• Title/Summary/Keyword: GIC circuit

Search Result 9, Processing Time 0.027 seconds

A Study on the GIC Circuit and Its Application (GIC 회로 및 그 응용에 관한 연구)

  • 이영근
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.3
    • /
    • pp.9-16
    • /
    • 1972
  • In this article it is shown that a GIC circuit with conversion "s" can be realized and a inductor is realized as a RC active two terminal network by using it instead of a gyrator. It is also shown that arbitary stable transfer functions can be realized as the open-circuit voltage ratio of 2 port networks which include GIC;s. In relizing the GIC circuit using transistors, it is made clear that the nullatornorator model of atransistor can be successfully applied at least in the frequency range below 10kHz. The synthesis method using GIC's is characterized with the followings; First, arbitrary stable transfer functions are realized systematically by repeating very simple network structure. Second, in the overall network all circuit elements except GICs are only resistors. Third, the number of condensers in the overall network necessary for realizing the transfer function of n-th order are n, which is believed to be the least number expected. expected.

  • PDF

A Study on the Design of Active Filters Using Current Conversion Type Generalized Immittance Converter (전류변환 GIC를 사용한 능동 여파기의 설계 연구)

  • 심수보
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.2
    • /
    • pp.14-21
    • /
    • 1981
  • This paper describes a method for realizing RC active filters, by the use of the CGIC's In realizing the CGIC circuit, every element in the circuit is selected so as to minimize the effect of the non -ideal characteristic of operational amplifers, and an extra element is added to the, CGIC circuit to compensate the parasitic capacitances of the circuit. The CGIC s are utilized in the design of active filters using ladder embedding technique. The design procedure is presented in detail and the application is illustrated by the design of a band-pass filter of high order.

  • PDF

Realiztion of Transfer functions Unsing Current cnversion GIC's (전류변환 GIC에 의한 전달함수실현방식)

  • 이태원
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.3
    • /
    • pp.36-41
    • /
    • 1974
  • Two realigation procedures of any open-circuit transfer functions are presented through the use of genera1ized immitance converters composed of two operational amplifiers and passive elements. The fast precedure is to select the admittance conversion, h(s), to be k/s , and the second one to be k/s. The merit of the second procedure is the elimination of capacitors in passive networks, however, requires more CGIC's than the first. The second-order transfer function is realiged in the two methods under discussion to find that the sensitivity of Q factor and the undamped oscillation frequency to the variation of circuit elements. The first procedure proved to be favorable from the view point of sensitivities.

  • PDF

Frequency Controllable Wide-Beam Ultrasonic Transducer with Transverse Mode (압전 횡효과를 이용한 무지향성 주파수가변 초음파트랜스듀서)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol;Kang, Kab-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.417-423
    • /
    • 2004
  • In order to obtain wide-beam characteristics and variable resonant frequency of a ultrasonic transducer for the array source, an electrode of transverse mode piezoelectric vibrator is divided, and an electronic inductance is connected to the divided electrodes. The electronic inductance is made by GIC (General Impedance Converter) circuit. Because the GIC circuit is made of OP-Amps and other passive elements, the value of the inductance can be selected easily. As the results, the electronic inductance is variable in the range from 0.2 mH to 1.2 mH. Using the inductance, the resonance frequency of the transducer can be changed in the range from 73 kHz to 86 kHz. In the directivity of the transducer, it is confirmed that the beam width of the transducer is wider than $80^{\circ}$ at -3 dB in water.

Clamped capacitance control of a piezoelectric single crystal vibrator using a generalized impedance converter circuit (범용 임피던스 변환회로를 이용한 압전 단결정 진동자의 제동용량 제어)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.46-52
    • /
    • 2018
  • The piezoelectric single crystals used in piezoelectric transformers have a problem that power transfer capacity is comparatively low due to their high input impedance. In this study, we suggest a method to improve the power transfer capacity by reducing the high input impedance of the piezoelectric single crystal vibrator by connecting a capacitance increasing circuit to the electrical terminals of the piezoelectric single crystal vibrator where the circuit is a GIC (Generalized Impedance Converter) circuit using operational amplifiers. The result of measuring driving characteristics after applying the designed capacitance increasing circuit to the $128^{\circ}$ rotated Y-cut $LiNbO_3$ crystal vibrator confirmed that the input impedance decreased by 25 %, electromechanical coupling factor increased by 30 %, and the power transfer capacity increased by about 17 to 30 times in voltage conversion characteristics.

The Method for Harmonics Elimination of a Single Phase Current by the Analog Relay Control Circuit and Passive Filters (릴레이 구동회로 및 수동필터를 이용한 단상 전원의 부하 적응형 고조파 전류 제거 기법)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin;Choi, Won-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.6
    • /
    • pp.292-298
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to eliminate harmonic currents of nonlinear load and can also improve the power factor. They are not often optimal filters because the passive filters are designed under the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. We presents the new control method of passive filter selection type with the relay control circuit which is consist of analog GIC, comparater, flip-flop and etc. By the experimental results using the proposed system for the rectifier load, we concluded that the researched method is cost effective and the performance is better than the passive filter.

A Study of the Current Reference Signal Generation Circuit for Single-Phase Harmonic Elimination Systems (단상 전원 고조파 제거 시스템을 위한 기준전류 생성회로에 대한 연구)

  • Jung Done-youl;Park Chong-yeon;Kim Sang-hun;Choi Won-ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.335-342
    • /
    • 2005
  • This paper presents a circuit to generate the current reference signal for single-phase harmonic elemination systems. Some of conventional methods for the current reference signal generation based on neural network algorithms. It requires complex circuitry to implement. the simplest method is to use analog filters. but it is difficult to obtain good current reference signals. So, we propose the harmonic detection circuit using GIC(Generalized Impedance Converter) for the purpose of low cost ,simple circuitry and high performance, Simulation and experimental results verify that the proposed circuit has better harmonic detection performance than conventional circuit.

The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads (비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현)

  • Jang, Mok-Soon;Lee, Hu-Chan;Kim, Sang-Hoon;Park, Jong-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

The harmonics detection system adapting the variation of source frequency (전원 주파수 변동에 적응하는 고조파 검출 시스템)

  • Hwang, Hwan-Young;Choi, Won-Ho;No, Kyung-Ho;Park, Chong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.195-197
    • /
    • 2005
  • This paper proposed the new harmonic detection system for the source current with the large frequency variation. The harmonic detection system is designed of the analog circuit and is composed of a low pass filter, a DC-level converter using the PLL, the Voltage controlled GIC.

  • PDF