• 제목/요약/키워드: Frequency Generator

검색결과 1,195건 처리시간 0.027초

풍력발전용 권선형 유도발전기의 회전자 여자주파수를 이용한 속도와 출력제어 (A Speed and Power Control of DFIG Using the Exciting Frequency for Wind Power Generating)

  • 이우석;오철수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.349-356
    • /
    • 1999
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed and power control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. For the speed control analysis, torque simulation is performed whereby the different slip between operating motor driving frequency and synchronous frequency of M-G system applied. To keep the output rating of the generator, the exciting frequency and voltage attenuation are applied.

  • PDF

유압 구동식 발전장치의 정주파수 제어 - 시뮬레이션 - (Constant Frequency Control of Generating System Driven by Hydraulic Power - Simulation -)

  • 정용길;오인호
    • 수산해양기술연구
    • /
    • 제26권3호
    • /
    • pp.275-281
    • /
    • 1990
  • This study suggests a new type shaft generator driven by hydraulic power suitable for small size vessels. Since the shaft generator system is very easy to be affected by disturbances such as speed variation of the main engine and the load variation of the generator, a robust servo control must be performed to obtain stable electric power with constant frequency. So, in this study the robust servo control method is adopted to the controller design. Dynamic characteristics on the frequency variations of the electric power output according to the disturbances are investigated by computer simulations. From the considerations of the computer simulation results, it is ascertained that the shaft generator system proposed in this study had good control performances.

  • PDF

SS-OCT용 정현파 및 트리거 펄스 발생기 (Sine-wave and Trigger Pulse Generator for SS-OCT)

  • 엄진섭
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

저주파수용 ZnO 압전 마이크로 전원의 설계와 분석 (Design and analysis of ZnO piezoelectric micro power generators with low frequency)

  • 정귀상;윤규형
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.372-376
    • /
    • 2009
  • This paper describes the characteristics of piezoelectric micro power generators by the ANSYS FEA(finite element analysis). The micro power generator was designed to convert ambient vibration energy to electrical power as a ZnO piezoelectric material. To find optimal model in low vibration ambient, the shape of power generator was changed with different membrane width, thickness, length, and proof mass size. Using the ANSYS modal analysis, bending mode and stress distribution of optimal model were analyzed. Moreover, the displacement with the frequency range was analyzed by harmonic analysis. From the simulation results, the resonance frequency of optimal model is about 373 Hz and investigate the possibility of ZnO micro power generator for ambient vibration applications.

독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석 (Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid)

  • 허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

A Wide Frequency Range LLC Resonant Controller IC with a Phase-Domain Resonance Deviation Prevention Circuit for LED Backlight Units

  • Park, YoungJun;Kim, Hongjin;Chun, Joo-Young;Lee, JooYoung;Pu, YoungGun;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.861-875
    • /
    • 2015
  • This paper presents a wide frequency range LLC resonant controller IC for LED backlight units. In this paper a new phase-domain resonance deviation prevention circuit (RDPC), which covers a wide frequency and input voltage range, is proposed. In addition, a wide range gate clock generator and an automatic dead time generator are proposed. The chip is fabricated using 0.35 μm BCD technology. The die size is 2 x 2 mm2. The frequency of the clock generator ranges from 38 kHz to 400 kHz, and the dead time ranges from 300 ns to 2 μs. The current consumption of the LLC resonant controller IC is 4 mA for a 100 kHz operation frequency using a supply voltage of 15 V.

VCO 표류 성분 상쇄기와 빗쌀 하모닉 발생기를 이용한 주파수 대역 확장기의 구현 (Implementation of Frequency Bandwidth Expander using VCO Drift Canceller and Comb generator)

  • 강승민
    • 한국통신학회논문지
    • /
    • 제24권9B호
    • /
    • pp.1683-1689
    • /
    • 1999
  • VCO의 표류성분 제거기와 빗쌀 하모닉 발생기를 이용하여 주파수를 상향 변환하면서 동시에 주파수 대역폭을 확장하는 시스템을 구현하였다. 출력 주파수 범위가 220∼280MHz, 분해능이 5MHz인 저주파수 합성기의 출력을 1660∼2140MHz의 광대역 주파수로 확장한다. 최종출력의 위상 잡음 상태는 저주파수 합성기와 빗쌀 하모닉 발생기에 의해 결정되며 VCO의 표류성분은 최종 출력에 나타나지 않는다. 필터 뱅커처럼 VCO의 조절로 주파수가 60MHz의 단위로 가변되는데 이때의 가변시간은 3usec이하이며, 스퓨리어스는 -55dBc이하이다. VCO의 출력 주파수 범위를 확장하면 쉽게 출력 대역폭을 추가로 확장할 수 있으며, 빠른 스위칭 시간을 요구하는 광대역 초고주파 합성기에 응용될 수 있다.

  • PDF

함정용 추적레이더 성능 검증을 위한 모의표적신호발생장치 개발 (Development of Virtual Target Signal Generator for Verifying the Shipborne Tracking Radar Performance)

  • 이희민;손재현;나영진;김동환
    • 한국군사과학기술학회지
    • /
    • 제15권1호
    • /
    • pp.66-74
    • /
    • 2012
  • The virtual target signal generator was developed to verify the shipborne tracking radar performance. It was used to DRFM(Digital RF Memory) method to generate the virtual moving targets. The target signal includes Doppler shift and RCS according to the target motion. And the signal generator can make jamming signal and clutter to test shipborne radar performance at real environmental condition. This paper described the functional diagram and the hardware configuration items to meet the test requirements for the tracking radar. And it showed the critical design points for the sub-systems. The signal generator which was developed in this paper shared the operational information of the radar with the radar command and control part. To test the frequency agility of the radar, it had the local oscillator which could do high speed frequency switching according to radar information. By communicating between the signal generator and the radar command and control part, the local oscillator of signal generator could be controlled every pulse. It reduced the instantaneous bandwidth of signal generator and minimized the spurious. So it lowered the probability of generating wrong targets.

전원탈락에 따른 계통주파수저하문제검토 제1보 (Study on the Characteristic of System Frequency Decay In Case of Large Generator Unit Outage)

  • 송길영
    • 전기의세계
    • /
    • 제18권3호
    • /
    • pp.7-14
    • /
    • 1969
  • According to the construction of Seoul Thermal #5 (250MW) unit, there will be prospected several new problems on the power system operation. This paper describes the characteristic of system frequency decay during severe emergencies which result in sudden outage of such large generator unit. It also studies the factors involved in applying under frequency relays to maintan an allowable frequency level and to prevent total area collapse by automatic load shedding program.

  • PDF

풍력발전기 출력변동성에 대비한 가변속 양수발전기의 주파수 제어효과 (Effect of Adjustable Speed Pumped Storage Power Generator on the Frequency Control Against the Intermittence of Wind Turbine Output)

  • 박민수;전영환
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.338-342
    • /
    • 2014
  • Energy storage is a key issue when integrating large amounts of intermittent and non-dispatchable renewable energy sources into electric power systems. To maintain the instantaneous power balance and to compensate for the influence of power fluctuations from renewable sources, flexible capability for power control is needed. Adjustable Speed Pumped Storage Power Generator is pumped storage unit that is adjustable for pump output adjustments as well as the highest efficiency operations because it has fast response time. In this paper we address the adjustable speed pumped storage power generator for frequency control against the intermittence of wind turbine output and calculate the appropriate capacity of adjustable speed pumped storage power generator.