• Title/Summary/Keyword: Format Detection

Search Result 169, Processing Time 0.029 seconds

Improvement of Encoding Detection Algorithm for Multi-byte Encoded Data with Errors (오류가 발생한 멀티바이트 인코딩 데이터의 인코딩 기법 판별 알고리즘 개선)

  • Bae, Junwoo;Kim, Seonbeom;Park, Heejin
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.13 no.2
    • /
    • pp.18-25
    • /
    • 2017
  • In computer science, an encoding is a standardization of converting information to one format for audio, video or text. Therefore, the encoding information of the data should be known to open and read it and there are algorithms detecting encoder of the data. However, some informations of data could be disappeared by packet loss when transmitted on network, especially, if the data is snatched by packet sniffing or eavesdropping from wireless communications. In this paper, we improve the performance of encoding detection algorithm of 'uchardet' program for multi-byte encoded data with errors based on bit-shift algorithm. To simulate the performance, we generated Korean and Japanese text data with errors that is removed some random bits at random positions. Then the detection algorithm are tested using the data and 'uchardet-bitshift' showed better performance than 'uchardet'. When Korean texts are used, 'uchardet' could detect perfectly with ≤0.005% errors but it showed 0% detection rate with ≥1% errors while 'uchardet-bitshift' detected perfectly with ≤0.05% errors and it showed correct detection cases with ≥1% errors. Japanese texts with errors tend to report falsely as Chinese encoding because Japanese texts include lots of Chinese characters. As a results, we improved encoding detection algorithms by applying bit shift operation.

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

Development of Automatic Crack Detection using the Gabor Filter for Concrete Structures of Railway Tracks (가버 필터를 사용한 철도 콘크리트 궤도 도상의 자동 균열 감지 개발)

  • Na, Yong-Hyoun;Park, Mi-Yun;Park, Ji-Soo;Park, Sung-Baek;Kwon, Se-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.458-465
    • /
    • 2018
  • Purpose: Concrete track that affects on railway safety can detect cracks using image processing technique. However, since a condition of concrete track and surface noisy are obstructed to detect cracks, there is a need for a way to remove them effectively. Method: In this study, we proposed an image processing to detect cracks effectively for Korean railway and verified its performance through experiment. We developed image acquisition system for capture a railway concrete track and acquired railway concrete track images, randomly selected 2000 images and detected cracks in the image process using proposed Gabor Filter Bank methods. Results: As a result, 94% of detection rate are matched to the actual cracks in same quality and format railway concrete track image. Conclution: The crack detection method using Garbor Filter Bank was confirmed to be effective for crack image including noise in the Korean railway concrete track. This system is expected to become an automated maintenance system in the existing human-centered railway industry.

A study on improving self-inference performance through iterative retraining of false positives of deep-learning object detection in tunnels (터널 내 딥러닝 객체인식 오탐지 데이터의 반복 재학습을 통한 자가 추론 성능 향상 방법에 관한 연구)

  • Kyu Beom Lee;Hyu-Soung Shin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.2
    • /
    • pp.129-152
    • /
    • 2024
  • In the application of deep learning object detection via CCTV in tunnels, a large number of false positive detections occur due to the poor environmental conditions of tunnels, such as low illumination and severe perspective effect. This problem directly impacts the reliability of the tunnel CCTV-based accident detection system reliant on object detection performance. Hence, it is necessary to reduce the number of false positive detections while also enhancing the number of true positive detections. Based on a deep learning object detection model, this paper proposes a false positive data training method that not only reduces false positives but also improves true positive detection performance through retraining of false positive data. This paper's false positive data training method is based on the following steps: initial training of a training dataset - inference of a validation dataset - correction of false positive data and dataset composition - addition to the training dataset and retraining. In this paper, experiments were conducted to verify the performance of this method. First, the optimal hyperparameters of the deep learning object detection model to be applied in this experiment were determined through previous experiments. Then, in this experiment, training image format was determined, and experiments were conducted sequentially to check the long-term performance improvement through retraining of repeated false detection datasets. As a result, in the first experiment, it was found that the inclusion of the background in the inferred image was more advantageous for object detection performance than the removal of the background excluding the object. In the second experiment, it was found that retraining by accumulating false positives from each level of retraining was more advantageous than retraining independently for each level of retraining in terms of continuous improvement of object detection performance. After retraining the false positive data with the method determined in the two experiments, the car object class showed excellent inference performance with an AP value of 0.95 or higher after the first retraining, and by the fifth retraining, the inference performance was improved by about 1.06 times compared to the initial inference. And the person object class continued to improve its inference performance as retraining progressed, and by the 18th retraining, it showed that it could self-improve its inference performance by more than 2.3 times compared to the initial inference.

An Electrochemical Enzyme Immunochip Based on Capacitance Measurement for the Detection of IgG

  • Yi, Seung-Jae;Choi, Ji-Hye;Kim, Hwa-Jung;Chang, Seung-Cheol;Park, Deog-Su;Kim, Kyung-Chun;Chang, Chulhun L.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1298-1302
    • /
    • 2011
  • This study describes the development of an electrochemical array immunochip for the detection of IgG. Interdigitated immunochip platforms were fabricated by sputtering gold on a glass wafer by using MEMS process and then were coated with Eudragit S100, an enteric polymer, forming an insulating layer over the working area of immunochips. The breakdown of the polymer layer was exemplified by the catalytic action of urease which, in the presence of urea, caused an alkaline pH change. This subsequently caused an increase of the double layer capacitance of the underlying electrode. Used in conjunction with a competitive immunoassay format, this allowed the ratio of initial to final electrode capacitance to be directly linked with the concentration of analyte, i.e. IgG. Responses to IgG could be detected at IgG concentration as low as $250\;ngmL^{-1}$ and showed good linearity up to IgG concentration as high as $20\;{\mu}gmL^{-1}$.

A Method based on Ontology for detecting errors in the Software Design (온톨로지 기반의 소프트웨어 설계에러검출방법)

  • Seo, Jin-Won;Kim, Young-Tae;Kong, Heon-Tag;Lim, Jae-Hyun;Kim, Chi-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2676-2683
    • /
    • 2009
  • The objective of this thesis is to improve the quality of a software product based on the enhancement of a software design quality using a better error detecting method. Also, this thesis is based on a software design method called as MOA(Methodology for Object to Agents) which uses an ontology based ODES(A Method based on Ontology for Detecting Errors in the Software Design) model as a common information model. At this thesis, a new format of error detecting method was defined. The method is implemented during a transformation process from UML model to ODES model using a ODES model, a Inter-View Inconsistency Detection technique and a combination of ontologic property of consistency framework and related rules. Transformation process to ODES model includes lexicon analysis and meaning analysis of a software design using of multiple mapping table at algorithm for the generation of ODES model instance.

An Integrated Intrusion Detection System for a Large-scale Network Environment (대규모 네트워크 환경을 위한 통합 침입탐지 시스템)

  • 안정모;조진성;정병수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7C
    • /
    • pp.985-996
    • /
    • 2004
  • In order to solve the increasing security problems, IDSs(Intrusion Detection System) have appeared. However, local IDSs have a limit to detect various intrusions in a large-scale network environment. So there are a lot of researches in progress which organize the elements of IDS in a distributed or hierarchical manner. In this paper, we design a integrated IDS which exchanges messages between them through the standardized message format (IDMEF) and communication protocol (IDXP). We also propose a policy profile for an effective control of IDSs, and employ the PKI mechanism for mutual authentication. We implement a prototype system for the proposed IDSs communicating with Snort and analyze its performance.

An Extension of Data Flow Analysis for Detecting Polymorphic Script Virus (다형성 스크립트 바이러스 탐지를 위한 자료 흐름 분석기법의 확장)

  • Kim, Chol-Min;Lee, Hyoung-Jun;Lee, Seong-Uck;Hong, Man-Pyo
    • The KIPS Transactions:PartC
    • /
    • v.10C no.7
    • /
    • pp.843-850
    • /
    • 2003
  • Script viruses are easy to make a variation because they can be built easily and be spread in text format. Thus signature-based method has a limitation in detecting script viruses. In a consequence, many researches suggest simple heuristic methods, but high false-positive error is always being an obstacle. In order to overcome this problem, our previous study concentrated on analyzing data flow of codes and has low-false positive error, but still could not detect a polymorphic virus because polymorphic virus loads self body and changes it before make a descendent. We suggest a heuristic detection method which expands the detection range of previous method to include polymorphic script viruses. Expanded data flow analysis heuristic has an expanded grammar to detect Polymorphic copy Propagation. Finally, we will show the experimental result for the effectiveness of suggested method.

H-Band(220~325 GHz) Transmitter and Receiver for an 1.485 Gbit/s Video Signal Transmission (H-대역(220~325 GHz) 주파수를 이용한 1.485 Gbps 비디오 신호 전송 송수신기)

  • Chung, Tae-Jin;Lee, Won-Hui
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.345-353
    • /
    • 2011
  • An 1.485 Gbit/s video signal transmission system using the carrier frequency of H-band(220~325 GHz) was implemented and demonstrated for the first in domestic. The RF front-end was composed of Schottky barrier diode sub-harmonic mixers(SHM) and frequency triplers, and diagonal horn antennas for transmitter and receiver, respectively. The transmitted carrier frequency of 246 GHz was implemented in the H-band, and LO frequencies of H-band SHM is 120 GHz and 126 GHz for transmit and receive chains, respectively. The modulation scheme is ASK(Amplitude Shift Keying) where IF frequency is 5.94 GHz and the envelop detection was used in heterodyne receiver architecture, and direct detection receiver using ZBD(Zero Bias Detector) was implemented as well. The 1.485 Gbit/s video signal with HD-SDI format was successfully transmitted over wireless link distance of 5 m and displayed on HDTV at the transmitted average output power of 20 ${\mu}W$.

A Comparison of Bioacoustic Recording and Field Survey as Bird Survey Methods - In Dongbaek-dongsan and 1100-altitude Wetland of Jeju Island - (조류 조사 방법으로써 생물음향 녹음과 현장 조사의 비교 - 제주 동백동산과 1100고지 습지를 대상으로 -)

  • Se-Jun Choi;Kyong-Seok Ki
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.5
    • /
    • pp.327-336
    • /
    • 2023
  • This study aimed to propose an effective method for surveying wild birds by comparing the results of bioacoustic detection with those obtained through a field survey. The study sites were located at Dongbaek-dongsan and a 1100-altitude wetland in Jeju-do, South Korea. The bioacoustic detection was conducted over the course of 12 months in 2020. For the bioacoustic detection, a Song-meter SM4 device was installed at each study site, recording bird songs in 1-min per hour, .wav, and 44,100 Hz format. The findings of the field survey were taken from the 「Long-term trends of Bird Community at Dongbaekdongsan and 1100-Highland Wetland of Jeju Island, South Korea.」 by Banjade et al. (2019). The results of this study are as follows. First, the avifauna identified using bioacoustic detection comprised 29 families and 46 species in Dongbaek-dongsan, and 16 families and 25 species in the 1100-altitude wetland. Second, based on the song frequency, the dominant species in Dongbaek-dongsan were Hypsipetes amaurotis (Brown-eared Bulbul, 33.62%), Horornis diphone (Japanese Bush Warbler, 12.13%), and Zosterops japonicus (Warbling White-eye, 9.77%). In the 1100-altitude wetland the dominant species were Corvus macrorhynchos (Large-billed Crow, 27.34%), H. diphone (19.43%), and H. amaurotis (16.56%). Third, in the field survey conducted at Dongbaek-dongsan, the number of detected bird species was 39 in 2009, 51 in 2012, 35 in 2015, and 45 in 2018, while the bioacoustic detection identified 46 species. In the field survey conducted in the 1100-altitude wetland, the number of detected bird species was 37 in 2009, 42 in 2012, 34 in 2015, and 38 in 2018, while the bioacoustics detection identified 25 species. Overall, 43.6% of the 78 species detected in the field survey in Dongbaek-dongsan (34 species) were identified using bioacoustic detection, and 38.3% of the 47 species detected in the field survey in the 1100-altitude wetland (18 species) were identified using bioacoustic detection. Fourth, the bioacoustic detection identified 9 families and 12 species of birds in Dongbaek-dongsan, and 3 families and 7 species of birds in the 1100-altitude wetland. No results from field survey were available for these species. The identified birds were predominantly nocturnal, including Otus sunia (Oriental Scops Owl) and Ninox japonica (Northern Boobook), passage migrants, including Larvivora cyane (Siberian Blue Robin), L. sibilans (Rufous-tailed Robin), and winter visitors with a relatively small number of visiting individuals, such as Bombycilla garrulus (Bohemian Waxwing) and Loxia curvirostra (Red Crossbill). Fifth, the birds detected in the field survey but not through bioacoustic detection included 18 families and 48 species in Dongbaek-dongsan and 14 families and 27 species in the 1100-altitude wetland; the most representative families were Ardeidae, Accipitridae, and Muscicapidae. This study is significant as it provides essential data supporting the possibility of an effective survey combining bioacoustic detection with field studies, given the increasing use of bioacoustic devices in ornithological studies in South Korea.