• Title/Summary/Keyword: Frequency Voltage Converter

Search Result 1,056, Processing Time 0.03 seconds

Design of High Frequency Heating Power Supply System Using Peck Current Mode Control (피크전류모드 제어를 적용한 고주파 심부발열 전원장치 설계)

  • Xu, Guo-Cheng;Zheng, Tao;Piao, Sheng-Xu;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.61-65
    • /
    • 2017
  • In this paper a prototype of high frequency heating power supply system based on the high frequency heating principle is designed to take the place of acupuncture, moxibustion, warm dressing treatment and some other traditional physical therapy methods. Which possess the advantages of low cost, convenient, easy operation and good effect. The high frequency heating power supply can generate a pulse voltage of more than 1KV with 300KHz switching frequency to heat the patient's skin. The skin temperature can reach to $41{\sim}42^{\circ}C$. The peak current control method is used to maintain the skin temperature in the designed range. The design of the main circuit is based on the flyback converter topology. An easier and practical design method is proposed in this paper. The power supply system prototype is verified to be stable and reliable by both the simulation and experimental results.

Modeling & Operating Algorithm of Islanding Microgrid with Wind Turbine, Diesel Generator and BESS (풍력-디젤-BESS 독립형 마이크로그리드 모델링 및 운전제어 알고리즘에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5893-5898
    • /
    • 2014
  • This paper proposes a modeling method and operating algorithm of an islanding microgrid that is composed of a Battery Energy Storage System (BESS), wind turbine and diesel generator applied in island areas. Initially, the bilateral AC/DC converter was designed for charge/discharge for frequency and voltage to be maintained within the proper ranges according to the load and weather change, and the operating method was proposed for a diesel generator to operate when power supply from the wind turbine or BESS is insufficient. The proposed modeling and controller design method of BESS was applied to a typical islanded microgrid with a wind turbine and diesel generator. The frequency and voltage was kept within the permissible ranges and the proposed method was proven to be appropriate through simulations.

Manufacture and Characteristics of the Planar Transformer using low power loss magnetic materials (저손실 자심재료를 이용한 평면변압기 제조 및 동작특성)

  • Lee, Hae-Yon;Heo, Jeong-Seob;Kim, Hyun-Sik;Park, Hye-Young;Ustinov, Evgeniy
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.19-22
    • /
    • 2004
  • The resonant planar transformer, which had power capacity of 300 W, input voltage of 220 V, output voltage of 15 V, and switching frequency of 500 kHz, was designed and manufactured by using the planar core with large effective area and the flat copper lead frames for miniaturization and high efficiency of the switching mode power supply (SMPS). As well as, a resonant converter equipped with the above mentioned planar transformer was manufactured and electromagnetic characteristics were investigated. The numerical value of turns for 1st and 2nd winding were 12 and 2 respectively. The self inductance of 1st winding was 33.2 ${\mu}H$, very low leakage inductance of 1.27 ${\mu}H$, and the coupling factor of 0.98 were obtained at switching frequency of 300 kHz. The high efficiency of 88.21 % for the SMPS equipped with planar transformer was obtained at power capacity of 300 W.

  • PDF

Development of an Algorithm for Detecting High Impedance Fault in Low Voltage DC Distribution System using Accumulated Energy of Fault Current (고장전류의 누적 에너지를 이용한 저압직류 배전계통의 고저항 지락고장 검출 알고리즘 개발)

  • Oh, Yun-Sik;Noh, Chul-Ho;Kim, Doo-Ung;Gwon, Gi-Hyeon;Han, Joon;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.71-79
    • /
    • 2015
  • Recently, new Low Voltage DC (LVDC) power distribution systems have been constantly researched as uses of DC in end-user equipment are increased. As in conventional AC distribution system, High Impedance Fault (HIF) which may cause a failure of protective relay can occur in LVDC distribution system as well. It, however, is hard to be detected since change in magnitude of current due to the fault is too small to detect the fault by the protective relay using overcurrent element. In order to solve the problem, this paper presents an algorithm for detecting HIF using accumulated energy in LVDC distribution system. Wavelet Singular Value Decomposition (WSVD) is used to extract abnormal high frequency components from fault current and accumulated energy of high frequency components is considered as the element to detect the fault. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed algorithm using ElectroMagnetic Transient Program (EMTP) software. Simulation results considering various conditions show that the proposed algorithm can be utilized to effectively detect HIF.

Electrical Properties of Thickness-Vibration-Mode Multilayer Piezoelectric Transformer using Low Temperature Sintering (Pb,Ca,Sr,)(Ti,Mn,Sb)O3 Ceramics (저온소결 (Pb,Ca,Sr,)(Ti,Mn,Sb)O3 세라믹스를 이용한 두께진동모드 적층 압전 변압기의 전기적 특성)

  • Yoo, Ju-Hyun;Yoo, Kyung-Jin;Kim, Do-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.948-952
    • /
    • 2007
  • In this study, a low temperature sintering multilayer piezoelectric transformer for a DC-DC converter was manufactured using $(Pb,Ca,Sr,)(Ti,Mn,Sb)O_3$ ceramics. Its electrical properties were investigated according to the variation in frequency and load resistance. The voltage step-up ratio of the multilayer piezoelectric transformer showed a maximum value at a resonant frequency of input part and increased with an increase of load resistance. The efficiency of the multilayer piezoelectric transformer showed the highest value at a load resistance of 17 $\Omega$. The output power was increased with increasing input voltage. Temperature increase of the multilayer piezoelectric transformer was increased with the increase of output power. At the load resistance of 17 $\Omega$, the multilayer piezoelectric transformer showed the temperature rises of about $20^{\circ}C$ at the output power of 18 W, and stable driving characteristics.

Capacitor Failure Detection Technique for Microgrid Power Converter (마이크로그리드 전력변환장치용 커패시터 고장 검출 기법)

  • Woo-Hyun Lee;Gyang-Cheol Song;Jun-Jae An;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

The Buck DC-DC Convener with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • 김상돈;라병훈;이현우;김광태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.73-80
    • /
    • 2003
  • This Paper Proposes instantaneous following control method to control pulse modulation switching converter by using principle that reset time of integrator is inverse proportion in size of integrator input voltage. proposed control method acts of fixed frequency and control switch calculates time of become turn on and turn off using analog integrator. Duty ratio that express switching time of converter is depended on mean value of switching variable and following time consists in one cycle. Follow to do order exactly stationary state as well as transition state, and controller corrects mean value of control variable and control reference value and control as control error gets into zero. Proposed control method could experimented and know that experiment result and theory are agreeing well through this using the buck converter.

A Programmable Fast, Low Power 8 Bit A/D Converter for Fiber-Optic Pressure Sensors Monitoring Engines (광섬유 엔진 모니터용 압력센서를 위한 프로그램 가능한 고속 저전력 8 비트 아날로그/디지탈 변환기)

  • Chai, Yong-Yoong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.163-170
    • /
    • 1999
  • A programmable A/D converter for an embedded fiber-optic combustion pressure sensor has been designed with 8 N and P channel MOSFETs, respectively. A local field enhancement for reducing programming voltage during writing as well as erasing an EEPROM device is introduced. In order to observe linear programmability of the EEPROM device during programming mode, a cell is developed with a $1.2\;{\mu}m$ double poly CMOS fabrication process in MOSIS. It is observed that the high resolution, of say 10mVolt, is valid in the range 1.25volts to 2volts. The experimental result is used for simulating the programmable 8 bit A/D converter with Hspice. The A/D converter is demonstrated to consume low power, $37\;{\mu}W$ by utilizing a programming operation. In addition, the converter is attained at the conversion frequency of 333 MHz.

  • PDF

DC-DC Boost Converter with Dead-Time Adaptive Control and Power Switching (Dead-Time 적응제어 기능과 Power Switching 기능을 갖는 DC-DC 부스트 변환기)

  • Lee, Joo-young;Yang, Min-jae;Kim, Doo-Hoi;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.361-364
    • /
    • 2013
  • Since the non-overlapping gate driver used in conventional DC-DC boost converters generates fixed dead-times, the converters suffer from the body-diode conduction loss or the charge-sharing loss. A adaptive control method has been proposed to reduce these loses. In this method, however, occurrence of and overlapping time of two power transistors in CCM results in reduction of efficiency. In this paper, to overcome this problem a new adaptive control method in proposed, and a DC-DC boost converter with the proposed adaptive control and power switching has been designed in a 0.35um CMOS process. The designed converter outputs 3.3V from a input voltage of 2.5V. The switching frequency is 500kHz and the maximum power efficiency is 95.3% at a load current 150mA. The designed chip area is $1720um{\times}1280um$.

  • PDF

Design of The 10bit 80MHz CMOS D/A Converter with Switching Noise Reduction Method (스위칭 잡음 감소기법을 이용한 10비트 80MHz CMOS D/A 변환기 설계)

  • Hwang, Jung-Jin;Seon, Jong-Kug;Park, Li-Min;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.35-42
    • /
    • 2010
  • This paper describes a 10 bit 80MHz CMOS D/A converter for wireless communication system. The proposed circuit in the paper is implemented with a $0.18{\mu}m$ CMOS n-well 1-poly 6-metal process. The architecture of the circuit consists of the 4bit LSB with binary decoder, and both the 3bit ULSB and the 3bit MSB with the thermometer decoder. The measurement results demonstrates SFDR of 60.42dBc at sampling frequency 80MHz, input frequency 1MHz and ENOB of 8.75bit. INL and DNL have been measured to be ${\pm}$0.38LSB and ${\pm}$0.32LSB and glitch energy is measured to be 4.6$pV{\cdot}s$. Total power dissipation is 48mW at 80MHz(maximum sampling frequency) with a single power supply of 1.8V.