• 제목/요약/키워드: Fluorescence.

검색결과 4,373건 처리시간 0.033초

Fluorescence Enhancement of Ethidium Bromide by DNA Bases and Nucleosides

  • Pyun, Chong-Hong;Park, Su-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권2호
    • /
    • pp.142-147
    • /
    • 1989
  • Fluorescence enhancements of ethidium bromide (EB) by solution species of low molecular weights such as DNA base molecules and nucleosides in water are reported. The degree of enhancements was determined by intensity as well as lifetime measurements for EB fluorescence. Experiments including solvent effects on absorbance and fluorescence spectra of EB, effects of protonation on the EB absorbance spectrum, and determination of equilibrium constants for EB-DNA bases have been performed to help explain the fluorescence enhancement. The results suggest that the excited state stabilization in the hydrophobic environment, the loss of torsional/vibrational energy of amino groups, and the change in the electronic transition characteristics are all responsible for the fluorescence enhancement.

Fluorescence Properties and Photoisomerization Behavior of 1-(9-Anthryl)-2-(2-quinolinyl)ethene

  • 신은주
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권11호
    • /
    • pp.1263-1268
    • /
    • 1999
  • The fluorescence properties and photoisomerization behavior of 1-(9-anthryl)-2-(2-quinolinyl)ethene (2-AQE) have been investigated in various solvents. Instead of phenyl ring in 1-(9-anthryl)-2-phenylethene, the intro-duction of quinoline ring reduces not only the fluorescence yield but also the photoisomerization yield, due to competition of efficient radiationless deactivation and an increase in the torsional barrier for twisting in the singlet manifold. The S1 decay parameters were found to be solvent-dependent due to the charge-transfer character of lowest S1 state. Polar solvents reduce the activation barrier to twisting, thus slight enhancing the isomerization of t-2-AQE in the singlet manifold. As solvent polarity is increased, Φf of c-2-AQE is greatly reduced, but Φc →t is practically independent of solvent polarity. Dual fluorescence in t-2-AQE was observed and two fluorescing species could be assigned t-2-AQE and c-2-AQE, where the ratio between two species was dependent on the solvent polarity. Interestingly, in the concentration above 1×10 -4 M, the shapes of the fluorescence excitation spectra of t- and c-2-AQE are significantly altered without spectral changes of their fluorescence and absorption, probably due to the formation of excimer.

Miniaturized Fluorometer Based on Total Internal Reflector and Condensing Mirror

  • Jang, Dae-Ho;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.81-85
    • /
    • 2013
  • A miniaturized fluorescence detection system based on total internal reflection (TIR) configuration, which is applicable to detecting the presence of biological materials labeled with fluorescence dye in micro total analysis systems (${\mu}TAS$), is proposed. In conventional fluorescence testing and analysis devices, interference between the excitation light beam and the emitted light from dyes is unavoidable. This paper presents a fluorescence detection system based on TIR configuration that allows the excitation light beam and the emitted light to be spatially perpendicular to each other so as to minimize the interference where fluorescence emission is detected at the orthogonal angle to the excitation beam. We achieved the limit of detection of about 5 nmol/L with a high linearity of 0.994 over a wide range of 6-FAM mol concentration, being comparable to that in earlier studies.

MEASUREMENT OF PESTICIDES RESIDUES USING SPECTROSCOPY ON AGRICULTURAL PRODUCTS

  • Kim, Y. W.;S. H. Noh
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.525-532
    • /
    • 2000
  • A new spectroscopic method for pesticide residues detection on agricultural products was developed. The general determination methods are high performance liquid chromatography (HPLC), gas chromatography (GC) or GC-mass spectrometry. They have provided relatively good detection limit and accuracy with complicated and time-consuming (5hrs above) procedures. In addition freshness is very important for evaluating qualities of agricultural products. This requires a simple and fast method for detection of pesticides. Reflectance, transmittance and fluorescence spectrometry of pesticides were tested using UV range because most of pesticides contain conjugation band in the molecular structures. Fluorescence spectrometry showed better sensitive to detect pesticide residues than did reflectance and transmittance spectrometry. Intensity and shape of fluorescence spectra showed different patterns with different structures of pesticides. Detection limit for fluorescence spectrometry was 0.1 ppm to 10 ppm depending on the structures of pesticides. Application of fluorescence spectrometry appears to be an easy method for detection of pesticide residues on agricultural products.

  • PDF

세대별 QLF 기기의 평활면 비와동형 법랑질 우식 병소 탐지에 관한 진단정확도 비교 (Comparison of fluorescence loss measurements among various generations of QLF devices)

  • 박석우;이형석;김상겸;이은송;;김백일
    • 대한치과의사협회지
    • /
    • 제56권1호
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The aim of in vitro study was to compare the diagnostic accuracy to detect non-cavitated enamel caries on smooth surface by using four kinds of the QLF devices. Materials and Methods: A total of 52 human permanent premolars and molars were used. Fluorescence images were captured by the QLF devices (Inspektor Pro, QLF-D, Qraycam, and Qraypen). Fluorescence loss of the QLF was calculated. The severity of lesions was categorized into the following 3 scores using polarized light microscopy: normal (S), enamel demineralization to outer half of enamel (D1), and inner half of the enamel up to the dentin-enamel junction (D2). The Kruskal-Wallis test was used to compare the fluorescence loss among the QLF devices. Spearman rank correlation coefficient between histological scores and fluorescence loss of the devices was calculated. The sensitivity, specificity, and area under the receiver operating curve (AUROC) were calculated to compare their diagnostic accuracies. Results: The correlation coefficients between histological scores and the fluorescence loss of the devices showed 0.77 to 0.81 (P < 0.001). All histological scores, the fluorescence loss among the devices showed no statistical difference. Among the devices, sensitivity, specificity, and AUC values of the fluorescence loss showed 0.84 to 0.94, 0.76 to 0.90, and 0.90 to 0.92, respectively. Conclusions: All QLF devices had no difference with excellent diagnostic accuracies to detect non-cavitated enamel caries on smooth surface.

  • PDF

Indocyanine green 형광조영제의 형광발현을 위한 농도 범위 분석 (Concentration Range Analysis for Fluorescence Expression of Indocyanine Green)

  • 김용재;이다애;윤기철;김광기
    • 한국멀티미디어학회논문지
    • /
    • 제22권12호
    • /
    • pp.1339-1346
    • /
    • 2019
  • In the characteristic of the brain malignant, the blood vessels and tumors have the same color and shape, and the boundary distinction is not clear, Therefore, it is difficult to observe the naked eye. Because of the high invasiveness, the risk of recurrence is high. Therefore, complete resection of the tumor is essential. The method for distinguishing the boundary between blood vessels and tumors is a fluorescence contrast method using indocyanine green (ICG), a fluorescence contrast agent. In ICG, the concentration range analysis is very important because the fluorescence expression state varies depending on the concentration. However, since the analysis result of the fluorescence expression condition is insufficient according to the current concentration, this paper proposes by analyzing the initial protocol of the concentration range. 780 nm infrared light was irradiated to the ICG sample to observe the fluorescence expression through a near infrared (NIR) camera. The wavelength is measured by using a spectrum instrument (ocean view) to observe the fluorescence expression wavelength of 811nm. As a result of analyzing the mol concentration according to each sample, the fluorescence expression range was found to be 16.15-0.16M and the optimum fluorescence concentration on the brightest part was found to be 3.23-0.81M.

Use of Chlorophyll a Fluorescence Imaging for Photochemical Stress Assessment in Maize (Zea mays L.) Leaf under Hot Air Condition

  • Park, Jong Yong;Yoo, Sung Young;Kang, Hong Gyu;Kim, Tae Wan
    • 한국작물학회지
    • /
    • 제61권4호
    • /
    • pp.270-276
    • /
    • 2016
  • The objective of this study was to find a rapid determination of the hot air stress in maize (Zea mays L.) leaves using a portable chlorophyll fluorescence imaging instrument. To assess the photosynthetic activity of maize leaves, an imaging analysis of the photochemical responses of maize was performed with chlorophyll fluorescence camera. The observed chlorophyll imaging photos were numerically transformed to the photochemical parameters on the basis of chlorophyll a fluorescence. Chlorophyll a fluorescence imaging (CFI) method showed that a rapid decrease in maximum fluorescence intensity ($F_m$) of leaf occurred under hot air stress. Although no change was observed in the maximum quantum yield ($F_v/F_m$) of the hot air stressed maize leaves, the other photochemical parameters such as maximum fluorescence intensity ($F_m$) and Maximum fluorescence value ($F_p$) were relatively lowered after hot air stress. In hot air stressed maize leaves, an increase was observed in the nonphotoquenching (NPQ) and decrease in the effective quantum yield of photochemical energy conversion in photosystem II (${\Phi}PSII$). Thus, NPQ and ${\Phi}PSII$ were available to be determined non-destructively in maize leaves under hot air stress. Our results clearly indicated that the hot air could be a source of stress in maize leaves. Thus, the CFI analysis along with its related parameters can be used as a rapid indicating technique for the determining hot air stress in plants.

형광입자들의 크기와 농도에 따른 형광 상관 분광함수 측정 (Measurement of Fluorescence Correlation Function by Using Size and Concentration of Fluorescence Particles)

  • 한예슬;이재란;김석원
    • 한국광학회지
    • /
    • 제23권3호
    • /
    • pp.113-118
    • /
    • 2012
  • 형광입자의 크기와 수에 따라 형광 신호의 상관함수 변화를 측정하는 형광상관분광법을 이용하여 용액 내에서 확산 운동하는 나노크기 형광 입자들의 농도와 유체역학적 반지름을 비교하였다. 시료에 사용된 나노크기 형광 입자들은 Alexa Fluor 647, 양자점, 형광 bead이고, 증류수에서 1/10, 1/100로 입자들이 들어있는 용액을 희석하여 각 입자들에 대해 3가지의 다른 농도의 시료를 준비하였다. Alex Fluor 647의 알려져 있는 확산시간을 이용하여 형광상관분광장치의 유효초점 부피를 구하고, 각 입자들의 확산계수, 크기, 희석에 따른 농도 변화를 측정할 수 있었다. 본 연구를 통해, 자체 제작된 형광상관분광장치로 임의적으로 희석된 시료들의 농도를 약 0.1 nM ~ 10 nM의 범위에서 측정할 수 있었고, 양자점의 확산계수를 $27{\pm}1{\mu}m^2/s$로 결정할 수 있었다.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Comparison of Clinical Characteristics of Fluorescence in Quantitative Light-Induced Fluorescence Images according to the Maturation Level of Dental Plaque

  • Jung, Eun-Ha;Oh, Hye-Young
    • 치위생과학회지
    • /
    • 제21권4호
    • /
    • pp.219-226
    • /
    • 2021
  • Background: Proper detection and management of dental plaque are essential for individual oral health. We aimed to evaluate the maturation level of dental plaque using a two-tone disclosing agent and to compare it with the fluorescence of dental plaque on the quantitative light-induced fluorescence (QLF) image to obtain primary data for the development of a new dental plaque scoring system. Methods: Twenty-eight subjects who consented to participate after understanding the purpose of the study were screened. The images of the anterior teeth were obtained using the QLF device. Subsequently, dental plaque was stained with a two-tone disclosing solution and a photograph was obtained with a digital single-lens reflex (DSLR) camera. The staining scores were assigned as follows: 0 for no staining, 1 for pink staining, and 2 for blue staining. The marked points on the DSLR images were selected for RGB color analysis. The relationship between dental plaque maturation and the red/green (R/G) ratio was evaluated using Spearman's rank correlation. Additionally, different red fluorescence values according to dental plaque accumulation were assessed using one-way analysis of variance followed by Scheffe's post-hoc test to identify statistically significant differences between the groups. Results: A comparison of the intensity of red fluorescence according to the maturation of the two-tone stained dental plaque confirmed that R/G ratio was higher in the QLF images with dental plaque maturation (p<0.001). Correlation analysis between the stained dental plaque and the red fluorescence intensity in the QLF image confirmed an excellent positive correlation (p<0.001). Conclusion: A new plaque scoring system can be developed based on the results of the present study. In addition, these study results may also help in dental plaque management in the clinical setting.