupled Plasma(ICP)에서 BTO 박막을 식각하였고, 식각된 BTO박막의 표면을 X-ray photoelectron spectroscopy(XPS) 분석하였다. BTO박막의 식각 속도는 Ar이 80%인 식각 조건에서 31.7nm/min의 식각 속도를 추출하였고, 동시에 Pt박막에 대한 높은 선택비를 얻었다. X-ray photoelectron spectroscopy (XPS) 분석 결과로부터 표면 반응을 조사하여, 식각 기구를 고찰하였다.

  • PDF

Characterization of Nitrided $HfO_2(HfO_xN_y)$ for Gate Dielectric Application using Plasma (게이트 유전체 적용을 위한 플라즈마를 이용해 질화된 $HfO_2$ 박막의 특성 평가)

  • Kim,, Jeon-Ho;Choi, Kyu-Jeong;Yoon, Soon-Gil;Lee, Won-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.11-14
    • /
    • 2003
  • [ $HfO_2$ ] thin films were deposited at $300^{\circ}C$ on p-type Si (100) substrates using $HfO_2(HfO_xN_y)$ as the precursor by plasma-enhanced chemical vapor deposition and were annealed at $300^{\circ}C$ in nitrogen plasma ambient. Compared with $HfO_2$, nitrogen plasma annealed $HfO_2$ show good chemical stability, higher crystallization temperature, lower leakage current and thermal stability. Leakage current density of nitrogen plasma annealed $HfO_2$ is approximately one order of magnitude lower than that of $HfO_2$ for the same EOT. The improvement in electrical characteristics of nitrogen plasma annealed $HfO_2$ can be explained by the better thermal stability due to nitrogen incorporation.

  • PDF

Electrical Characterization of nano SOl wafer by Pseudo MOSFET (Pseudo-MOSFET을 이용한 nano SOI 웨이퍼의 전기적 특성분석)

  • Bae, Young-Ho;Kim, Byoung-Gil;Kwon, Kyung-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.3-4
    • /
    • 2005
  • The Pseudo-MOSFET measurements technique has been used for the electrical characterization of the nano SOL Silicon islands for the Pseudo-MOS measurements were fabricated by selective etching of surface silicon film with dry or wet etching to examine the effects of the etching process on the device properties. The characteristics of the Pseudo-MOS was not changed greatly in the case of thick SOI film which was 205 nm. However the characteristics of the device was dependent on etching process in the case of less than 100 nm thick SOI film. The sub 100nm SOI was obtained by thinning the silicon film of standard thick SOI. The thickness of SOI film was varied from 88 nm to 44 nm by chemical etching. The etching process effects on the properties of pseudo-MOSFET characteristics, such as mobility, turn-on voltage, and drain current transient. The etching process dependency is greater in the thinner SOI and related to original SOI wafer quality.

  • PDF

A Case of Erythema Nadosum Treated with Experimental Acupuncture (臨床的으로 診斷된 結節紅班의 實驗的 針 治療例)

  • Cho, Sung-Ho;Kim, Kyoung-Mee;Lee, Gil-Young
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.14 no.2
    • /
    • pp.271-277
    • /
    • 2001
  • Erythema nodosum is a nodular erythematous eruption predominently limited to the pretibial area but occasionally involving the arms or other areas. That is clinical entity defined easily but there are many different opinions about histopathologic findings, Recently erythema nodosum is characterized histopathologically by a septal panniculitis in which the fibrous septa of subcutaneous fat become inflamed. Erythema nodosum has been known to be frequently associated with some kinds of drugs, infections with streptococci, mycobacteria but in $60\%$, no cause is found, Treatment of erythema nodosum consists of supportive care and elimination of underlying causes. Because spontaneous resolution of the lesions can occur in 3 to 6 weeks. Although there are trial treatments are applied to erythema nodosum, ego corticosteroids, NSAIDs, potassium iodine, there isn't any definite. So We report a case of erythema nodosum which was not relieved by NSAIDS but by experimental acupuncture treatment.

  • PDF

A MFCC-based CELP Speech Coder for Server-based Speech Recognition in Network Environments (네트워크 환경에서 서버용 음성 인식을 위한 MFCC 기반 음성 부호화기 설계)

  • Lee, Gil-Ho;Yoon, Jae-Sam;Oh, Yoo-Rhee;Kim, Hong-Kook
    • MALSORI
    • /
    • no.54
    • /
    • pp.27-43
    • /
    • 2005
  • Existing standard speech coders can provide speech communication of high quality while they degrade the performance of speech recognition systems that use the reconstructed speech by the coders. The main cause of the degradation is that the spectral envelope parameters in speech coding are optimized to speech quality rather than to the performance of speech recognition. For example, mel-frequency cepstral coefficient (MFCC) is generally known to provide better speech recognition performance than linear prediction coefficient (LPC) that is a typical parameter set in speech coding. In this paper, we propose a speech coder using MFCC instead of LPC to improve the performance of a server-based speech recognition system in network environments. However, the main drawback of using MFCC is to develop the efficient MFCC quantization with a low-bit rate. First, we explore the interframe correlation of MFCCs, which results in the predictive quantization of MFCC. Second, a safety-net scheme is proposed to make the MFCC-based speech coder robust to channel error. As a result, we propose a 8.7 kbps MFCC-based CELP coder. It is shown from a PESQ test that the proposed speech coder has a comparable speech quality to 8 kbps G.729 while it is shown that the performance of speech recognition using the proposed speech coder is better than that using G.729.

  • PDF

A Study on Inverse Problem of Materials Forming Process using Optimization Technique and Distributed Computing (최적화 기법과 분산 컴퓨팅을 이용한 재료 성형공정의 역문제에 관한 연구)

  • Choi, Joo-Ho;Oh, Dong-Gil;Ha, Duk-Sik;Kim, Jun-Bum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.632-639
    • /
    • 2004
  • In this paper, an inverse problem of glass forming process is studied to determine a number of unknown heat transfer coefficients which are imposed as boundary conditions. An analysis program for transient heat conduction of axi-symmetric dimension is developed to simulate the forming and cooling process. The analysis is repeated until it attains periodic state, which requires at least 30 cycles of iteration. Measurements are made for the temperatures at several available time and positions of glass and moulds in operation. Heat removal by the cooling water from the plunger is also recorded. An optimization problem is formulated to determine heat transfer coefficients which minimize the difference between the measured data and analysis results. Significant time savings are achieved in finite difference based sensitivity computation during the optimization by employing distributed computing technique. The analysis results by the optimum heat transfer coefficients are found to agree well with the measured data.