• 제목/요약/키워드: Flowrate Measurement

검색결과 42건 처리시간 0.021초

복합 관수로에서 인버스 임피던스 확장연구 (Extended inverse impedance method for multiple branches or loops pipeline systems)

  • 고동원;김상현
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.437-446
    • /
    • 2023
  • We propose a transient evaluation scheme using a pressure measurement in a complicate pipeline systems. Conservation of mass and momentum equations in time domain can be transformed into a pressure head and flowrate relationship between upstream and downstream point in frequency domain. The impedance formulations were derived to address measured pressure at downstream to evaluate of flowrate or pressure head at any point of system. Both branched pipeline element and looped pipeline element can be generally addressed in the platform of the basic reservoir pipeline valve system. The convolution of time domain response function with measured pressure head from a downstream point provides flowrate or pressure head response in any point of the designated pipeline system. The proposed method was validated through comparison between traditional method of characteristics and the proposed method in several hypothetical systems.

2중판 오리피스를 이용한 기액 2상유량계의 개발 (Development of a 9as-liquid two-phase flowmeter using double orifice plates)

  • 이상천;이상무;남상철
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF

소형 축류터빈의 상온 성능시험기 개발 (Development of a Test Facility for Cold-air Performance of Small Axial Turbine)

  • 손창민;차봉준;이대성
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1780-1786
    • /
    • 1995
  • The main goal of the present study is to establish the techniques and methodolgies of turbine performance test through evaluating the objective turbine test piece, and checking the reliability of the self-developed test facility by performing a series of turbine tests under ambient temperature condition. A high speed coupling, a lubrication system and a test bed of the test facility were modified through a series of preliminary test in order to reduce the vibration and oil leakage. The flowrate control of the test facility and data acquisition were accomplished by using a software called "Labview" The measurement of shaft horse power and control of rotational speed according to the conditions of turbine rotation were performed by a separate system. The preliminary evaluation of the measured data suggests that the developed test facility and the test technique can be used reliably for the performance test of turbines with the minor improvement.provement.

유압관로에서 원통형 초크의 비정상 유동의 주파수 특성에 관한 연구 (Frequency Characteristics of Unsteady Flow of Cylindrical Choke in a Hydraulic Pipe)

  • 박선종;유영태;위광환
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.421-434
    • /
    • 1995
  • A new instantaneous flowmeter for hydraulics by means or cylindrical chokes is developed. In this method the instantaneous flowrate through chokes is predicted in real time from measurement of pressure difference on both sides of cylindrical choke. The experimental study for the flowrate of pulsating flow in a pipe is carried out to measure differential pressure drop by using a strain gauge pressure transducer with data acquisition and processing system. A pulsating flow is verified by a visualization method. In the present study, the flow characteristic variables of laminar pulsating flow are investigated analytically and experimentally in a circular pipe. Characteristic parameters of ratio of inertia term to pressure term($\phi_{t.1}$) and ratio of viscous term to pressure term($\phi_{z.1}$) are introduced to describe the flow pattern of laminar pulsating flow.

  • PDF

3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

Accuracy Analysis of Ultrasonic, Magnetic and Radar Sensors for Manhole Monitoring

  • Khatatbeh, Arwa;Kim, Young-Oh;Kim, Hyeonju
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.427-427
    • /
    • 2021
  • During the rainy season, heavy downpours are always a source of concern for the world. Flooding and heavy rains can devastate communities, disrupt agriculture, and contribute to traffic accidents.. Weir and flow hall effect sensors are the conventional analytical methods for measuring flow rate; in this paper, we analyzed manhole flowrate statistics. The measurement of the flow rate of a notch/weir is a time-consuming task that necessitates continuous mathematical analysis. . We created three types of IoT sensors in this study: (HC-SR04 ultrasonic, YF-S201 magnetic, and HB100 radar), which take the sensor's real-time input signal and estimate the flow using a notch equation and a previously calibrated optimized coefficient of discharge. The proposed systems are cost-effective, but in terms of accuracy, we found that the HC-SR04 ultrasonic sensor is the best of the three systems

  • PDF

열량형 질량유량계에 대한 압력과 비열 영향 (The Effects of Pressure and Specific Heat on the Performance of Thermal Mass Flowmeter)

  • 최용문;박경암;최해만;이기성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.109-113
    • /
    • 1999
  • Thermal mass flow meter (TMF) is used measuring the small mass flow rate of gases. Generally, flow rate measuring accuracy of TMF is $\pm2{\%}$ of full scale. TMF is manufactured for specified working pressure and specified working gas by customer. If it were applied for different working pressure and gases, flow rate measurement accuracy decreased dramatically. In this study, a TMF tested with three different gases and pressure range of 0.2 MPa to 1.0 MPa. Effect of specific heat cause to increase flow measurement error as much as ratio of specific heat compare with reference gas. Pressure change cause to increase flowrate measurement deviation about $-0.2{\%}$ as the working pressure decreased 0.1 MPa.

  • PDF

Segmental Wedge를 이용한 차압식 유량측정 방법 (Flowrate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure)

  • 윤준용;성낙원
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.302-307
    • /
    • 2005
  • The discharge coefficient in segmental wedge having ninety degrees vertex angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured main purpose of this work is placed on developing the proper form of an equation for the discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and from thata six-term equation which can express the variability of opening ratios was developed. The same assumption and hypotheses were used and tested for all procedures as conventional differential producers; however, the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated the Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000, the resulting equation for the discharge coefficient is relatively simple; it contains only one variable-opening ratio because the characteristic of discharge coefficient of segmental wedge has little connection with the Reynolds number as shown by previous studies.

  • PDF

피압 단순 관로 체제에서의 인버스 임피던스를 이용한 수압기반 유속추정기술 (A pressure based flow velocity estimation technique using inverse impedance for simple pressurized pipeline systems)

  • 이정섭;고동원;최두용;김상현
    • 상하수도학회지
    • /
    • 제36권4호
    • /
    • pp.219-228
    • /
    • 2022
  • In this study, we propose a flow velocity evaluation scheme based on pressure measurement in pressurized pipeline systems. Conservation of mass and momentum equations can be decomposed into mean and perturbation of pressure head and flowrate, which provide the pressure head and flowrate relationship between upstream and donwstream point in pressurized pipeline system. The inverse impedance formulations were derived to address measured pressure at downstream to evaluation of flow velocity or pressure at any point of system. The convolution of response function to pressure head in downstream valve provides the flow velocity response in any point of the simple pipeline system. Simulation comparison between traditional method of characteristics and the proposed method provide good agreements between two distinct approaches.

공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향 (Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation)

  • 이천환;김민영;이수민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.77-82
    • /
    • 2023
  • The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.