• 제목/요약/키워드: Fuel Cell Temperature

검색결과 933건 처리시간 0.033초

건물용 연료전지 복합배기구조 안전 실증평가 (An Empirical Evaluation of Safety of the Common Vent Structure for Stationary Fuel Cell Systems)

  • 이은경;이정운;문종삼;이성희;신동훈
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.596-605
    • /
    • 2018
  • Interest in hydrogen, as an energy carrier, has been growing to solve the problems on shortage of fossile fuels and greenhouse gas. According to the standard KGS FU 551 for stationary fuel cell installation, the fuel cell system could be connected up to two common exhausts to one floor. depending on the required power for building or the installation environment in buildings, multiple fuel cell systems could be installed. Afterwards the number of perforations and flues could be decided. Hence, economic efficiency in significantly determined with respect to installation area and the number of fuel cell systems. In addition, the complexity of common vent structure for stationary fuel cell systems could be changed. In this paper, Verification experiments were conducted by connecting the common exhaust system to the fuel cell simulation system and the actual fuel cell system. Humidity and temperature were changed at ON/OFF, but no factors were found to affect performance or system malfunction. Exhaust emissions were also measured to obtain optimized values. We intend to expand the diffusion of stationary fuel cells by verifying safety of common exhaust structure.

연료전지와 리튬 이차전지의 하이브리드 시스템 개발 (Development of hybrid system with fuel cell and lithium secondary battery)

  • 황상문;정은미;손동언;심태희;송하영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.143.2-143.2
    • /
    • 2010
  • Therefore, with this development assignment we'd like to develop the hybrid system combining 800W DMFC (Direct Methanol Fuel Cell) and 1.6kW of Lithium secondary battery pack which can be applied to the most common small cart. a scooter, to secure the development capability of hundreds of Watts DMFC, the high-capacity Lithium secondary battery pack, the technology of BMS (Battery Management System) and the development technology of hybrid system. DMFC, in fact, has lower energy efficiency than PEMFC (Polymer Electrolyte Membrane Fuel Cell); however, it has several advantages in terms of fuel storage and use. It is pretty easy to be stored and used without any additional colling and heating devices because of its insensitive liquid methanol to temperature. In conclusion, DMFC system is the most suitable device for small mobile vehicles.

  • PDF

인산형 연료전지의 다공성전극 제조에 관한 기초적연구 (Fundamental Studies on the Manufactruring of prouse Electrode for Plosphoric Acid Fuel Cell.)

  • 김영우;박정일;이주성
    • 한국표면공학회지
    • /
    • 제22권2호
    • /
    • pp.55-61
    • /
    • 1989
  • A fuel cell which causes electrochemical ratio of conventional with oxygen consists of mainly there parts, such as electrolyte, fuel and oxidant electrode. IN this paper, most efforts were delivered to manufacturing PETE-bonded gas-diffusion electrode, and preparation methods of the porous electrodes has been discussd. A medio temperature, phosphoric acid fuel cell (PAFC) provided with fuel (hydrogen) and oxygen showed oxygen showed excellent performance characteristics with made electrodes. Performance data obtained from hydrgen-oxygen cell were presented to illustrate their properties. It was found that the optimum amounts of platinum in clectrode for hydrgen-oxygen PAFC were about 3mg/cm3 and the PTFE content of gas diffusion layer and catalyst layer were 25% and 15%, respectively.

  • PDF

PEM 연료전지 시스템 모델링-자동차용 연료전지 시스템의 주요 작동 변수 변경에 따른 시스템 효율 민감도 분석 (Modeling of PEM Fuel Cell System-Sensitivity Analysis of System Efficiency with Different Main Operating Parameters of Automotive Fuel Cell System)

  • 김한상;강병길;원권상
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.401-410
    • /
    • 2019
  • The operating conditions greatly impact the efficiency and performance of polymer electrolyte membrane (PEM) fuel cell systems and must be properly managed to ensure better performance and efficiency. In particular, small variations in operating conditions interact with each other and affect the performance and efficiency of PEM fuel cell systems. Thus, a systematic study is needed to understand how small changes in operating conditions affect the system performance and efficiency. In this paper, an automotive fuel cell system (including cell stack and balance of plant [BOP]) with a turbo-blower was modeled using MATLAB/Simulink platform and the sensitivity analyses of main operating parameters were performed using the developed system model. Effects of small variations in four main parameters (stack temperature, cathode air stoichiometry, cathode pressure, and cathode relative humidity) on the system efficiency were investigated. The results show that cathode pressure has the greatest potential impact on the sensitivity of fuel cell system efficiency. It is expected that this study can be used as a basic guidance to understand the importance of achieving accurate control of the fuel cell operating conditions for the robust operation of automotive PEM fuel cell systems.

분리판의 채널 높이에 따른 1 kWe 급 고체산화물 연료전지 스택 수치 해석 (Numerical Analysis in a 1 kWe SOFC Stack for Variation of the Channel Height in Separators)

  • 윤호원;김영진;이근우;김현진;윤경식;유지행
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.550-556
    • /
    • 2022
  • In this study, the flow uniformity was analyzed by performing numerical analysis on the 1 kWe internal manifold type solid oxide fuel cell stack according to the channel height of the separator. Also, it was examined by varying the fuel utilization rate and oxygen utilization rate. From the calculation results, we found that as the channel height of the separator decreased, the pressure drop increased exponentially. In addition, it was found that as the channel height of the separator decreased, the gas flow resistance inside the unit cell increased, and the flow resistance increased the pressure drop, thereby improving the flow uniformity inside the stack. Finally, the calculation results showed that as the fuel and oxygen utilization increased, the flow uniformity also improved.

탄소연료를 이용하는 고체 산화물 연료전지의 연료극 반응 수치해석 (Numerical Modeling of Anodic Reaction of Carbon-Rich Fuel at Solid Oxide Fuel Cell)

  • 임호;김종필;송주헌;장영준;전충환
    • 에너지공학
    • /
    • 제19권3호
    • /
    • pp.188-194
    • /
    • 2010
  • DCFC는 가스 터빈이나 엔진과 달리 탄소를 사용하여 전기화학반응을 통해 직접 전기를 생산하는 연료전지이며, 주요 특징으로 기존의 발전설비 보다 높은 효율과 낮은 배기 배출물을 발생한다. 본 연구에서는 간단한 열역학 평형 해석을 통해 CO와 $CO_2$가 이론 기전력에 미치는 영향을 확인하였으며, 2차원 CFD 해석 방법을 이용하여 온도에 따른 반응 생성물 변화를 살펴보았다. 그 결과, CO 생성 반응(Boudouard 반응)을 동시에 고려한 이론 기전력 값은 $CO_2$ 생성 반응만 고려한 값(약 1.02 V)보다 크며, 특히 온도가 증가할수록 그 값이 증가함을 보여주었다. 2차원 수치해석 결과를 통하여서 Boudouard 반응이 고온으로 갈수록 중요하며, 비활성 기체로 인하여 Boudouard 반응이 지연됨을 확인하였다.

저온영역에서 단열용기를 이용한 연료전지 모의 실험 (Simulation Experiment of PEMFC Using Insulation Vessel at Low Temperature Region)

  • 조인수;권오정;김유;현덕수;박창권;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.403-409
    • /
    • 2008
  • Polymer electrolyte membrane fuel cell (PEMFC) is very interesting power source due to high power density, simple construction and operation at low temperature. But it has problems such as high cost, improvement of performance, effect of temperature and initial start at low temperature. These problems can be approached to be solved by using experiment and mathematical method which are general principles for analysis and optimization of control system for heat and hydrogen detecting management. In this paper, insulation vessel and control system for stable operation of fuel cell at low temperature were developed for experiment. The constant temperature capability and the heating time at sub-zero temperatures with insulation control system were studied by using a heating bar of 60W class. PEMFC stack which was made by 4 cells with $50\;mc^2$ active area in each cell is a thermal source. Times which take to reach constant temperature by the state of insulation vacuum were measured at variable environment temperatures. The test was performed at two conditions: heating mode and cooling mode. Constant temperature capability was better at lower environment temperature and vacuum pressure. The results of this experiment could be used as basis data about stable operation of fuel cell stack in low temperature zone.

Preparation and Characterization of Ionic Liquid-based Electrodes for High Temperature Fuel Cells Using Cyclic Voltammetry

  • Ryu, Sung-Kwan;Choi, Young-Woo;Kim, Chang-Soo;Yang, Tae-Hyun;Kim, Han-Sung;Park, Jin-Soo
    • 전기화학회지
    • /
    • 제16권1호
    • /
    • pp.30-38
    • /
    • 2013
  • In this study, a catalyst slurry was prepared with a Pt/C catalyst, Nafion ionomer solution as a binder, an ionic liquid (IL) (1-butyl-3-methylimidazolium tetrafluoroborate), deionized water and ethanol as a solvent for the application to polymer electrolyte fuel cells (PEFCs) at high-temperatures. The effect of the IL in the electrode of each design was investigated by performing a cyclic voltammetry (CV) measurement. Electrodes with different IL distributions inside and on the surface of the catalyst electrode were examined. During the CV test, the electrochemical surface area (ESA) obtained for the Pt/C electrode without ILs gradually decreased owing to three mechanisms: Pt dissolution/redeposition, carbon corrosion, and place exchange. As the IL content increased in the electrode, an ESA decrement was observed because ILs leaked from the Nafion polymer in the electrode. In addition, the CVs under conditions simulating leakage of ILs from the electrode and electrolyte were evaluated. When the ILs leaked from the electrode, minor significant changes in the CV were observed. On the other hand, when the leakage of ILs originated from the electrolyte, the CVs showed different features. It was also observed that the ESA decreased significantly. Thus, leakage of ILs from the polymer electrolyte caused a performance loss for the PEFCs by reducing the ESA. As a result, greater entrapment stability of ILs in the polymer matrix is needed to improve electrode performance.

BSCF계 혼합전도성 공기극의 두께에 따른 고체산화물 연료전지의 전기화학적 특성 (Electrochemical Performance of the Solid Oxide Fuel Cell with Different Thicknesses of BSCF-based Cathode)

  • 정재원;유충열;주종훈;유지행
    • 한국수소및신에너지학회논문집
    • /
    • 제24권2호
    • /
    • pp.186-192
    • /
    • 2013
  • In order to reduce the costs and to improve the durability of solid oxide fuel cell (SOFC), the operating temperature should be decreased while the power density is maintained as much as possible. However, lowering the operating temperature increases the cathode interfacial polarization resistances dramatically, limiting the performance of low-temperature SOFC at especially purely electronic conducting cathode. To improve cathode performance at low temperature, the number of reaction sites for the oxygen reduction should be increased by using a mixed ionic and electronic conducting (MIEC) material. In this study, anode-supported fuel cells with two different thicknesses of the MIEC cathode were fabricated and tested at various operating temperatures. The anode supported cell with $32.5{\mu}m$-thick BSCFZn-LSCF cathode layer showed much lower polarization resistance than that with $3.2{\mu}m$ thick cahtode and higher power density especially at low temperature. The effects of cathode layer thickness on the electrochemical performance are discussed with analysis of impedance spectra.