• Title/Summary/Keyword: Gas Supply

Search Result 1,266, Processing Time 0.036 seconds

A Study on the Effect of Mobile CCTV Monitoring on Safety Risk Factors (안전 Risk 요인에 대한 이동형 CCTV 모니터링이 미치는 영향 연구)

  • Young Cheol Song;Tae-Gon Kim;Eunseok Lee;Tae-Hun Kim
    • Industry Promotion Research
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2024
  • Dangerous tasks that occur every day at industrial site manufacturing plants, which have recently been making rapid changes, were classified by type, and the effect of mobile circuit television (CCTV) on safety accidents among daily safety management methods was analyzed. The subject of the study is about 3,000 workers who manage the infrastructure facility sector to supply utilities such as gas, water, and electricity to the display manufacturing process located in Asan City, and the study was conducted based on the daily dangerous work from 2019 to 2022, and during this study period, many construction works such as new investment and expansion of construction and manufacturing processes were occurring at the site. As a result, the rate of safety accidents and exposure to risks are expanding, and most of the safety accidents occurred because the sectors that did not follow the basics and the safety measures on the site were not implemented. In this paper, it was confirmed that there is an accident reduction effect according to the relationship between the dangerous work classified according to the work importance and the mobile CCTV shooting rate. Considering the characteristics of the manufacturing plant site, it can be used to play the role of basic data for preventing safety accidents based on the expansion of the introduction of a new safety management culture in the future.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Effect of economic growth, industrial structure, efficiency improvement, decarbonization of power sector and fuel substitution for the transition to low carbon society by 2050 (2050년 저탄소 사회로의 전환을 위한 경제성장, 산업구조, 효율개선, 전력 탈탄소화와 연료 대체의 효과)

  • Park, Nyun-Bae;Hong, Sungjun;Park, Sang Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • This paper analyzed transition pathways toward a low carbon society in Korea to meet global $2^{\circ}C$ climate target. Lower economic growth, industrial structure change, enhance of energy demand management, decarbonization of power sector, and replacement of low carbon fuel could reduce greenhouse gas (GHG) emission from fuel combustion in 2050 by 67% against in 2011, or by 74% against in BAU (Business-As-Usual). Lower economic growth contributes to 13% of cumulative emission reduction relative to BAU, industrial structure change 9%, enhance of energy demand management 72%, decarbonization of power sector 5% and replacement of low carbon fuel 1% respectively. Final energy consumption in 2050 needs to be reduced to 50% relative to 2011, or to 41% relative to BAU. Nuclear, coal and renewable energy represent 31%, 40%, 2% respectively among electricity generation in 2011, but 38%, 2%, 32% in 2050. CCS represents 23% of total generation in 2050. Emission intensity of electricity in 2050 was decreased to 19% relative to 2011, or to 24% relative to BAU. Primary energy in 2050 was decreased to 64% compared to 2011, or to 44% compared to BAU. Final energy consumption, primary energy supply and GHG emission from fuel combustion from 1990 to 2011 increased by 176%, 197%, 146%. Radical change from historical trend is required to transit toward a low carbon society by 2050. Appropriate economic growth, structural change to non-energy intensive industries, energy technology research, development and deployment (RD&D) in terms of enhancement of energy efficiency and low carbon energy supply technologies, and fuel change to electricity and renewable energy are key instruments.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Mitigation of Greenhouse Gases by Water Management of SRI (System of Rice Intensification) in Rice Paddy Fields (논에서 SRI (System of Rice Intensification) 물 관리 방법을 적용한 온실가스 저감 효과)

  • Kim, Gun-Yeob;Lee, Seul-Bi;Lee, Jong-Sik;Choi, Eun-Jung;Ryu, Jong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1173-1178
    • /
    • 2012
  • Water competition among domestic, industrial and agricultural sectors has been gradually heightened recently in Korea as the lack of water supply is expected in the near future. About 46% of nation's water use is consumed in paddy farming to produce rice. And the conservation of water resource and quality in agricultural sector is a pending issue in the nation's long term water management plan. New paddy rice farming techniques that use significantly less irrigation water are urgently required. System of Rice Intensification (SRI) that is now well known to produce more rice with less water consumption has not been tried in Korea yet. And environmental effect of SRI on greenhouse gases (GHGs) has not been well investigated. The objective of this study was to measure the effect of SRI on GHGs as well as water use and rice yield in a Korean paddy condition. Three experimental runoff plots $5{\times}15m$ in size were prepared at an existing paddy field. Runoff, GHGs emission and water quality were measured during the 2011 growing seasons while a Japonica rice variety was cultivated. Rice plants grew better and healthier in SRI plots than in continuously flooded (CF) and intermittently drained (ID) plots. Rice yield from SRI plots increased 112.8 (ID)~116.1 (CF)% compared with CF and ID plots. Irrigation requirement of SRI plots compared to CF plot reduced by 52.6% and ID plot reduced by 62.0%, meaning that about 37.9~47.4% of irrigation water could be saved. GHGs emission from SRI plots reduced by 71.8% compared to that from CF plot and by 18.4% compared to that from ID plot, meaning that SRI could help contribute to ease the greenhouse gas accumulation in the atmosphere. It was believed that SRI is a promising paddy farming technique that could increase rice yield, and reduce irrigation water requirement and GHGs emission not just in Korea but also other rice farming countries all over the world. However, it was recommended that long term studies under different conditions including rice variety, soil texture, water source, climate need to be conducted for reliable data for the development of environmental policies related to GHGs emission control and management.

Removal of Mixed Gases of H2S and NH3 by the Biofilter Packed with Biomedia (Biomedia를 충전한 Biofilter에서 H2S와 NH3 혼합악취의 제거)

  • Lim, Joung Soo;Cho, Wook Sang;Lee, Eun Young
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2006
  • When ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) in binary mixture gases were supplied to a biofilter packed with biomedia made of polyurethane, PVA, and worm cast. No odor gases were detected on the outlet of the biofilter when $NH_3$ and $H_2S$ were separately supplied to the biofilter at space velocity(SV) of $50h^{-1}$ until inlet $NH_3$ concentration was increased up to 300 ppmv and inlet $H_2S$ to 428 ppmv. While, inlet $NH_3$ concentration maintained at 50 ppmv, inlet $H_2S$ concentration increased from 1 to 489 ppmv, and the removal efficiency of each gas was investigated. After that, $NH_3$ concentration increased step by step such as 80, 100, 200, 300, 400 and 500 ppmv. $H_2S$ concentration increased gradually when $NH_3$ concentration was set up at each condition. Under each condition, removal efficiency of $NH_3$ and $H_2S$ gas was investigated by analysing the gases sampled from the inlet and outlet of the biofilter. When binary gases were supplied to the biofilter and inlet $NH_3$ concentration was increased from 50 to 300 ppmv, elimination capacity of $NH_3$ increase linearly as inlet loading increased to $11.14g\;N{\cdot}m^{-3}{\cdot}h^{-1}$. However, as inlet $NH_3$ concentration increased over 300 ppmv, both removal efficiency and elimination capacity decreased while inlet loading increased. $H_2S$ removal efficiency was not affected seriously by the simultaneous supply of $NH_3$ when maximum inlet loading of $H_2S$ was under $40.27S{\cdot}m^{-3}{\cdot}h^{-1}$ and maximum inlet loading of $NH_3$ was under $15.25N{\cdot}m^{-3}{\cdot}h^{-1}$.

  • PDF

A Feasibility Study on Thermal Energy Resource in Deep Ocean Water (해양심층수 에너지자원 이용 타당성 분석 연구)

  • Kim, Jeong-Hyop;Kim, Gwang-Tae;Park, Se-Hun;Oh, Wee-Yeong;Kim, Hyeon-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2012
  • Annual power consumption of our country is positioned in the upper percentile in the world, and because the proportion of fossil power generation is high, which ranks the 10th $CO_2$ emission country. In this regard, government has established and is implementing the National Energy Basic Plan to realize to get out of fossilization in energy supply while focusing on securing the technology for renewable energy as well as its commercialization in order to reduce greenhouse gas. Resource recovery technology for deep seawater thermal energy which is one of renewable energies is newly getting attention domestically as well as in overseas for securing resources and environmental improvement as a core technology for multilateral use of marine resources for low carbon and green growth. Economic feasibility analysis was conducted for the research and development as follows on the use of ocean thermal energy conversion and seawater air conditioning. First, in the case of power generation using deep seawater and warm discharge water from ocean thermal energy conversion plant of 1MW level, it is judged that the economic feasibility is insufficient but the feasibility will be significantly improved if we consider not only power generation but also drinking water and certified emission reduction by developing the power plant to the size for commercialization. Second, the economic feasibility for the use of deep seawater as air conditioning for the power plant of 1,000RT level turned out to be very good. Especially, when we consider certified emission reduction, it will be possible to secure sufficient economic feasibility. When we use it in connection with ocean thermal energy conversion, water conversion and agricultural and fishery use, it is judged that economic ripple effect will be significant and therefore it will be necessary to conduct research and development for early commercialization, distribution and diffusion of deep seawater energy.

A study on the introduction of organic waste-to-energy incentive system(I): Precise monitoring of biogasification (유기성폐자원에너지 인센티브제도 도입방안 연구(I): 바이오가스화 정밀모니터링)

  • Kwon, Jun-Hwa;Moon, Hee-Sung;Lee, Won-Seok;Lee, Dong-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.67-76
    • /
    • 2021
  • Biogasification is a technology that produces environmentally friendly fuel using methane gas generated in the process of stably decomposing and processing organic waste. Biogasification is the most used method for energy conversion of organic waste with high moisture content, and is a useful method for organic waste treatment following the prohibition of direct landfill (2005) and marine dumping (2013). Due to African Swine Fever (ASF), which recently occurred in Korea, recycling of wet feed is prohibited, and consumers such as dry feed and compost are negatively recognized, making it difficult to treat food waste. Accordingly, biogasification is attracting more attention for the treatment and recycling of food waste. Korea's energy consumption amounted to 268.41 106toe, ranking 9th in the world. However, it is an energy-poor country that depends on foreign imports for about 95.8% of its energy supply. Therefore, in Korea, the Renewable Energy Portfolio Standard (RPS) is being introduced. The domestic RPS system sets the weight of the new and renewable energy certificate (REC, Renewable energy certificate) of waste energy lower than that of other renewable energy. Therefore, an additional incentive system is required for the activation of waste-to-energy. In this study, the operation of an anaerobic digester that treats food waste, food waste Leachate and various organic wastes was confirmed. It was intended to be used as basic data for preparing the waste-to-energy incentive system through precise monitoring for a certain period of time. Four sites that produce biogas from organic waste and use them for power generation and heavy gas were selected as target facilities, and field surveys and sampling were conducted. Basic properties analysis was performed on the influent sample of organic waste and the effluent sample according to the treatment process. As a result of the analysis of the properties, the total solids of the digester influent was an average of 12.11%, and the volatile solids of the total solids were confirmed to be 85.86%. BOD and CODcr removal rates were 60.8% and 64.8%. The volatile fatty acids in the influent averaged 55,716 mg/L. It can be confirmed that most of the volatile fatty acids were decomposed and removed with an average reduction rate of 92.3% after anaerobic digestion.

The Patterns of CH4 and N2O fluxes from used Litter Stockpile from Korean Native Cattle (Hanwoo) (사용한 한우 깔짚에서 배출되는 CH4 및 N2O의 배출 특성)

  • Park, Kyu-Hyun;Choi, Dong-Yoon;Yoo, Yong-Hee
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.145-150
    • /
    • 2012
  • This study was conducted to measure methane ($CH_4$) and nitrous oxide ($N_2O$) emissions from the 6 month old litter stockpile used for korean native cattle (Hanwoo) from August 3, 2007 to October 4, 2007. Daily mean $CH_4$ emissions was peaked to 273.013 ${\mu}g\;m^{-2}\;s^{-1}$ (SE : ${\pm}1.047{\mu}g\;m^{-2}\;s^{-1}$) on first day and then gradually decreased to 2.309 ${\mu}g\;m^{-2}\;s^{-1}$ (SE : ${\pm}0.061{\mu}g\;m^{-2}\;s^{-1}$) at the end of this experiment. Daily mean $N_2O$ emissions was as little as 0.269 ${\mu}g\;m^{-2}\;s^{-1}$ (SE : ${\pm}0.018{\mu}g\;m^{-2}\;s^{-1}$) on first day, but exponentially increased up to 3.569 ${\mu}g\;m^{-2}\;s^{-1}$ (SE : ${\pm}0.454{\mu}g\;m^{-2}\;s^{-1}$) on 43rd day and then slowly decreased to 1.888 ${\mu}g\;m^{-2}\;s^{-1}$ (SE : ${\pm}0.012{\mu}g\;m^{-2}\;s^{-1}$) at the end of this experiment. Carbon dioxide equivalent ($CO_2$-eq), calculated by global warming potentials of $CH_4$ or $N_2O$, of $CH_4$ on first day occupied approximately 99% of sum of $CO_2$-eq of $CH_4$ and $N_2O$. Methane emissions decreased and $N_2O$ emissions increased so that $CO_2$-eq ratio of $CH_4$ to $N_2O$ was 50:50 on 34th day. The effect of $N_2O$ on the ratio was increase thereafter. The ratio of daily mean $CH_4$ and $N_2O$ emissions to daily error of the mean was calculated to find daily fluctuation of $CH_4$ and $N_2O$ emissions. The ratio of $CH_4$ was less than 1.0% till 11th day but increased to 10.9% on 57th day. The ratio of $N_2O$ (0.4%~51.0%) was higher than that of $CH_4$, showing high in early stage and then gradually decrease, which was different from the pattern of $CH_4$. The ratio of daily mean emissions to daily error of the mean was little in case of active $CH_4$ or $N_2O$ generation period, which would be caused by the temporal and spatial heterogeneity of composting process. Hence more air supply on early stage to decrease $CH_4$ generation and proper turning to reduce spatial heterogeneity are needed to mitigate greenhouse gas emissions.