• 제목/요약/키워드: Gas-insulated switches

검색결과 10건 처리시간 0.022초

가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전의 측정 (Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch)

  • 길경석;박대원;최수연;김일권;박찬용
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.85-89
    • /
    • 2008
  • An objective of this paper is to develop a partial discharge (PD) measurement device for monitoring gas insulated switches installed in power distribution system. A capacitive voltage probe was studied and designed to detect PD pulse without an electrical connection. The PD measurement device consists of the capacitive voltage probe attached outside of a bushing, a coupling network which attenuates AC voltage by 270 dB, and a low noise amplifier with the gain of 40 dB in ranges of 500 kHz${\sim}$20 MHz. The sensitivity of the prototype device calculated by a calibrator was 1.98 m V /pc. An application experiment was carried out in a 25.8 kV gas insulated switch and the peak pulse of 76.7 pC was detected. From the experimental results, it is expected that the PD measurement device can be applied to online monitoring system of gas insulated switches.

가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전 측정 (Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch)

  • 최수연;박찬용;박대원;김일권;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.476-477
    • /
    • 2007
  • This paper described the partial discharge (PD) measurement techniques for diagnosing gas-insulated switches in overhead power distribution system. A capacitive voltage probe to detect PD pulse was designed and fixed on the surface of a bushing. We also designed a coupling network to attenuate AC voltage by 270 dB, and a low-noise amplifier having the gain of 40 dB and 500 kHz~20 MHz 3 dB. From the calibration, it was calculated that the sensitivity of the measurement system was 0.94mV/pC. In the application experiment, we could measure a PD pulse of 45 pC.

  • PDF

RF front-end Module for On-Line UHF Partial-discharge Monitoring System

  • Lee June Young;Kim Bok Ki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.776-779
    • /
    • 2004
  • A RF front-end module is designed for GIS(Gas Insulated Substation) which is employed for effective and efficient very high voltage transmission. Major advantage of the unit is improved PO detection sensitivity through minimizing the effect of surrounding interference signals, which is achieved by controlling the gain and the selection of the frequency band, for the precise detection of any UHF PO (Partial Discharge) disturbance occurred in the GIS due to some unwanted problems. For the development of the module, various switches for providing selected signal paths, wideband LNA, 3 BPF for selecting detection frequency band, and video detector are designed, fabricated and measured on 1 mm FR4 substrate with various RF components. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PO signals as low as 1 pC. It is believed that the value is enough to detect the signal occurred in GIS.

  • PDF

배전용 가스개폐기의 내 오손 성능향상 대책 (Anti-Contamination Capability of Gas Insulated Switch for Distribution Line)

  • 김주용;송일근;김찬영;한재홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.758-760
    • /
    • 1998
  • This paper provides the results of performance investigation of gas insulated switches(G/S) for distribution power system. In order to investigate anti-contamination capability of G/S we carried out electrical tests and material analysis on the body of G/S and it's accessories. Through this experiment we found out the lead cable of G/S had not anti-contamination capability and G/S had insufficient interval between each phase. In order to improve the performance of G/S for heavy contamination area it is indispensable to replace the lead cable to the new cable which has anti-contamination ability.

  • PDF

열경화성 에폭시를 이용한 가스 절연 개폐기용 절연 스페이서의 사출 성형 최적화 시뮬레이션 (Simulation for Injection Molding of Insulation Spacers for Gas-Insulated Switches Using Thermosetting Epoxy Resin)

  • 배재성;이원창;지홍섭;홍병유;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제34권6호
    • /
    • pp.426-432
    • /
    • 2021
  • Injection molding is used in many industrial fields such as home appliances, vehicle parts, and electronic device parts because various resins can be molded, leading to mass production of complex shapes. Generally, the empirical prediction method is used to set the initial processing conditions of injection molding. However, this approach requires a lot of cost and its presented solution is not accurate. In this paper, injection molding was simulated through the MoldflowTM in order to manufacture the spacer for gas insulated switch. Through the simulation, the flow of the resin with respect to the diameter of the inlet was analyzed. It was found that the process was possible at a higher resin temperature as the diameter of the inlet increased. In addition, through thermal analysis during injection of the resin, it was confirmed that a stagnation phenomenon occurred at the insert portion during injection molding, and the temperature of the resin was higher than that of the mold. As in this paper, if the spacer is manufactured by optimizing the injection hole and the temperature of the injection process based on simulation, it is expected that the spacer can be manufactured with high productivity.

국산 배전자동화시스템 구성설비의 보유기능 및 특성 (The Functions and Characteristics of Distribution Automation System Components)

  • 하복남;박상만;장정태;최태일;김호용;오상기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

도시철도 변전소 절연진단 프로그램 기술 분석 (An Analysis on Technology of Urban Railway Substation Insulation Diagnostic Program)

  • 박현준;박영;정호성;김형철;유기선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.116-116
    • /
    • 2010
  • This paper introduces an comprehensive monitoring and management program for implementation of a real-time monitoring system that monitors condition of urban railway AC/DC transformers, disconnecting switches, circuit breakers, regulators, and GIS (Gas Insulated Switchgear). Especially, the system is applied to diagnose the overall condition of urban railway substations by sending acquired data through an OPC server to a database, effectively storing and monitoring conditions simultaneously. The above system is a management based system and is also applicable to small-scale systems.

  • PDF

도시철도 변전소 전력설비 실시간 모니터링 방안 도출 (Derivation of Real-time Monitoring System for Power Supply System in Metro Substation)

  • 정호성;박영;어수영
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.333-337
    • /
    • 2010
  • This paper introduces an overall system design of a real-time monitoring system that monitors condition of urban railway AC/DC transformers, disconnecting switches, circuit breakers, regulators, and GIS (gas insulated switchgear). For effective diagnosis of urban railway facilities we developed optimized sensors and application technology. The proposed system is combined with wireless technology, implementing remote real-time monitoring of urban railway facilities. The derived real-time monitoring system for power facilities in urban railway substations will be applied not only to diagnose low voltage DC (direct current) railways but also to diagnose design of small power facilities of skyscrapers and apartments.

GIS에 있어서의 과도과전압(過渡過電壓) 측정용(測定用) 센서 (A Voltage Sensor for measurement of Very Fast Transients in GIS)

  • 이복희;백용현;하촌달치;서촌준언;석정승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 1990
  • The measurement of very fast transients generated by disconnecting switches in gas-insulated switchgear(GIS) have to deal with the problems such as reliability, interference pich-up, optimal design of high voitage equipments. This paper presents a new developed voltage sensor to measure the very fast transients, the basic theory of the measuring method, the design, structure of planar capacitive voltage probe are described. Finally the examples of modelling tests on an actual site GIS are discussed.

  • PDF

$SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성 (V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages)

  • 이복희;이경옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF