• Title/Summary/Keyword: Gas discharge

Search Result 1,513, Processing Time 0.028 seconds

Numerical Analysis of Discharge Flow in Type III Hydrogen Tank with Different Gas Models (Type III 수소 저장 용기에서 가스 모델(gas model)에 따른 배출(discharge) 현상의 수치 해석적 연구)

  • KIM, MOO-SUN;RYU, JOON-HYOUNG;JUNG, SU YEON;LEE, SEONG WOO;CHOI, SUNG WOONG
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.6
    • /
    • pp.558-563
    • /
    • 2020
  • Hydrogen is attracting attention as an alternative energy source as an eco-friendly fuel without emitting environmental pollutants. In order to use hydrogen as an energy source, technologies such as hydrogen production and storage must be used, and new storage methods are being studied. In this study, the behavior of hydrogen in the storage tank were numerically studied under high-pressure hydrogen discharge conditions in a Type III hydrogen tank. Numerical results were compared with the experimental value and the results were quantitatively analyzed to verify the numerical implementation. With the results of pressure and temperature values under a given discharge condition, the Redich-Kwong gas model showed the adequate models with the smallest error between numerical and experimental results.

Discharge Properties of an AC-Plasma Display Panel

  • Sungkyoo Lim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Two kinds of the ac-plasma display panel (PDP) with the comb type and the matrix type electrodes were fabricated. The discharge properties were studied as a function of as species (Ne and Ne+He+Xe) and its pressure. The firing voltages (Vf) of the PDP with comb type electrodes were 159 V and 195 V under pure Ne and ne+He+Xe(68:30:2) gas mixture respectively. In case of PDP cell with the matrix type electrodes the Vf was increased to 200 V for pure Ne and 240 V for Ne+He+Xe gas mixture under the same gas pressure(300 mbar).

Discharge and Fire Extinguishing Test of Inert Gas Clean Agent (불활성 가스계 청정 소화약제의 방출 및 소화)

  • Song Eun-Seok;Kim Jae-Duck;Park Yang-Won
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.29-36
    • /
    • 2005
  • We carried out discharge and fire extinguishing tests of new inert gas clean agent, which consists of $92\%$ nitrogen and $8\%$ carbon dioxide, as an alternative of Halon that is banned by Montreal Protocol to protect the ozone layer of the earth. Discharge and fire extinguishing tests were performed in $27m^3$ and $190m^3$ rooms with piping which allows gaseous agent to transport from storage to test rooms. We confirmed that it took less than regulation time, 60 seconds for the discharge of over $95\%$ initial charged amounts. Discharge test variables were piping length and orifice size. Fire extinguishing tests verified that this new inert gas clean agent is suitable for both n-Heptane fire and deep seated fire of wood crib.

Analytical Application of Glow Discharge Atomic Absorption Spectroscopy (GD-AAS) Using Three Types of Jet Configurations Under Power Mode

  • Hwang, Jun Ho;Lee, Ki Beom;Kim, Min Su;Lee, Seong Ro;Kim, Hasuck;Kim, Hyo Jin;Lee, Gae Ho
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.443-448
    • /
    • 1995
  • Three anode configurations of six-jet, cone-jet and cylindrical-jet are tested for their analytical performance under power mode operation. The effect of pressure, power and gas flow rate on atomic absorption signals have been studied. The increase of atomic absorption signal of sample element is observed at a fixed pressure in all configurations as the gas flow rate increase up to 300-600 seem, and as the power dissipated in the glow discharge cell increase. The lower the pressure is in the glow discharge cell at a fixed discharge power and argon flow rate, the greater the absorbance of sample element is. The optimum conditions are taken from these data and a calibration curve of Cu in low-alloy steel sample is obtained. In this calibration curve, six-jet configuration shows the best analytical results varies as the sample element.

  • PDF

Analysis on DC Glow Discharge Properties of Ar Gas at the Atmosphere Pressure (대기압 Ar 가스의 직류 글로우 방전 특성분석)

  • So, Soon-Youl
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.417-422
    • /
    • 2010
  • Atmosphere Plasma of Gas Discharge (APGD) has been used in plasma sources for material processing such as etching, deposition, surface modification and so on due to having no thermal damages. The APGD researches on AC source with high frequency have been mainly processed. However, DC APGD studies have been not. In order to understand APGD further, it is necessary to study on fundamental properties of DC APGD. In this paper, we developed a one-dimensional fluid simulation model with capacitively coupled plasma chamber at the atmosphere pressure (760 [Torr]). Nine kinds of Ar discharge particles such as electron (e), positive ions ($Ar^+$, $Ar_2^+$) and neutral particles ($Ar_m^*$, $Ar_r^*$, $Ar_h^*$, $Ar_2^*$(1), $Ar_2^*$(3) and Ar gas) are considered in the computation. The simulation was worked at the current range of 1~15 [mA]. The characteristics of voltage-current were calculated and the structure of Joule heating were discussed. The spatial distributions of Ar DC APGD and the mechanism of power consumption were also investigated.

A Study on Discharge Characteristics from the Nozzle Orifice Attached to a Modularized Fire Extinguishing Gas-agent Container Under Horizontal Position (용기 일체형 가스소화 방식의 오리피스 방사 특성에 관한 연구)

  • 김윤증;윤명오;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.59-69
    • /
    • 2002
  • The conventional fire extinguishing gas-agent system has a configuration in which the gas-agent comes out of a cylindrical container having vertically settled shape. However, in this study a horizontally installed container of a piping shape having a cylinder of the same shape with a cylinder valve and a discharge nozzle was used, and the relationship between orifice size of nozzle and discharge rate of gas-agent was investigated through various experiments including the measurement of discharge rate under different ambient-temperature conditions. In such experiments, HCFC Blend A was used without super-pressurization by nitrogen. From this research, it was observed that statutory discharge duration of 10 seconds can be met if the relatively large size of the valve and the nozzle orifice were properly selected.

A Study on the Inflammable Gas Explosion Triggered by the Electric Discharge Static Eliminator on Voltage Application Type (전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구)

  • Lee Chun Ha;Ok Kyoung Jea;Kim Jum-Ho;Kwon Byung-Duck;Cha Ha-Na;Yun Kea Won
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.22-26
    • /
    • 2004
  • The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode.

A Study on Characteristics of The $CF_3I$-Xe Mixtures gases in a Plasma Discharge Simulation (플라즈마 방전 시뮬레이션에 의한 $CF_3I$-Xe 혼합 가스에서의 물성 특성 연구)

  • Shim, Eung-Won;Tuan, Do Anh;Jeon, Byung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1582-1583
    • /
    • 2011
  • Recently, it has been found that trifluoroiodomethane ( $CF_3I$) gas can replace $SF_6$ gas as a prospective substitute gas. For quantitative understanding of gas discharge phenomena, we should know electron collision cross sections and electron transport coefficients. Using electron collision cross sections of $CF_3I$ and Xe, we calculated elecron drift velocity, longitudinal coefficient, effective ionization coefficient in $CF_3I$-Xe mixtures using a two-term approximation of the Boltzmann equation. We also compared the electron transport coefficients in pure gas and those of 10%, 20%, 50%, and 70% $CF_3I$-Xe mixture gases. The present data may be showed appropriate ratios of $CF_3I$-Xe mixture gas for replacing the $SF_6$ gas.

  • PDF

Insulated Characteristics of PET Film under $SF_6$ ($SF_6$ 가스중 PET Film의 절연특성)

  • Kim, J.D.;Jung, J.G.;Joo, S.C.;Lee, D.J.;Park, J.Y.;Lee, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2120-2122
    • /
    • 1999
  • $SF_6$ gas has been widely used the gas insulated transmission line, gas insulated transformer and gas insulated substation and Polyester film used as the turn insulation with other material. $SF_6$ gas has been actively studied in domestic and foreign countries. In general, when dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents the insulation strength of turn insulation of $SF_6$-PET film studied under application of AC voltage, constitute of the plane to plane with PET Film. The results obtained in experimental are summarized that Partial Discharge Initial Voltage(PDIV) of turn insulation depend on gas pressure, but Breakdown Voltage(BDV) did not depend on gas pressure.

  • PDF

Application to Gas Sensors by Electron Emission from Carbon Nanotube Emitters (탄소나노튜브 전극으로부터 전계방출을 이용한 가스센서의 응용)

  • Kim Seong-Jeen
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.5
    • /
    • pp.405-410
    • /
    • 2006
  • We fabricated gas sensors using carbon nanotubes (CNTs) as electron emitters for the purpose of detecting inert gases. By using the silicon-glass anodic bonding and glass patterning technologies with the typical Si process, we improved the compactness of the sensors and the reliability in process. The proposed sensor, based on, an electrical discharge theory known as Paschen's law in principle, works by figuring the variation of the discharge current depending on gas concentration. In the experiment, the initial breakdown characteristics were measured for air and Ar as a function of gas pressure. As the result, even though it should be realized that there are many other factors which have an effect on the breakdown of a gap, the sensors led to similar result as predicted by Paschen's law, and they showed a possibility as gas sensors which enable to detect the gas density ranged to the vacuum pressure from 1 to $10^{-3}$ Torr.