• Title/Summary/Keyword: Gate Operation

Search Result 822, Processing Time 0.024 seconds

A study on efficient gate system based RFID at the container terminal

  • Kim, Hyun;Kim, Yul-Seong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.4
    • /
    • pp.277-283
    • /
    • 2006
  • It is a world trend to construct large terminal and develop automated container terminal to attract Super Post-Panamax and provide service which is based on differentiation. In fact, there is insufficient research for automatization of terminal gate since the automatization of current constructed container terminal is only focused on increasing productivity and unmanned system through the automatization of quay, yard, etc. In this paper, we have investigated advantage/disadvantage of existing gate operation systems and compared each gate operation system in the aspect of raising terminal image and the productivity. For the specific study, we have used data from actual terminal gate operation and RFID model business sponsored by MOMAF (Ministry of Maritime Affairs and Fisheries). As a result, this paper carried out an efficient gate operation system and it has been expected that it will be performed as groundwork of automated gate operation system which is for design of container terminal and improvement of gate operation system.

A Study on Construction of Multiple-Valued Multiplier over GF($p^m$) using CCD (CCD에 의한 GF($p^m$)상의 다치 승산기 구성에 관한 연구)

  • 황종학;성현경;김흥수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.3
    • /
    • pp.60-68
    • /
    • 1994
  • In this paper, the multiplicative algorithm of two polynomials over finite field GF(($p^{m}$) is presented. Using the presented algorithm, the multiple-valued multiplier of the serial input-output modular structure by CCD is constructed. This multiple-valued multiplier on CCD is consisted of three operation units: the multiplicative operation unit, the modular operation unit, and the primitive irreducible polynomial operation unit. The multiplicative operation unit and the primitive irreducible operation unit are composed of the overflow gate, the inhibit gate and mod(p) adder on CCD. The modular operation unit is constructed by two mod(p) adders which are composed of the addition gate, overflow gate and the inhibit gate on CCD. The multiple-valued multiplier on CCD presented here, is simple and regular for wire routing and possesses the property of modularity. Also. it is expansible for the multiplication of two elements on finite field increasing the degree mand suitable for VLSI implementation.

  • PDF

A Study on the New Discharge AND Gate and Drive Scheme for the Cost Down of the PDPs (PDP의 가격절감을 위한 새로운 방전 AND Gate 및 구동기술에 관한 연구)

  • 염정덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.6
    • /
    • pp.267-273
    • /
    • 2003
  • The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.

Optimal Gate Operation and Forecasting of Innundation Area in the Irrigation Reservoir (관개저수지의 최적수문조작과 침수구역 예측)

  • 문종필;엄민용;김태철
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.486-492
    • /
    • 1999
  • One of the purpose of the reservoir operation is minimizing theinnudation area in the downstream reaches during flood period.l To execute the gate operation properly , it requires lots of real-time data such as rainfall, reservoir level, and water level in the downstrea. Gate operation model was developed with the flood discharge obtained from real-time flood forecasting model and the criterion prepared from the past history of gate operation. Water level in the downstream would be increased by the releasing discharge from the spillway and the area of paddy land flooded in a certain detph and time would be estimated usnig GIS map. Gate operation model was applied to the Yedang reservoir, and the flooded area, depth and time in the paddy land was estimaged.

  • PDF

A Study on the Discharge AND Gate of Plasma Display Panels (플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구)

  • 손현성;채승엽;염정덕
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

Water Quality Behavior by the Sluice Gate Operation of Freshwater Lake (배수갑문 방류시점 및 방류량에 따른 담수호의 수질변화)

  • 김선주;김성준;김필식;이창형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.1
    • /
    • pp.91-101
    • /
    • 2003
  • Boryeong Seadike located at southwestern seashore of Korean peninsula completed in 1997. Sluice gate operation can be an important factor to maintain lake water quality and reduce retaining time of pollutants within lake. The lake water quality simulation model, WASPS was adopted and tested to find out proper gate operation timing and discharge amount. From the simulation of sluice gate operation, the results showed that the later the time of discharge for loosing 1 day successively to 6 days, the better the quality of water. Discharge amount showed relatively minor changes of water quality. This means that pollutants flowed into lake from watershed do not have enough time to mix up with deep water when the gate opened at early time. About 3 days delay of discharge caused the dilution effect to stabilize the lake water quality in case of Boryeong freshwater lake.

Gate Operation Rule of Paldang Dam by Considering Discharge and Downstream Flow Pattern (방류량 및 하류부유황을 고려한 팔당댐의 수문조작기준 선정)

  • 서규우;이종설
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.209-219
    • /
    • 1996
  • The existing gate operation rule of Paldang hydroelectric plant has been used since the construction of the dam in 1973 except partial modification due to the construction of Chungju multipurpose dam in 1985. The water level near the downstream of Paldang dam has been lowered about 3 m because of the channel maintenance of Han River development project. Thus, the discharge estimation formula based on the submerged orifice type spillway has to be re-evaluated by considering various patterns of the gate operation rules and lowered channel bed. In this study, three types of gate openings were tested to select the proper gate operation rules through the hydraulic model test for various discharges and opening heights. Also, the numerical analysis has been performed to simulate the flow patterns of downstream. As a result, the gate operation rule, which opens 5 gates each time from the left side, was selected as the proper gate operation rule of Paldang dam.

  • PDF

A Study on Dynamic Water Quality Change for Gate Operation in Seonakdong River (서낙동강 수문 운영에 따른 동적 수질 변화 연구)

  • Kim, Jung Min;Kim, Young Do
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1401-1411
    • /
    • 2013
  • The inflow from Daejeo gate and the outflow from Noksan gate in Seonakdong river, which is a reservoir-like river with the characteristics of stagnant water, is very important for TMDLs (Total Maximum Daily Load) of Nakbon N unit watershed. However, there are very few measured data for calculating base flow. The operating data is much different from the actual measured data because the probable maximum flowrate is used for gate operation. In this study, the operating flowrate data of Daejeo and Noksan gates are compared with the monthly water quality data from Ministry of Environment monitoring station. The dynamic change of the flowrate and the water quality is also measured for the operation of Daejeo and Noksan gates. The flowrate of Seonakdong river is measured, which is affected by the gate operation, the water elevation difference of Nakdong river and Seonakdong river, and the tidal elevation. The results of this study can be used for establishing the water quality improvement measures by the optimal gate operation.

(Multiplexer-Based Away Multipliers over $GF(2^m))$ (멀티플렉서를 이용한 $GF(2^m)$상의 승산기)

  • Hwang, Jong-Hak;Park, Seung-Yong;Sin, Bu-Sik;Kim, Heung-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.35-41
    • /
    • 2000
  • In this paper, the multiplicative algorithm of two polynomals over finite field GF(2$^{m}$ ) is presented. The proposed algorithm permits an efficient realization of the parallel multiplication using iterative arrays. At the same time, it permits high-speed operation. This multiplier is consisted of three operation unit: multiplicative operation unit, the modular operation unit, the primitive irreducible operation unit. The multiplicative operation unit is composed of AND gate, X-OR gate and multiplexer. The modular operation unit is constructed by AND gate, X-OR gate. Also, an efficient pipeline form of the proposed multiplication scheme is introduced. All multipliers obtained have low circuit complexity permitting high-speed operation and interconnection of the cells are regular, well-suited for VLSI realization.

  • PDF

Normally-Off Operation of AlGaN/GaN Heterojunction Field-Effect Transistor with Clamping Diode

  • Han, Sang-Woo;Park, Sung-Hoon;Kim, Hyun-Seop;Lim, Jongtae;Cho, Chun-Hyung;Cha, Ho-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.2
    • /
    • pp.221-225
    • /
    • 2016
  • This paper reports a new method to enable the normally-off operation of AlGaN/GaN heterojunction field-effect transistors (HFETs). A capacitor was connected to the gate input node of a normally-on AlGaN/GaN HFET with a Schottky gate where the Schottky gate acted as a clamping diode. The combination of the capacitor and Schottky gate functioned as a clamp circuit to downshift the input signal to enable the normally-off operation. The normally-off operation with a virtual threshold voltage of 5.3 V was successfully demonstrated with excellent dynamic switching characteristics.