• 제목/요약/키워드: Flow artifact

검색결과 26건 처리시간 0.024초

Intra-Motion Compensation Using CSRS method in MRI

  • Ro, Y.M.;Yi, J.H.;Cho, Z.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.377-382
    • /
    • 1994
  • In the conventional Fourier imaging method in MRI (Magnetic Resonance Imaging), intramotion such as pulsatile flow makes zipper-like artifact along the phase encoding direction. On the other hand, line-integral projection reconstruction (LPR) method has advantages such as imaging of short T2, object and reduction of the flow artifact by elimination of the flow-induced phase fluctuation. The LPR, however, necessarily requires time consuming filtering and back-projection processes, so that the reconstruction takes long time. To overcome the long reconstruction time of the LPR and to obtain the flow artifact reduction effect, we adopted phase corrected concentric square raster sampling (CSRS) method and improved its imaging performance. The CSRS is a fast reconstruction method which has the same properties with the LPR. In this paper, we proposed a new method of flow artifact reduction using the CSRS method. Through computer simulations and experiments, we verified that the proposed method can eliminate phase fluctuations, thereby reducing the flow artifact and re- markably shorten the reconstruction time which required long time in the LPR.

  • PDF

MRI Artifacts

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.51-57
    • /
    • 1997
  • MRI의 artifact는 대부분 신호의 부호화 방향에 따라서 방향성을 가지는데, 이를 요약해보면, 위상부호화 방향의 artifact에는 motion artifact, flow artifact, RF noise등이 있고, 주파수 부호화 방향의 artfact는 susceptibility artfact, chemical shift artifact, central line artifact등이 있으며, 양방향 모두 생길수 있는 것은 Aliasing artifact와 Gibb's phenomenon이고, 전체적으로 영샹의 질을 떨어뜨리는 것은 susceptibility artifact, Eddy current, cross talk등이 있다. 이런 artifact는 대부분은 MRI 자체의 물리적 특성에 다소간 기인하므로, artifact가 없는 양호한 영상을 얻기 위해서는 MRI의 설치 단계부터 관심이 필요하고, MRI의 기본원리와 다양한 artifact에 대해 이해함으로써, 제거 가능한 artifact는 제거하여 양질의 영상을 만들고 판독시의 오류를 피할 수 있도록 해야할 것이다.

  • PDF

Filter- and Denuder-Based Organic Carbon Correction for Positive Sampling Artifacts

  • Hwang, InJo;Na, Kwangsam
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권2호
    • /
    • pp.107-113
    • /
    • 2017
  • This study describes (1) the impact of positive sampling artifacts caused by not only a filter-based sampling, but also a denuder-based sampling in the determination of particle-phase organic carbon (POC), (2) the effect of sample flow rate on positive artifacts, and (3) an optimum flow rate that provides a minimized negative sampling artifact for the denuder-based sampling method. To achieve the goals of this study, four different sampling media combinations were employed: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), (3) quartz filter and quartz filter behind Teflon filter (Q-QBT), and (4) quartz filter behind carbon-based denuder (Denuder-Q). The measurement of ambient POC was carried out in an urban area. In addition, to determine gas-phase OC (GOC) removal efficiency of the denuder, a Teflon filter and a quartz filter were deployed upstream and downstream of the denuder, respectively with varying sample flow rates: 5, 10, 20, and 30 LPM. It was found that Q-alone sampling configuration showed a higher POC than QBQ, Q-QBT, and Denuder-Q by 12%, 28%, and 23%, respectively at a sample flow rate of 20 LPM due to no correction for positive artifact caused by adsorption of GOC onto the filter. A lower quantity of GOC was collected from the backup quartz filter on QBQ than that from Q-QBT. This was because GOC was not in equilibrium with that adsorbed on the front quartz filter of QBQ during the sampling period. It is observed that the loss of particle number and mass across the denuder increases with decreasing sample flow rate. The contribution o f positive arti facts to POC decreased with increasing sample flow rate, showing 29%, 25%, and 22% for 10, 20, and 30 LPM, respectively. The 20 LPM turns out to be the optimum sample flow rate for both filter and denuder-based POC sampling.

산소포화도(SpO2) 측정시에 발생되는 motion artifact를 reduction하는 algorithm (Algorithm for reduction of motion artifact generated in SpO2 measurement)

  • 한승헌;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.860-863
    • /
    • 2003
  • 산소포화도 측정은 Beer-Lambert's law를 기초로하여 측정 부위(손가락, 귀 등)에 LED를 발광한 후 투과된 적생광과 적외선광 신호가 통과하고 photodetector에서 감지한 후 나타난 두 광의 비율로 계산한다. Pulse oximetry는 이러한 산소포화도를 측정하는 기기인데, 근데 아주 민감하기 때문에 압력이 적절한 조직 혈류로 공급하기 어려울 정도로 아주 낮을 때 펄스를 검출한다. 다시말해서, SpO2는 혈관 수축이나 저혈압에서의 흐르지 않는 동맥혈의 펄싱의 손가락에 의한 O2소모 때문에 감소할 수도 있다. 이러한 점에서 측정 결과시의 한계가 있다. 따라서 본 논문은 SpO2를 측정할 때 어떠한 움직에 의해 나타나는 motion artifact를 최소화하는 알고리즘을 고찰하였다.

  • PDF

삼상 골신티그래피상 자궁내장치의 광자감쇠현상에 의해 생긴 Uterine Doughnut: 인공물 (Uterine Doughnut by Intrauterine Device-induced Photon Attenuation on Three-Phase Bone Scintigraphy : Artifact)

  • 손명희;정환정;임석태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.68-69
    • /
    • 2007
  • A 44-year-old female underwent three-phase bone scintigraphy for an evaluation of right hip joint pain. The blood-flow and blood-pool images show a pelvic blush with a photopenic center (doughnut) prior to bladder filling. On the three hour delayed image, the pelvic uptake disappeared. The scintigraphic findings indicated the possibility of an early pregnancy. However, plain radiography demonstrated an intrauterine device. A uterine doughnut developed as a result of photon attenuation of intrauterine device.

동잡음 저감을 위한 심전도 전극 특성에 대한 연구 (Study on Characteristics of ECG Electrodes for Motion Artifact Reduction)

  • 강영환;박재순;조범기;최상동;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

2D TOF 자기공명 혈관조영술에서 동맥혈류의 역류로 인한 영상훼손과 이의 제거 (Artifacts due to Retrograde Flow in the Artery and Their Elimination in 2D TOF MR Angiography)

  • 정관진;이종권;김선경;박성홍
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.38-42
    • /
    • 2001
  • 2D TOF혈관조영술에서 presaturation RF펄스를 사용하여 정맥피에서 나오는 MR신호를 제거하고 얻은 동맥 angiogram에는 band형태로 동맥이 끊어져 나타나는 현상이 자주 보인다. 일부 동맥에서 피의 흐름은 한 심장 주기 동안에 3번의 펄스를 갖는데, 이 중 가운데 펄스는 짧은 기간 동안 역류를 한다. 이 역류하는 동맥피는 정맥피와 같은 방향이기 때문에 presaturation RF펄스에 의해 정맥피 처럼 saturation이 되어서 imaging slice로 흘러 들어가게 될 수 있다. 특히 이러한 경우가 phase encoding step의 dc 부근에서 발생하게 되면 그 때의 단면 영상에서 동맥이 강조가 될 수 없게 되어, 결과적으로 angiogram에는 그 단면을 지나는 동맥의 신호가 없어서 band 형태로 핏줄이 끊어져 나타나게 된다. Imaging slice와 saturation band와의 간격을 변화 시켜 가면서 angiogram을 얻어 봄으로서 이러한 현상을 실험적으로 확인하였다 나아가 saturation band를 rectangle형태에서 ramp 형태로 변경함으로써 이러한 artifacts를 제거 할 수 있는 방법을 제시하였다

  • PDF

CT characteristics of normal canine pulmonary arteries and evaluation of optimal contrast delivery methods in CT pulmonary angiography

  • Jung, Joohyun;Chang, Jinhwa;Yoon, Junghee;Choi, Mincheol
    • 대한수의학회지
    • /
    • 제47권2호
    • /
    • pp.247-254
    • /
    • 2007
  • This study was performed to identify the normal anatomic orientation of pulmonary arteries and to obtain the normal baseline parameters and the optimal contrast material delivery methods of computed tomographic pulmonary angiography (CTPA) on normal beagle dogs. Based on the contrast injection flow rate, the contrast volume, and the administration methods, the experimental groups were divided into 4 groups such as group 1 : 2 ml/s, 3 ml/kg, and monophasic administration; group 2 : 5 ml/s, 3 ml/kg, and monophasic administration; group 3 : 5 ml/s, 4 ml/kg, and monophasic administration; group 4 : 5 ml/s and 2 ml/kg in first phase, 0.3 ml/s and 2 ml/kg in second phase, as biphasic administration. Normal anatomic orientation of pulmonary arteries in CTPA was evaluated through reformatted and 3D images after retro-reconstruction. Normal parameters for great arteries and peripheral pulmonary arteries were obtained on the factor of basement hounsfield unit (HU) values, contrast enhanced HU values, delay time, and peak time. And the optimal contrast delivery methods were evaluated on the factor of contrast enhanced HU values, image quality, and artifact. The monophasic administration with 5 ml/s contrast injection flow rate and 3 ml/kg contrast volume was optimal in canine CTPA.

Si/$SiO_2$/NiFe/$Al_2$$O_3$/Co 박막의 투과자기저항 특성 연구 (Tunneling Magnetoresistance in Si/$SiO_2$/NiFe/$Al_2$$O_3$/Co Thin Films)

  • 현준원;백주열
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.934-940
    • /
    • 2001
  • Magnetic properties were investigated for Si/SiO$_2$/NiFe(300 )/A1$_2$O$_3$(t)/Co(200 ) junction related with the parameters of $Al_2$O$_3$. Insulating $Al_2$O$_3$ layer was formed by depositing a 5~40 thick Al layer, followed by a 90~120s RF plasma oxidation in an $O_2$ atmosphere. Magnetoresistance was not observed for tunnel junction with 5~10 thick Al layer, but magnetoresistance was observed large for tunnel junction with 15~40 thick Al layer. Oxidation time did not largely influence magnetoresistance. Tunnel magnetoresistance effect depended on magnetization behavior of two ferromagnetic layers. Tunneling junction was confirmed through nonlinear I-V curve. In this work, tunneling magnetoresistance(TMR) up to 30 % was observed. This apparent TMR is an artifact of the nonuniform current flow over the junction in the cross geometry of the electrodes.

  • PDF

Multisensory based AR System for Education of Cultural Heritage

  • Jeong, Eunsol;Oh, Jeong-eun;Won, Haeyeon;Yu, Jeongmin
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권11호
    • /
    • pp.61-69
    • /
    • 2019
  • 본 연구에서는 문화유산 교육을 위한 다중 감각 (시각 청각 촉각) 지원 기반 증강현실 시스템을 제안한다. 제안된 시스템에서는 3D프린트 된 유사유물 모델을 AR 타깃으로 활용하고, 증강하는 가상객체에는 실제유물 기반으로 구현된 3D그래픽을 매핑한다. 사용자는 3D프린트 된 모델의 촉감을 느끼면서 AR유물학습을 진행할 수 있어 다중 감각을 통한 상호작용을 경험하게 된다. 기존 문화유산 교육 시스템과 비교했을 때 본 시스템은 시각 및 청각뿐만 아니라 촉각을 제공하는데 중점을 두고 설계되었다. 또한 이 시스템은 3D모델을 사용하여 직접적인 상호작용을 제공하여, 주로 휴대전화와 태블릿의 2D 디스플레이에 터치 또는 클릭 모션으로 상호작용하는 기존 시스템보다 훨씬 사실적인 경험을 주도록 구성되었다. 사용자 테스트 결과에 따르면 본 유물교육시스템은 사용자에게 우수한 현존감 및 학습 몰입감을 제공하였으며, 타깃의 사용성 평가에서는 본래 유물과 모양이 유사한 3D 프린트 된 타깃의 사용성이 가장 좋게 평가되었다.