• Title/Summary/Keyword: Generator stator

Search Result 338, Processing Time 0.023 seconds

Variable Gain Current Controller Considering Inductance Variations after the Connection of DFIG Stator to the Grid (DFIG 고정자의 계통연계시 인덕턴스 변동을 고려한 가변이득 전류제어기)

  • Shin, Soo-Cheol;Yu, Jae-Sung;Hong, Jung-Ki;Suh, In-Young;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.293-298
    • /
    • 2009
  • This paper presents a variable gain current control algorithm for the stabilized grid connection between the grid and a doubly fed induction(DFIG) as a wind power generator. The performance of a RSC current controller depends highly on accurate machine parameters, and especially requires a fast and robust response regardless of the disturbances such as voltage sag. However, parameter variations of a DFIG occur at the point of grid connection, which affects the current controller gains based on DFIG parameters after a DFIG is connected to the grid. Thus, performance degrades when actual machine parameters depart from values used in the control system. In the proposed algorithm, current controller gains of the rotor side converter(RSC) are changed after a DFIG is connected to the grid. The simulation results and experimental results for a 750kW are shown to illustrate the feasibility of the proposed algorithm.

Development of 800kW class Direct Drive Synchronous Generator for WECS (풍력발전기용 800kW급 직접구동형 발전기 개발)

  • Lee H. G.;Kim D. E.;Suh H. S.;Han H. S.;Jung Y. G.;Lee W. W.;Park K. H.;Chung C. W.;Lim M. S.;Oh M. S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.76-79
    • /
    • 2005
  • 포항풍력에너지연구소와 (주)보국전기는 에너지 관리공단의 지원으로 2002년부터 직접구동형 풍력터빈( KBP-750D) 에 사용될 발전기 개발을 시작하여 2005년 3월 개발을 완료하였다. KBP-750D에 사용되는 발전기는 증속을 위한 gearbox를 사용하지 않는 직접 구동형이고, 영구자석을 사용하여 여자하는 형식이다. 이런 특징은 풍력발전에서 요구하는 주요 요구조건인 고 효율, 고 신뢰성을 만족시키기 위해서 매우 중요하다. 개발된 발전기는 25 rpm 에서 800 kW의 정격을 가지도록 설계되었다. 공극 직경은 3,320mm 이며, stator의 길이는 705mm, 공극은 4.5mm 이고, 극수는 84이다. 또한 전체 중량은 약 22 ton이다. 이 논문에서는 발전기의 물리설계, 공학설계, 제작 및 시험결과에 관해서 기술한다.

  • PDF

Designs of 10 MW Air-core and Iron-core HTS Wind Power Generators

  • Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.545-550
    • /
    • 2015
  • High Temperature Superconducting (HTS) synchronous generators can be designed with either an air-core type or iron-core type. The air-core type has higher efficiency under rated rotating speed and load than the iron-core type because of the iron losses which may produce much heat. However, the total length of HTS wire in the air-core type is longer than the iron-core type because the generated magnetic flux density of the air-core type is low. This paper deals with designs of 10 MW air-core and iron-core HTS wind power generators for wind turbines. Fully air-core, partially iron-core, and fully iron-core HTS generators are designed, and various stator winding methods in the three HTS generators are also considered, such as short-pitch concentrated winding, full-pitch concentrated winding, short-pitch distributed winding, and full-pitch distributed winding. These HTS generators are analyzed using a 3D finite elements method program. The analysis results of the HTS generators are discussed in detail, and the results will be effectively utilized for large-scale wind power generation systems.

A Study of Adaptive Sliding Mode Observer for a Sensorless Drive System of SRM (SRM 센서리스 구동시스템을 위한 적응 슬라이딩 모드 관측기 연구)

  • Oh Ju-Hwan;Lee Jin-Woo;Kwon Byung-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.691-699
    • /
    • 2004
  • SRM(Switched Reluctance Motor) drives require the accurate position information of the rotor. These informations are generally provided by a tacho generator or digital shaft-position encoder These speed sensors lower the system reliability and require special attention to noise. This paper describes a new approach to estimating SRM speed from measured terminal voltages and currents for speed sensorless control. The described method is based on the sliding mode observer. The rotor speed and position observers are estimated by the adaptation law using the real and estimated currents. However, the conventional adaptive sliding mode observer based on the variable structure control theory has some disadvantages that the estimated values including the high-frequency chattering and the steady state error generated due to the infinite feedback gain chosen and the discontinuous control input. To reduce the chattering and steady state error, an integrator is also inserted in the sliding mode observer strategy. The described adaptive sliding mode observer decreases the vibration to the switching hyper-plane of the sliding mode by adding integrator. The described methodology incorporates the Lyapunov algorithm to drive the rotor speed and the stator resistance such that it can overcome the problem of sensitivity in the face of SRM parameter variation. Also, without any mechanical information. The rotor speed of SRM is obtained form adaptive scheme. The described method is verified through the simulation and experiment.

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Modeling And Simulation of the Switching Time Calculation When Starts Asynchronous Motors using Matlab Software (비동기모터 기동시 Matlab을 이용한 스위칭시간 계산의 모델링 및 시뮬레이션)

  • Bae, Cherl-O;Vuong, Duc-Phuc
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.73-73
    • /
    • 2011
  • In fact, asynchronous motors are used widely. Asynchronous motors which have large power (compared to the source supplies) is needed to start them in various methods. The theory of application reduced voltage to motor's stator or variable resistor fed rotor for the purpose of altering the motor's torque and power consumption characteristics is an idea that has existed for many years. These concepts have flourished mainly due to the need to limit torque and limited generator/power distribution capabilities. However, how can know exactly the time of switching steps with different types of motors as well as load characteristics is very difficult. This paper focuses on the design and development mathematical models of motor[1][2], load, ACB, asynchronous machine and then is implemented in SIMULINK in order to calculate this time, special on ships where power generation station is limited. The simulation results are both compared and discussed in detail so that it can apply to conclude the most suitable and applicable starting time for new system with various motors and load.

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일에서 부분방전 분석)

  • Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.

A Strategy on Adaptive Current PWM Inverter for Induction Motor (유도 전도기용 순시전류 추종형 PWM 인버터에 관한 연구)

  • 박철우;박성준;권순재;김광태
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.2
    • /
    • pp.56-61
    • /
    • 1992
  • This paper is reported on the simulation and test results of a constant flux vector control scheme of an induction motor without any speed detecting eqiupment, in which the adaptive current PWM inverter is used. The rotor speed is estimated form stator voltage, current and parameters of motor, and control algorithm in the system is performed with by micro processor. By comparing the waveform of input current of this system with that of the case with taco-generator, good agreement is observed except small ripple component. Experimental results which are acquired at start up and during acceleration/deceleration are quite similar to those of the simulation results.

  • PDF

Fabrication and test of 100 hp High Tc Superconducting Motor (100마력 고온초전도 모터 제작과 평가(I))

  • Sohn M.H.;Baik S.K.;Lee E.Y.;Kwon Y.K.;Kwon W.S.;Moon T.S.;Park H.J.;Kim Y.C.;Cho C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1118-1120
    • /
    • 2004
  • For the first time in Korea, a 100hp high Tc superconducting(HTS) motor has been designed, developed and successfully tested recently. The design was based on 2-dimensional electromagnetic field analysis of cylindrical coordinate. The field winding of rotor was wound with Bi-2223 tapes and tested after assembled with other rotor components. The stator had air-gap type armature windings which allow higher terminal voltage and more sinusoidal voltage waveform than conventional iron cored machines. Steady state open & short-circuit test and resistive load test were conducted also in generator mode. The fabrication and test results of this machine were discussed in this paper.

  • PDF

Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 패턴 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF