• Title/Summary/Keyword: Fluence

Search Result 380, Processing Time 0.032 seconds

Development of an Efficient In Vitro Screening Method for Selection of Resistant Lily Cultivars Against Fusarium oxysporum f. sp. lilii (백합 구근부패병 저항성 검정을 위한 기내 간편 검정법 개발)

  • Jang, Ji-Young;Moon, Ki-Beom;Ha, Jang-Ho;Park, Ji-Sun;Kim, Mi-Jin;Jeon, Jae-Heung;Lee, Geung-Joo;Kim, Hyun-Soon
    • Horticultural Science & Technology
    • /
    • v.33 no.6
    • /
    • pp.883-890
    • /
    • 2015
  • The soilborne fungus Fusarium oxysporum f. sp. lilii (Fol) is a serious threat to all lily cultivars, especially infecting bulbs and flowers. It has become increasingly important to develop varieties resistant against the bulb rot disease. Genetic diversity of cultivars and reliable screening methods are required for this purpose. Here, an efficient in vitro screening system for evaluating resistance to Fol in 38 in vitro-grown lily plants was investigated. Various factors including culture conditions of Fol, inoculum density, appropriate plant materials, inoculation method and duration, and incubation period of plant materials after inoculation were combined to optimize the screening method. As a result, we suggest optimal conditions for an in vitro screening system for the selection of Fol-resistant lily cultivars as follows. Fol was grown on potato dextrose agar (PDA) medium for 6 days at $25^{\circ}C$ in darkness and used as working inoculation. Spore suspensions were prepared (inoculum density: $1.0{\times}10^4$ $spores{\cdot}mL^{-1}$), and then leaf segments $1.5{\times}2.0cm^2$ were inoculated by dipping for 22 hours at $25^{\circ}C$ in dark. Later, leaves were cultured on 0.6% agar plates at $25^{\circ}C$ and 50% humidity with a photoperiod of 16 hours light/8 hours dark (fluence rate of $40{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) to examine the progress of bulb rot. After 7 days, disease levels were classified into indices 1 (no symptom) to 6 (serious bulb rot). Soil inoculation of Fol carried out with resistant or susceptible lily cultivars that had been selected through in vitro screening confirmed the reproducibility of results. Therefore, the in vitro screening method established in this study is efficient and reliable for selection of lily cultivars resistant against bulb rot disease.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter (연(鉛)필터의 투과선량을 이용한 15 MV X선의 에너지스펙트럼 결정과 조직선량 비교)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2008
  • Recent radiotherapy dose planning system (RTPS) generally adapted the kernel beam using the convolution method for computation of tissue dose. To get a depth and profile dose in a given depth concerened a given photon beam, the energy spectrum was reconstructed from the attenuation dose of transmission of filter through iterative numerical analysis. The experiments were performed with 15 MV X rays (Oncor, Siemens) and ionization chamber (0.125 cc, PTW) for measurements of filter transmitted dose. The energy spectrum of 15MV X-rays was determined from attenuated dose of lead filter transmission from 0.51 cm to 8.04 cm with energy interval 0.25 MeV. In the results, the peak flux revealed at 3.75 MeV and mean energy of 15 MV X rays was 4.639 MeV in this experiments. The results of transmitted dose of lead filter showed within 0.6% in average but maximum 2.5% discrepancy in a 5 cm thickness of lead filter. Since the tissue dose is highly depend on the its energy, the lateral dose are delivered from the lateral spread of energy fluence through flattening filter shape as tangent 0.075 and 0.125 which showed 4.211 MeV and 3.906 MeV. In this experiments, analyzed the energy spectrum has applied to obtain the percent depth dose of RTPS (XiO, Version 4.3.1, CMS). The generated percent depth dose from $6{\times}6cm^2$ of field to $30{\times}30cm^2$ showed very close to that of experimental measurement within 1 % discrepancy in average. The computed dose profile were within 1% discrepancy to measurement in field size $10{\times}10cm$, however, the large field sizes were obtained within 2% uncertainty. The resulting algorithm produced x-ray spectrum that match both quality and quantity with small discrepancy in this experiments.

  • PDF

The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams (다엽제한기 소조사면의 6 MV 광자선 출력선량계수)

  • Lee, Ho Joon;Choi, Tae-Jin;Oh, Young Kee;Jeun, Kyung Soo;Lee, Yong Hee;Kim, Jin Hee;Kim, Ok Bae;Oh, Se An;Kim, Sung Kyu;Ye, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • The IMRT is proper implement to get high dose deliver to tumor as its shape and selective approach in radiation therapy. Since the IMRT is performed as modulated the radiation fluence by the MLC created the open shapes and its irradiation time, the dose of segment of radiation field effects on the cumulated portal dose. The accurate output factor of small and step shape of segment is important to improve the determination of deliver tumor dose as it is directly proportional to dose. This experiment performed with the 6 MV photon beam of Clinac Ex(Varian) from $3{\times}3cm^2$ to $0.5{\times}0.5cm^2$ small field size for collimator jaw in MLC free and/or for MLC open field in fixed collimator jaw $10{\times}10cm^2$ using the CC01 ion chamber, SFD diode, diamond detector and X-Omat film dosimetry. As results of normalized to the reference field of $10{\times}10cm^2$ of MLC, the output factor of $3{\times}3cm^2$ showed $0.899{\pm}0.0106$, $0.855{\pm}0.0106$ for $2{\times}2cm^2$, $0.764{\pm}0.0082$ for $1{\times}1cm^2$ and $0.602{\pm}0.0399$ for $0.5{\times}0.5cm^2$. The output factor of MLC open field has shown a maximum 3.8% higher than that of the collimator jaw open field.

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

Serotype and Leukotoxic Strain Distribution of Actinobacillus(Haemophilus) Actinomycetemcomitans in Korean Localized Juvenile Periodontitis (한국인 국소 유년성 치주염환자의 Actinobacillus(Haemophilus) Actinomycetemcomitans 혈청형 및 백혈구독성 균주 분포)

  • Chung, Hyun-Ju;Chung, Chong-Pyoung;Son, Seong-Heui
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.4
    • /
    • pp.487-501
    • /
    • 1986
  • Previous studies from our laboratory suggested that Korean LJP patients might habor A. actinomycetemcomitans of different serotype from Caucasian LJP patients in whom serotype b was predominant. In order to observe the prevalence and serotype distribution of A. actinomycetemcomitans in localized juvenile periodontitis patients and to evaluate leukotoxic activity of oral isolates, this study was performed. A. actinomycetemcomitans was isolated by using a selective medium(tryptic soy agar supplemented with 10% serum, $75{\mu}g$ of bacitracin and $5{\mu}g$ of vancomycin per ml). Using immunoabsorbed, ammonium sulfate-fractionated serotype-specific antisera, a total of 69 strains were serologically categorized by ELISA. Leukotoxicity was monitored biochemically by measuring lactate dehydrogenase indicator of cell viability in culture supernatant of PMNL plus viable A. actinomycetemcomitans mixture. The results were as follows: 1. A. actinomycetemcomitans was detected in 75% of 16 LJP patients, and 71% in the LJP lesions and 6% in the control sites. 2. Presence or absence of A. actinomycetemcomitans in the sampled disease sites has no in fluence on clinical measurements. 3. Three serotypes were approximately equally distributed in overall 9 patients. Three patients harbored 2 different serotypes of A. actinomycetemcomitans in the same disease site or different disease sites. 4. The proportion of leukotoxic oral isolates was 22% of a total of 46 strains and the prevalence was 69% in 13 sampled sites. The same disease site could harbor both leukotoxic and nonleukotoxic strains. 5. Distribution of leukotoxic strains in 3 serotypes were not different.

  • PDF

Analysis to the Essential Factors of Humor Emerging in Chinese Cartoon Around Year of 2000 (2000년을 전후로 하여 중국 애니메이션에 나타난 유머요인 분석)

  • Dong, Peng;Oh, Jin-Hee
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.189-215
    • /
    • 2014
  • Since the launching of in 1963, a large amount of outstanding cartoons had been produced in China by the year 1980. During this period of time, international reputation was achieved with the extremely full expression and characteristic stories originated from Chinese culture. Decades of cartoons were produced ever year benefiting from support of the government in the last years. However, the quality and in fluence power dropped down comparing with the increasing productivity. The outward followed by examples of successful international box office most of the animation made in China. These cartoons did not obtain admitting internationally, or disclose any traditional speciality of China, although the domestic box office is considered to be fairly successful. The key factors to the successful cases should be analysed and researched rather than simply estimating, in order to achieve both artistic and commercial success. Factor of humor, as a key element of a successful cartoon is proposed in this thesis. Prior to the discussion, a general definition of humor factor is described through Henri Bergson's comedy concept, based on which the key factors of humor will be analysed. A classification system would be derived and introduced as a tool for the analysis of humor factors. According to Henri Bergson, Humor is determined by circumstance, language and character factors. Humor factors are divided into visual, scene and acoustic factors in this research taking the Speciality of cartoon media into consideration. It is the speciality that, in addition to the visual and language factors, multiple acoustic elements are also introduced in such a presentation pattern. This classification system would be considerably applicable to the analysis of humor factors in Chinese cartoons. In this study, around the year 2000 to share the Chinese animation masterpiece were analyzed by selecting and , and . This discussion about key factors of humor is likely to be beneficial to the development of Chinese Cartoons in the future.

A Study on Conventional Expression of Hangul Ganchal and Email (조선시대 한글 간찰과 이메일의 상투적 표현 고찰)

  • Jeon, Byeong-yong
    • (The)Study of the Eastern Classic
    • /
    • no.49
    • /
    • pp.431-459
    • /
    • 2012
  • The purpose of this article is to compare and analyze the conventional expression of Hangul Ganchal in Cheosun Dynasty and Email. Conventional expression is used remarkably in introductions and conclusions. In introduction, it is used for addressing and safety greetings while in conclusion, it is used for closing address and closing words. In Cheosun Dynasty, an envelope of Ganchal only included the details of the receiver because the letter was genuinely delivered by someone who knew the receiver and the sender very well. An envelope of Ganchal is applicable to the screen of the internet which is used for emailing. In an email, we see the name of the sender and the title of the text and once we click the title, we are able to view the text. The difference between the Ganchal and the email was reflected on how the receiver's detail showed on Ganchal and the email show the sender's details. In a case of addressing in a letter while using the conventional expression, we can see how we use "To~" in humble term and " ~께" in a honorific term. We confirmed that the conventional expression has not yet settled in both of the Gnachal and email for the seasonal greetings. The safety greetings comprised with both of the senders' and receivers' latest updates. In Ganchal, this composition is well described conventionally, whereas in emails, only the receivers' latest news are written but the senders' latest updates are hard to be seen throughout the text. In Ganchal's closing section, the closing address and closing words were expressed conventionally. However, in the case of email; those were again hard to be found throughout. To conclude, in Ganchal the conventional expression was developed and placed in 16thcentury(Sun-eon) when there was a focus in our native language. In 17thcentury(Hyeon-eon), it stood still for a sometime and moved on to 19thcentury(Jing-eon) when there was a strong in fluence of Hangul Ganchal, which resulted in regression to the conservative expression. In general, we are able to confirm that the conventional expression is slowly disappearing.