• Title/Summary/Keyword: GMR-SV (giant magnetoresistance-spin valve)

Search Result 19, Processing Time 0.017 seconds

Rotation Effect of In-plane FM layer on IrMn Based GMR-SV Film

  • Khajidmaa, Purevdorj;Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • The magnetoresistance (MR) properties of antiferromagnetic (AFM) IrMn based giant magnetoresistance-spin valve (GMR-SV) was investigated in view point of the artificial rotation effect of ferromagnetic (FM) layer in the plane induced by an applied field during the post annealing temperature. The MR curves measured with an azimuthal angle region of ${\phi}=0^{\circ}-360^{\circ}$ are depended on the annealing temperature and the magnetization easy axis of two free NiFe layers and two pinned NiFe layers in dual-type GMR-SV film. Especially, the annealing temperature and sample rotation angle(${\theta}$ ) maintained to the magnetic sensitivity (MS) of 1.4 %/Oe with an isotropic region angle of $110^{\circ}$ are $100^{\circ}C$ and $90^{\circ}$, respectively.

Detection of Magnetic Nanoparticles and Fe-hemoglobin inside Red Blood Cells by Using a Highly Sensitive Spin Valve Device

  • Park, Sang-Hyun;Soh, Kwang-Sup;Hwang, Do-Guwn;Rhee, Jang-Roh;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.30-33
    • /
    • 2008
  • A highly sensitive, giant magnetoresistance-spin valve (GMR-SV) biosensing device with high linearity and very low hysteresis was fabricated by photolithography. The detection of magnetic nanoparticles and Fe-hemoglobin inside red blood cells using the GMR-SV biosensing device was investigated. When a sensing current of 1 mA was applied to the current electrode in the patterned active devices with an area of $2{\times}6{\mu}m^2$, the output signals were about 13.35 mV. The signal from even one drop of human blood and nanoparticles in distilled water was sufficient for their detection and analysis.

Post Annealing Treatment Introducing an Isotropy Magnetorsistive Property of Giant Magnetoresistance-Spin Valve Film for Bio-sensor (바이오센서용 거대자기저항-스핀밸브 박막이 등방성 자기저항 특성을 갖게 하는 후열처리 조건 연구)

  • Khajidmaa, P.;Park, Kwang-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.98-103
    • /
    • 2013
  • The magnetic easy axis of the ferromagnetic layer for the dual-type GMR-SV (giant magnetoresistance-spin valve) having NiFe/Cu/NiFe/IrMn/NiFe/Cu/NiFe multuilayer structure controlled by the post annealing treatment. The magnetoresistive curves of a dual-type IrMn based GMR-SV depending on the direction of the magnetic easy axis of the free and the pinned layers are measured by the different angles for the applied fields. By investigating the switching process of magnetization for an arbitrary measuring direction, the optimum annealing temperature having a steady and isotropy magnetic sensitivity of 2.0 %/Oe was $105^{\circ}C$. This result suggests that the in-plane orthogonal magnetization for the dual-type GMR-SV film can be used by a high sensitive biosensor.

Observation of Water Level and Temperature Properties by using a Giant Magnetoresistance-Spin Valve Film

  • Choi, Jong-Gu;Park, Kwang-Jun;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.214-218
    • /
    • 2012
  • The water level and temperature properties for the cooling system of potassium titanyl phosphate laser systems were observed. The middle point of the GMR-SV magnetoresistance curve is set in the neighborhood of high magnetic sensitivity (2.8 %/Oe). The experimental results for resistance dependence on water height and temperature showed linear regions with rates of 0.4 ${\Omega}/mm$ and 0.1 ${\Omega}/^{\circ}C$, respectively. The proposed results were found to be for adjusting the water level and temperature in the laser cooling system.

Regional Distribution of Isotropy Magnetic Property of Dual-type Giant Magnetoresistance-Spin Valve Multilayer (이중구조 거대자기저항-스핀밸브 박막의 자기등방성 영역분포에 관한 연구)

  • Khajidmaa, Purevdorj;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.193-199
    • /
    • 2013
  • The regional distribution of magnetic isotropy depending on the post annealing condition for the dual-type structure GMR-SV (giant magnetoresistance-spin valve) of NiFe/Cu/NiFe/IrMn/NiFe/Cu/NiFe multilayer was investigated. The rotation of in-plane ferromagnetic layer induced by controlment of the post annealing temperature inside of the vacuum chamber. The magnetoresistive curves of a dual-type IrMn based GMR-SV depending on the direction of the magnetization easy axis of the free layer and the pinned layer are measured by between $0^{\circ}$ and $360^{\circ}$ angles for the applied fields. The optimum annealing temperature having a steady and isotropy magnetic sensitivity of 1.52 %/Oe was $107^{\circ}C$ in the rotational section of $0{\sim}90^{\circ}$. By investigating the switching process of magnetization for an arbitrary measuring direction, the in-plane orthogonal magnetization for the dual-type GMR-SV multilayer can be used by a high sensitive biosensor for detection of magnetized micro-beads.

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device (마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구)

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of $RBC+{\mu}Beads$ is controlled by the electrical AC input signal. The $RBC+{\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

Uniaxial Magnetic Anistotropy of a NiO-Spin Valve Device

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • The shape anisotropy effect of a giant magnetoresistance-spin valves (GMR-SV) device with a glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe layered structure for use in the detection of magnetic property of molecules within a cell was investigated. The patterned device was given uniaxial anisotropy during the sputtering deposition and vacuum post-annealing, which was performed at $200^{\circ}C$ under a 300 Oe magnetic field. The pattern size of the device, which was prepared through the photolithography process, was $2{\times}15\;{\mu}m^2$. The experimental results confirmed that the best design for a GMR-SV device to be used as a biosensor is to have both the axis sensing current and the easy axis of the pinned NiO/NiFe/CoFe triple layer oriented in the direction of the device's width, while the easy axis of the free CoFe/NiFe bilayer should be pointed along the long axis of the device.

Properties of Exchange Bias Coupling Field and Coercivity Using the Micron-size Holes Formation Inside GMR-SV Film (GMR-SV 박막내 미크론 크기의 홀 형성을 이용한 교환결합세기와 보자력 특성연구)

  • Bolormaa, Munkhbat;Khajidmaa, Purevdorj;Hwang, Do-Guwn;Lee, Sang-Suk;Lee, Won-Hyung;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.117-122
    • /
    • 2015
  • The holes with a diameter of $35{\mu}m$ inside the GMR-SV (giant magnetoresistance-spin valve) film were patterned by using the photolithography process and ECR (electron cyclotron resonance) Ar-ion milling. From the magnetoresistance curves of the GMR-SV film with holes measuring by 4-electrode method, the MR (magnetoresistance ratio) and MS (magnetic sensitivity) are almost same as the values of initial states. On other side hand, the $H_{ex}$ (exchange bias coupling field) and $H_c$ (coercivity) dominantly increased from 120 Oe and 10 Oe to 190 Oe and 41 Oe as increment of the number of holes inside GMR-SV film respectively. These results were shown to be attributed to major effect of EMD (easy magnetic domian) having a region positioned between two holes perpendicular to the sensing current. On the basis of this study, the fabrication of GMR-SV applying to the hole formation improved the magnetoresistance properties having the thermal stability and durability of bio-device.

Fabrication and Characteristics of a Highly Sensitive GMR-SV Biosensor for Detecting of Micron Magnetic Beads (미크론 자성비드 검출용 바이오센서에 대한 고감도 GMR-SV 소자의 제작과 특성 연구)

  • Choi, Jong-Gu;Lee, Sang-Suk;Park, Young-Seok
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.173-177
    • /
    • 2012
  • The multilayer structure of glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(t nm)/NiFe(3 nm)/FeMn(12 nm)/Ta(5.8 nm) as typical GMR-SV (giant magnetoresistance-spin valve) films is prepared by ion beam sputtering deposition (IBD). The coercivity and magnetoresiatance ratio are increased and decreased for the decrease of Cu thickness when the thickness of nonmagnetic Cu layer from is varied 2.2 nm to 3.0 nm. It means that the decrease of non-magntic layer is effected to the interlayer exchange coupling of pinned layer and the spin configuration array of free layer. For experiment of detecting and dropping of magnetic beads we used the GMR-SV sensor with glass/Ta/NiFe/Cu/NiFe/FeMn/Ta structure. From the comparison of before and after for the dropping status of magnetic bead, the variations of MR ratio, $H_{ex}$, and $H_c$ are showed 0.9 %, 3 Oe, and 2 Oe, respectively. The fabrication of GMR-SV sensor was included in the process of film deposition, photo-lithography, ion milling, and MR measurement. Further, GMR-SV device can be easily integrated so that detecting biosensor on a single chip becomes possible.

Characteristics of GMR-SV Sensor for Measurement of Mineral Contents in Edible Water

  • Kim, Da-Woon;Lee, Ju-Hee;Kim, Min-Ji;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.14 no.2
    • /
    • pp.80-85
    • /
    • 2009
  • The mineral dissolution sensor system using GMR-SV and glass/Mg(200 nm) was prepared and characterized. The magnetic field sensitivity of GMR-SV to microscopic magnetic variation was about 0.8%/Oe. The change that occurs when Mg-film dissolves in water, the solubility of water, which is one of the basic properties of mineral water, was sensed by measuring the subtle variation of an electric current. In the case of edible water with Mg mineral added, bubbles were generated on the surface of the Mg film in the first 45 minutes, and the number of drops that were dissolved more rapidly than with the tap and DI waters later reduced to zero. For the edible water samples that each had different mineral Mg concentrations, the Mg solubility speed significantly differed. After injecting Mg film into the edible water, the magnetoresistance of the output GMR-SV signal decreased from a maximum of $45.4\;{\Omega}$ to a minimum of $43.6\;{\Omega}$. The measurement time was within 1 min, giving the rate of change ${\Delta}R/{\Delta}t=0.18\;{\Omega}/s$. This measurement system can be applied to develop a mineral Mg solubility GMR-SV sensor that can be used to sense the change from edible water to reduced alkali.