DOI QR코드

DOI QR Code

공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향

Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation

  • 이천환 (전남대학교 지능형모빌리티융합학과) ;
  • 김민영 (전남대학교 대학원 기계공학부) ;
  • 이수민 (전남대학교 대학원 기계공학부)
  • CHUNHWAN LEE (Department of Intelligent Mobility, College of AI Convergence, Chonnam National University) ;
  • MINYOUNG KIM (Department of Mechanical Engineering, Chonnam National University Graduate School) ;
  • SUMIN LEE (Department of Mechanical Engineering, Chonnam National University Graduate School)
  • 투고 : 2023.01.25
  • 심사 : 2023.02.14
  • 발행 : 2023.02.28

초록

The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.

키워드

과제정보

본 연구는 산업통상자원부 한국산업단지공단의 자동차용 복합기능 에어크리너 공정기술 최적화 개발사업의 연구결과로 수행되었음(IRGJ2204).

참고문헌

  1. B. N. Lee, A. Kodir1, H. Lee, D. Shin, and B. Bae, "Preparation and characterization of the polymeric antioxidant for improving the chemical durability of polymer electrolyte mem branes", Trans Korean Hydrogen New Energy Soc, Vol. 32, No. 5, 2021, pp. 308-314, doi: https://doi.org/10.7316/KHNES.2021.32.5.308.
  2. M. H. Yi, J. S. Choi, and B. Roh, "Synthesis and durability of carbon-supported catalysts for PEMFC", Trans Korean Hydrogen New Energy Soc, Vol. 26, No. 4, 2015, pp. 318-323, doi: https://doi.org/10.7316/KHNES.2015.26.4.318.
  3. J. Park, H. Oh, J. Cho, K. Min, E. Lee, and J. Y. Jyoung, "Study on the durability characteristics of the PEM Fuel cells having gas diffusion layer with different micro porous layer penetration thicknesses", Trans Korean Hydrogen New Energy Soc, Vol. 24, No. 3, 2013, pp. 216-222, doi: https://doi.org/10.7316/KHNES.2013.24.3.216.
  4. T. Doiron, "20 ℃-a short history of the standard reference temperature for industrial dimensional measurements", Journal of research of the National Institute of Standards and Technology, Vol. 112, No. 1, 2007, pp. 1-23, doi: https://doi.org/10.6028/jres.112.001.
  5. C. Lee, B. Kim, J. Kang, H. Lee, and T. Cho, "Automatic test system development for automobile air cleaner", KSAE 2000 Annual Conference, 2000, pp. 659-664. Retrived from https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE00526660.
  6. C. Lee, B. Kim, S. Shim, S. Ahn, and T. Cho, "Reliability test for different types of air cleaner test system", KSAE 2000 Annual Conference, 2000, pp. 673-678. Retrieved from https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE00526662.