Accurate Prediction Method of Breakdown Voltage in Air at Atmospheric Pressure

  • Kim, Nam-Kyung;Lee, Se-Hee;Georghiou, G.E.;Kim, Dong-Wook;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.97-102
    • /
    • 2012
  • To predict accurately the breakdown voltage in air at atmospheric pressure, a fully coupled finite element analysis combining the hydrodynamic diffusion-drift equations with Poisson's equation is proposed in the current paper. As three kinds of charged transport particles are nonlinearly coupled with spatial electric fields, the equations should be solved by an iterative numerical scheme, in which secondary effects, such as photoemission and photoionization, are considered. The proposed method has been successfully applied to evaluate the breakdown voltage in circular parallel-plane electrodes. Its validity has been proved through the comparison of the predicted and experimental results. The effects of numerical conditions of the initial charge, photoemission, and background ionization on the discharge phenomena are quantitatively assessed through Taguchi's design of experiment method.

GIS 부분방전 검출을 위한 UHF 신호측정법 현장 적용 (Partial Discharge Detection on Site GIS Using UHF Technique)

  • 윤진열;박기준;구선근;조성훈;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1915-1917
    • /
    • 2000
  • Laboratory experiments and on site measurements were conducted to detect partial discharges in GIS(Gas Insulated Switchgear) using the UHF(Ultra High Frequency) technique that has been applied many places in the world. Experimental results were in good agreement with calculation in locating a partial discharge source using mock-up GIS. Defect type and its location were inferred after a measurement on 345 kV GIS that showed some abnormal phenomenon. Precise examination inside the GIS coincided with the results inferred from the measurement. High reliability of UHF technique for site application was confirmed.

  • PDF

신경망을 이용한 GIS 부분방전의 패턴인식 (Pattern recognition of GIS partial discharges using neural network)

  • 강윤식;이창준;강원종;이희철;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1812-1814
    • /
    • 2003
  • $SF_6$ 가스로 절연된 GIS(Gas Insulation Switchgears)는 매우 신뢰성이 높은 것으로 평가되어왔다. 그러나 GIS 내부에서 발생하는 결함에 대하여 완전하게 배제시키지 못하고 있으며, 이러한 부분방전 활동에 의한 대부분의 결함들이 GIS의 사고를 이끈다고 알려져 있다[1]. 따라서, GIS 내부에서 발생하는 부분방전 현상의 위치와 측정은 1940년대 초반부터 관심을 가져왔으며, 현재에는 부분방전 형태의 패턴이 사용된 부분방전 검출회로 및 신호의 전파와는 무관하다는 것을 알아낸 시점에 이르렀다. 이에 따라, 본 논문에서는 $SF_6$ 가스가 봉입된 GIS 내부에서 발생하는 부분방전 형태의 패턴인식을 위한 방법으로 NN(Neural Network)의 알고리즘 중 BP(Back-Propagation) 알고리즘을 이용하였다.

  • PDF

The water-energy-food resources and environment: Evidence from selected SAARC countries

  • Mansoor, Abdul;Sultana, Baserat;Shafique, Saima;Zaman, Khalid
    • Advances in Energy Research
    • /
    • 제6권1호
    • /
    • pp.1-15
    • /
    • 2019
  • The objective of the study is to examine the relationship between water resources, energy demand, food production, and environmental pollutants in selected SAARC nations, namely, Bangladesh, India, Pakistan, and Sri Lanka, during the period of 1990-2016. The results show that water, energy, and food (WEF) resources substantially affected air quality in the form of high mass carbon emissions, fossil fuel energy demand, methane discharges, nitrous oxide emissions, and greenhouse gas emissions in these countries. Food production and food deficit largely increase $CO_2$ emissions due to unsustainable production and malnutrition, while land use under cereal production increases $CH_4$ and $N_2O$ emissions. Electricity production escalates $CO_2$ emissions and fossil emissions across countries. The results support the carbon EKC hypothesis, while monotonic increasing function exists in case of fossil fuel energy. The study emphasizes the need to ensure environmental sustainability agenda by adopting cleaner production technologies in WEF resources.

온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성 (Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

RCP 기후변화 시나리오를 고려한 금강유역의 미래 용수공급 변화전망 (Water Supply Change Outlook for Geum River Basin Considering RCP Climate Change Scenario)

  • 노선희;정관수;박진혁;류경식
    • 한국수자원학회논문집
    • /
    • 제46권5호
    • /
    • pp.505-517
    • /
    • 2013
  • 본 연구에서는 기후변화에 따른 금강유역의 미래 유출량을 산정해 댐별 용수공급 변화량을 산정하였다. GCM은 최근 국립기상연구소가 도입한 영국기후변화 예측모델인 HadGEM2-AO를 사용하였고 새로운 온실가스 시나리오인 RCP시나리오를 금강유역내 기상관측소로 추출하였다. ArcSWAT모형을 이용해 1988년부터 2011년까지의 과거 유출모의를 수행하였으며 금강권역 내 대표 지점인 용담댐 및 대청댐 지점의 유입량과 최종 방류부의 유출량 분석값을 비교한 결과 모의치와 실측치가 각각 92.25%, 95.40%로 일치하는 것으로 나타나 모형의 적용성을 확인하였다. 또한 새로운 온실가스 시나리오하에서의 미래 유출량을 분석한 결과 RCP4.5 시나리오 하에서 평균 47.76%, RCP8.5 시나리오 하에서 평균 36.52%가량 유출증가가 일어날 것으로 예측되었으며 특히 가을철과 겨울철에 증가율이 높았다. 유출변화에 따른 용수공급 변화를 전망하기 위하여 KModSim으로 물수지 모형을 구축하여 추가 취수량 변화를 분석하였다. 이수안전도 95%유지조건 하에서 취수가능량을 분석한 결과, RCP4.5 시나리오 하에서 용담댐과 대청댐 각각 $9.41m^3/s$, $24.82m^3/s$가 더 취수가능하며 RCP8.5 시나리오 하에서는 $6.48m^3/s$, $21.08m^3/s$가 더 취수 가능한 것으로 전망되었다.

스팀 유동층 건조기를 이용한 고수분 저등급 석탄의 건조 특성 (Drying Characteristics of High Moisture Low Rank Coal using a Steam Fluidized-bed Dryer)

  • 김기영;이영우;박재혁;선도원;배달희;신종선;류호정;박재현
    • 청정기술
    • /
    • 제20권3호
    • /
    • pp.321-329
    • /
    • 2014
  • 본 연구에서는 고수분 저등급 석탄을 저수분 석탄으로 만들기 위하여 실험실 규모의 회분식 스팀 유동층 건조기를 사용하여 수분이 약 26%함유된 인도네시아산 저등급 석탄을 5% 이하로 건조하였다. 일반적으로 이산화탄소 포집 및 저장기술(carbon capture and storage, CCS)은 $CO_2$를 재생하는 공정에서 $100{\sim}150^{\circ}C$의 스팀과 $CO_2$혼합가스를 배출한다. 이때 배출되는 가스의 열을 사용하여 저등급 석탄을 건조하는 것이 본 연구의 최종 목적이다. 이를 위하여 본 연구에서는 건조의 열원으로 스팀을 사용하고, 유동화 가스는 $CO_2$를 사용하여 저등급 석탄을 건조하였다. 연구에 사용한 스팀의 유량은 0.3~1.1 kg/hr, 온도는 $100~130^{\circ}C$, 석탄의 층높이는 9~25 cm로 변화시켰다. 건조 후 석탄의 특성 변화는 공업분석, 발열량분석 그리고 입자크기 분석을 통하여 확인하였다. 변수 실험을 수행한 결과 원탄의 건조속도는 스팀의 유량과 온도가 증가함에 따라 증가하였고, 층높이가 감소할수록 건조속도가 증가하였다.

가스 센서용 ZnO, SnO2 박막의 이방성 식각을 위한 mask 재료의 식각 선택도 조사 (Etch selectivities of mask materials for anisotropic dry etching of gas sensing ZnO and SnO2 films)

  • 박종천;조현
    • 한국결정성장학회지
    • /
    • 제21권4호
    • /
    • pp.164-168
    • /
    • 2011
  • 고이온밀도 플라즈마 식각에 의한 고종횡비, 고이방성을 갖는 ZnO, $SnO_2$ 나노 구조 가스 감응층 형성을 위하여 mask 재료들과의 식각 선택도를 조사하였다. $25BCl_3$/10Ar ICP 플라즈마에서는 ZnO와 Ni 간 5.1~6.1 범위의 식각 선택도가 확보된 반면에 Al의 경우 효율적인 식각 선택도를 확보할 수 없었다. $25CF_4$/10Ar ICP 플라즈마에서는 ZnO와 Ni 간에 7~17 범위의 높은 식각 선택도를 얻을 수 있었다. $SnO_2$$SnF_x$ 식각 생성물의 높은 휘발성에 기인하여 Ni에 비해 매우 높은 식각 속도를 나타내었고, 최고치 약 67의 매우 높은 식각 선택도를 확보하였다.

O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각 (Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges)

  • 주영우;박연현;노호섭;김재권;이제원
    • 한국진공학회지
    • /
    • 제18권2호
    • /
    • pp.85-91
    • /
    • 2009
  • 현재 플렉시블 폴리머를 이용한 MEMS (Microelectromechanical Systems) 기술이 빠르게 발전하고 있다. 그 중에서 Polycarbonate (PC), Poly Methyl Methacrylate (PMMA)와 같은 플렉시블 폴리머 재료는 광학적 특성이 우수하고 인체 친화적이며 미세 패턴 제조 공정이 용이하다는 등의 많은 장점을 가지고 있다. 본 연구는 반응성 이온 식각 기술을 이용하여 $O_2$, $SF_6$ 그리고 $CH_4$의 삼성분계 가스의 혼합 비율에 따른 PC와 PMMA의 건식 식각 결과 및 특성 평가에 관한 것이다. 준비한 각각의 기판에 포토리소그래피 방법으로 마스크를 형성하여 샘플을 만들었다. RF 척 파워를 100 W, 총 가스 유량을 10 sccm으로 고정시켜 플라즈마 식각 실험을 실시하였다. 그 결과에 의하면 전체적으로 PMMA의 식각율이 PC보다는 약 2배 정도 높았다. 그 결과는 PC는 PMMA 보다 상대적으로 높은 녹는점을 가지고 있다는 사실과 관계가 있다고 생각한다. 또한 $O_2/SF_6/CH_4$의 삼성분계 가스와 $SF_6/CH_4$, $O_2/SF_6$, $O_3/CH_4$로 나누었을 때 $O_2/SF_6$의 혼합 가스에서 PMMA와 PC의 식각 속도가 가장 높았다 (PC: 5 sccm $O_2$/5 sccm $SF_6$에서 약 350 nm/min, PMMA: 2.5 sccm $O_2$/7.5 sccm $SF_6$에서 약 570 nm/min). SEM을 활용하여 식각된 표면을 분석한 결과 PC는 PMMA보다 상대적으로 식각 표면이 더 매끈하였다. 또한 표면 거칠기 분석결과 PC의 표면 거칠기는 1.9$\sim$3.88 nm이었지만 PMMA의 표면 거칠기는 17.3$\sim$26.1 nm로 현저하게 높았음을 확인할 수 있었다.

상압 플라즈마-촉매 하이브리드 반응기를 통한 CO2와 CH4의 전환처리 (Conversion of CO2 and CH4 through Hybrid Reactor Composed of Plasma and Catalyst at Atmospheric Pressure)

  • 김태경;누엔덕바;이원규
    • 공업화학
    • /
    • 제25권5호
    • /
    • pp.497-502
    • /
    • 2014
  • 상압 플라즈마 반응기 내에 Ni-$Al_2O_3$와 Ni-$MgAl_2O_4$ 촉매를 충진한 하이브리드 반응기를 이용하여 메탄과 이산화탄소의 전환반응을 진행하였다. 인가전력, 반응가스 유량, 혼합비율 및 반응기 온도 등 다양한 공정변수와 촉매의 충진 유무에 따른 메탄과 이산화탄소의 전환반응 특성이 분석되었다. 촉매의 반응 기여도 분석에서 공정온도를 $400^{\circ}C$까지 올린 경우에도 플라즈마 방전이 없이는 메탄과 이산화탄소의 촉매를 통한 자발적 전환반응이 일어나지 않았다. 이는 촉매를 충진하지 않은 플라즈마 방전만의 전환공정과의 비교를 통하여 확인할 수 있었다. 플라즈마 반응기에 촉매를 적용하는 경우에는 공정의 적절성과 전환처리에 적합한 촉매의 선택이 필수적이다.