• 제목/요약/키워드: Fracture shape

검색결과 595건 처리시간 0.027초

충격파관을 이용한 세라믹 돔의 파괴 특성에 관한 연구 (A Study on Fracture Characteristic of Ceramic Dome Using Shock Tube)

  • 황권태;김재훈;이영신;박종호;권순국;송기혁;윤수진;이기천
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1274-1278
    • /
    • 2009
  • Fracture characteristics for plate and dome shapes of glass filled ceramics using shock tube were carried out. Glass filled ceramics have been considered as a promising candidate material for the dome port cover of air breathing engine. This part of the air breathing engine has an important role as separated membrane between combustion and external air, and needs the frangible characteristics that the particles of fractured glass filled ceramics should not affect the internal components of combustion. The objectives of this study are to evaluate the fracture pressures for various thicknesses and diameters of shock impact area. Also fracture phenomena of separated membrane using a shock tube compare with analytical method. The experimental apparatus consists of a driver, a driven section and a dump tank. The used material is glass filled ceramic made from Corning company. Specimens have the thickness of 3, 4.5 and 6mm. It is expected that the results obtained from this study can be used in the basic data for the dome port cover design of an air breathing engine.

Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

  • Choi, Kang-Young;Yang, Jung-Dug;Chung, Ho-Yun;Cho, Byung-Chae
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.291-300
    • /
    • 2012
  • The incidence of condylar fractures is high,but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture.

12Cr강의 피로특성에 미치는 Ni+Mo 첨가의 영향 (Effect of Ni and Mo Addition on Fatique Property in 12Cr Steel)

  • 이진경;배동수
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.435-441
    • /
    • 2021
  • This research was performed to study the effect of the Ni + Mo addition on the fatigue properties in 12Cr steel. After heat treatment of 12Cr steel and 12Cr-Ni-Mo steel, tensile tests, impact tests, hardness tests, and rotary bending fatigue tests were performed, respectively. The fatigue fracture surface was observed and analyzed using SEM and EDS. The fatigue limit of 12Cr steel was 554 MPa, which was 49 MPa higher than 505 MPa of 12Cr-Ni-Mo steel. Striations, which are the shape of the typical fatigue fracture surface, were observed at the fracture surface near the starting point of fatigue fracture in the 12Cr steel and 12Cr-Ni-Mo steel. However, unlike the case of 12Cr steel, 12Cr-Ni-Mo steel also had a mixed fracture surface with the fatigue and the ductile fracture surface. When brittle non-metallic inclusions exist near the starting point of fatigue failure, the crack propagation was further promoted and the fatigue life was drastically reduced.

내부 불연속 요소를 사용한 콘크리트의 파괴진행해석 (Analysis of Progressive Fracture in Concrete using Finite Elements with Embedded Discontinuous Line)

  • 송하원;우승민;김형운
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.450-455
    • /
    • 1998
  • In this paper, finite element with embedded discontinuous line is introduced in order to avoid the difficulties of adding new nodal points along with crack growth in discrete crack model. With the discontinuous element using discontinuous shape function, stiffness matrix of finite element is derived and dual mapping technique for numerical integration is employed. Using the finite element program made with employed algorithms, algorithm is verified and fracture analysis of simple concrete beam is performed.

  • PDF

충격하중을 받는 취성재료의 동적응력확대계수 결정 (Detemination of Dynamic Stress Intensity Factor of Brittle Materials under Impact Loading)

  • 이억섭;이찬석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.381-386
    • /
    • 1993
  • This paper describes the dynamic fracture behavior of brittle materials under impact loading by using INSAMCR program with instrumented charpy test machine. To calculate the Dynamic Stress Intensity Factor The finite element analysis methods program, INSAMCR, was used. Dynamic fracture characteristic was researched to verify a relationship between Dynamic Stress Intensity Factor and crack tip propagation velocity in WC-6%Co. The relationship between Dynamic Stress Intensity Factor and crack tip velocity revealed typical .GAMMA. shape. INSAMCR was run to verify experimental results in WC-6%Co and shows a good coincidence.

  • PDF

열간단조 금형강의 열충격특성연구 (Analysis of Thermal Shock in Tool Steels for Hot Forging)

  • 김정운;김봉준;조이석;문영훈
    • 열처리공학회지
    • /
    • 제14권3호
    • /
    • pp.155-159
    • /
    • 2001
  • The thermal shock resistance has been investigated and compared in three hot-work tool steels. The resistance to thermal shock is first of all a matter of good toughness and ductility. Therefore, a proper hot-work tool steel should be characterized by high fracture strength and high temperature toughness. In this study, new test method is proposed to measure the thermal shock resistance. New method is basically based on Uddeholm' thermal shock test but some modification has been properly applied. Based on these results, some critical temperature($T_{fractures}$) at which fracture occur can be measured to characterize the thermal resistance of the materials. The specific values of ${\Delta}T$, the temperature difference between holding temperature and $T_{fractures}$, has been successfully used as a measure of the thermal shock resistance in this study, the results showed that the thermal shock method used in this study was properly modified.

  • PDF

한계하중법을 이용한 Curved CT 시험편의 파괴저항곡선에 미치는 형상변수 영향 평가 (Evaluation of Shape Parameter Effect on the J-R Curve of Curved CT Specimen Using Limit Load Method)

  • 신인환;박치용;석창성;구재민
    • 대한기계학회논문집A
    • /
    • 제38권7호
    • /
    • pp.757-764
    • /
    • 2014
  • 본 연구에서는 한계하중법을 이용하여 Curved CT 시험편의 J-적분에 미치는 형상변수 영향을 평가하였다. 주요 형상변수인 시험편의 길이와 폭의 비(L/W), 평균곡률반경과 두께의 비($R_m/t$)에 대한 파괴인성시험 후, ASTM 시험법에서 제시한 표준시험편의 J-적분과 한계하중법으로 구한 J-적분을 각각 적용하여 구한 파괴저항곡선을 평가하였다. 또한 배관의 파괴저항곡선을 잘 모사한다고 알려진 휨 광폭평판(CWP) 및 표준시험편의 파괴저항곡선과 비교 고찰하여 최종적으로 Curved CT 시험편의 파괴저항곡선에 대한 유효성을 평가하였다. 본 논문의 결과는 향후 실배관의 정확한 파괴인성을 평가하는 데 있어 Curved CT 시험편의 적용가능성을 평가하는 데에 활용할 수 있다.

1000MPa급 DP강 MIG 아크 브레이징 접합부의 기계적 성질에 미치는 브레이징 전류의 영향 (Effects of Brazing Current on Mechanical Properties of Gas Metal Arc Brazed Joint of 1000MPa Grade DP Steels)

  • 조욱제;윤태진;곽승윤;이재형;강정윤
    • Journal of Welding and Joining
    • /
    • 제35권2호
    • /
    • pp.23-29
    • /
    • 2017
  • Mechanical properties and hardness distributions in arc brazed joints of Dual phase steel using Cu-Al insert metal were investigated. The maximum tensile shear load was 10.4kN at the highest brazing current. It was about 54% compared to tensile load of base metal. This joint efficiency is higher than that of joint of DP steel using Cu-based filler metals which are Cu-Si, Cu-Sn. Fracture positions can be divided into two types. Crack initiation commonly occurred at three point junction among upper sheet, lower sheet and the fusion zone. However crack propagations were different with increasing the brazing current. In case of the lower current, it instantaneously propagated along with the interface between fusion zone and upper base material. On the other hand, in case of higher current, a crack propagation occurred through fusion zone. When the brazing current is low (60, 70A), the interface shape is flat type. However the interface shape is rough type, when the brazing current is high (80A). It is thought that the interface shapes were the reason why the crack propagations were different with brazing current. The interface was the intermetallic compounds which consisted of $(Fe,Al)_{0.85}Cu_{0.15}$ IMC formed by crystallization at $1200^{\circ}C$during cooling. Therefore the maximum tensile shear load and the fracture behavior were determined by a interface shape and effective sheet thickness of the fracture position.

악간고정 없는 하악골 골절의 관혈적 정복술: 후향적 연구 (Open reduction of mandibular fracture without maxillomandibular fixation: retrospective study)

  • 이충현;김철환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권4호
    • /
    • pp.255-263
    • /
    • 2011
  • Introduction: Maxillomandibular fixation (MMF) is essential before surgery under general anesthesia in maxillofacial trauma patients. MMF is used basically to reconstruct the occlusion and occlusal stability to recover the facial shape and oral functions. The arch bar and wire is a traditional method for MMF, but it can not only bring pressure to the periodontal ligaments and teeth but also cause a penetrating injury to the surgeons. Materials and Methods: In this study, 198 patients with an open reduction using a manual reduction without MMF from September 2005 to May 2010 in Dankook University Dental Hospital were subjected to a follow-up evaluation during the postoperative 4 months periods. This study evaluated the incidence of complications according to the condition of the patient (gender, age), the state of bony union of the fracture sites and a numeric rating scale evaluation for postoperative pain scoring. Results: 1. The complications were classified into major and minor according to the seriousness, and the major complication rate was as low as 2.02%. Only 2 cases of re-operations (1.01%) were encountered. In the classification according to the fracture line, plate fracture was observed in both cases of mandibular symphysis fracture, and angle fractures and loosening of two screws were noted in the case of mandibular angle fracture. 2. The complication rate was similar regardless of gender and age. 3. The degree of bony union was satisfactory, and the complication rate was reduced as the bony union improved. 4. More patients complained of pain as the operation time was increased. Conclusion: The use of MMF is not always necessary if a skilled assistant is provided to help manually reduce the fracture site. Compared to other studies of mandibular fracture surgery using MMF, the complication rate was similar using only manual reduction and the patients' discomfort was reduced without MMF.