• Title/Summary/Keyword: Generation of heat

Search Result 1,817, Processing Time 0.027 seconds

Quantitative Study on the Effect of the Building Composition on the Urban Thermal Environment (건물군 조건이 도시 열환경에 미치는 영향에 관한 정량적 검토)

  • Yeo, In-Ae;Yoko, Kamata;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.180-183
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate was analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1)The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. (2)Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature.

  • PDF

Power generation characteristics of thermoelectric module for waste heat energy harvesting (폐열에너지 하베스팅을 위한 열전모듈 발전특성 연구)

  • Yun, Jin Chul;Ju, Jung Myoung;Hwang, Jong Hyun;Park, Seong Jin
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.184-189
    • /
    • 2016
  • Recently, due to limitation of $CO_2$ gas emission and increase of demand to reduce energy consumption, lots of researches are conducted to harvest wasted heat energy with a thermoelectric module to produce electricity by Seebeck effect. This study was conducted to analyze characteristics of the thermoelectric module to apply for a heat energy harvesting device. Thermoelectric module composed of bismuth telluride was tested with various temperature conditions to analyze thermoelectric behavior of the module. Power generation efficiency of the thermoelectric module for various temperature condition was analysed with both experimental and theoretical methods. From the results, an optimum condition to harvest wasted heat energy with the thermoelectric module more efficiently was proposed.

The Risk Assessment of Runway Reaction in the Process of Fridel-Crafts Acylation for Synthesis Reaction (화합물 합성반응 중 Fridel - Crafts Acylation 공정에서의 폭주반응 위험성평가)

  • Lee, Kwangho;Kim, Wonsung;Jun, Jinwoo;Joo, Youngjong;Park, Kyoshik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.24-30
    • /
    • 2021
  • Heat is generated during the synthesis and mixing process of chemical compounds due to a change in activation energy during the reaction. A runaway reaction occurs when sufficient heat is not removed during the heat control process within a reactor, rapidly increasing the temperature, reaction speed, and rate of heat generation inside the reactor. A risk assessment was executed using an RC-1 (Reaction Calorimeter) during Friedel-Crafts acylation. Friedel-Crafts acylation runs the risk of rapid heat generation during Active Pharmaceutical Ingredient (API) manufacturing; it was used to confirm the risk of a runaway reaction at each synthesis stage and during the mixing process. This study used experimental data to develop a safety efficiency improvement plan to control the risks of runaway and other exothermic reactions, which was implemented at the production site of a chemical plant.

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

The effect of drill design on stability and efficacy of dental implants (치과용 임플란트의 안전성과 유효성에 대한 드릴 디자인의 효과)

  • Yoon, Ji-Hoon;Jeon, Gye-Rok;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.132-142
    • /
    • 2015
  • Purpose : The objective of this research was to investigate an optimization of drill design factors for implant stability and efficacy through comparative evaluation by the cutting time, heat generation and initial stability. Materials and Methods : Three design factors were considered for the purpose of drill design optimization; the number of flute(2 flute, 3 flute), helix angle($15^{\circ}$, $25^{\circ}$) and drill tip shape(straight, 2-phase). Design factors were selected through comparative evaluation by temperature change, cutting time and ISQ value. Results : Heat generation and cutting time are influenced by all design factors(p<0.05). Drill tip shape was the only factors which influenced to the largest initial stability(p<0.05). Conclusion : Drills with 2 flutes, 2-phase formed drill tip, and 25 degrees of helix angle exhibit a better performance than other design.

Electro-thermal analysis of contacts and connections in VCB under high electric current by finite element methods (유한요소법에 의한 VCB 접속부의 대전류에 대한 전열해석)

  • Kang, Woo-Jong;Huh, Hoon;Kang, Kyeong-Rok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.715-722
    • /
    • 1998
  • A large electric system of a vacuum circuit breaker(VCB) has been studied for the electro-thermal analysis by finite element methods. Since the heat generation in VCB causes not only energy loss but deterioration of the VCB system with oxidization of parts, the overheating of the system must be prevented. For the analysis, a finite element formulation is derived for both electric analysis and thermal analysis that are coupled together. Two sets of formulations are uncoupled after finite dimensional approximation. First, the electric potential is obtained for the entire field and scaled to the given electric current. The electric field obtained is then used to calculate the heat generation in the VCB system including contacts and connections for the calculation of the temperature distribution in the entire domain. The finite element analysis is carried out to study the effect of shapes and locations of contacts and connections. From the results, the existing VCB has been modified to enhance its capacity with reduction of heat generation and temperature elevation.

Experimental Study on the Optimal Heat Exchanger of Thermoelectric Generation System for Industrial and Automobile Waste Heat Recovery (차량 및 산업설비 폐열회수용 열전발전시스템의 최적 열교환 시스템에 관한 실험적 연구)

  • Chung, Jae-Hoon;Kim, Woo-Chul;Lee, Jin-Ho;Yu, Tae-U.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.460-463
    • /
    • 2008
  • A large part of the overall industrial energy is dissipated as waste heat despite of much development in the utilization of thermal energy. A mean efficiency is reported to be only around 30 to 35%. The existing waste heat recovery technology has reached its limit and consequently, the development of a new technology is necessary. Improving efficiency using thermoelectric technology has recently come into the spotlight because of its unique way to recover thermal energy. In fact, thermoelectric generator directly converts thermal energy into electric energy by a solid state without any moving parts. Futhermore remarkable improvement in the thermoelectric energy conversion efficiency has been achieved. In this study, a thermoelectric generator was made using commercialized thermoelectric modules. With thermoelectric modules attached on a duct surface, hot air was blown into the duct using a hot air blower. On the other side of the module, a water jacket was attached to cool the module. With different air inlet temperatures and water flowrates, the electrical power of the thermoelectric generator was measured.

  • PDF

Multi-phase Accelerating Test Method of Thermal Aging Considering Heat Generation of Electric Equipment (전기기기의 발열을 고려한 다단계 가속열노화 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.18-23
    • /
    • 2013
  • Thermal aging test is performed to qualify the life time of equipment in thermally aged condition. Due to long life time more than 10 years like as in power plant, the equipment is subjected to the accelerated thermal aging condition which is able to shorten the long aging test period by increasing aging temperature. Normally, conservatism of thermal aging test causes to impose unbalanced and excessive thermal load on components of the equipment, and deformation and damage problems of the components. Additionally, temperature rise of each component through heat generation of the electric equipment leads to long-term problem of the test period. Multi-phase accelerating aging test is to perform thermal aging test in multiple aging conditions after dividing into groups with various components of equipment. The groups might be classified considering various factors such as activation energy, temperature rise, glass transition temperature and melting temperature. In this study, we verify that the multi-phase accelerating aging test method can reduce and equalize the thermal over load of the components and shorten aging test time.

Evaluation of the Grinding Performance of an Engine Block Honing Stone through Monitoring of Workload and Heat Generation (작업부하 및 발열 모니터링에 의한 엔진블록 호닝스톤 연삭성 평가)

  • Yun, Jang-Woo;Kim, Sang-Beom
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.69-75
    • /
    • 2019
  • Since gasoline engines are based on a combination of a cast iron liner and an aluminum block, which have different thermal properties and stiffnesses, bore shape distortion is likely to occur during honing due to uneven thermal deformation. To solve this problem, many tests and evaluations are needed to support the development of a high-performance honing stone with low heat generation. Moreover, performance evaluation, which depends on inspection and observation after work, often requires much trial and error to optimize tool design, due to challenges in the accurate interpretation of results. This study confirmed that the assessment of grinding capability was clarified by evaluating performance under severe work conditions and by in-situ measurement and recording of current consumption (workload) and heat generation during operation. As a result of using a honing stone with excellent grinding performance in engine block manufacture-in which cylinder bore distortion caused by thermal deformation during manufacture is a problem-a noticeable improvement in the degree of cylindricity was observed.

Calculating the Benefit of Distributed Combined Heat Power Generators from Avoiding a Transmission Expansion Cost by Solving a Mixed Integer Linear Programming (혼합 정수 선형 계획법 기반의 최적 경제 급전을 활용한 분산형 열병합 발전원의 송전선로 건설비용 회피 편익계산)

  • Kwon, Wook Hyun;Park, Yong-Gi;Roh, Jae Hyung;Park, Jong-Bae;Lee, Duehee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.4
    • /
    • pp.513-522
    • /
    • 2019
  • We calculate the benefit of distributed combined heat power generators from avoiding a transmission expansion cost by building distributed generators near electricity demand centers. We determine a transmission expansion plan by solving a mixed integer linear problem, where we modify capacities of existing transmission lines and build new transmission lines. We calculate the benefit by comparing the sum of generation and transmission expansion costs with or without distributed generators through two simulation frames. In the first frame, for the current demand, we substitute existing distributed generators for non-distributed generators and measure an additional cost to balance the generation and demand. In the second frame, for increased future demand, we compare the cost to invest only in distributed generators to the cost to invest only in non-distributed generators. As a result, we show that the distributed generators have at least 5.8 won/kWh of the benefit from avoiding the transmission expansion cost.