• Title/Summary/Keyword: Flooring materials

Search Result 103, Processing Time 0.029 seconds

Application of Field and Laboratory Emission Cell (FLEC) to Determine Formaldehyde and VOCs Emissions from Wood-Based Composites

  • Kim, Sumin;Kim, Jin-A;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.24-37
    • /
    • 2007
  • The Korean Ministry of Environment started controlling indoor air quality (IAQ) in 2004 through the introduction of a law regulating the use of pollutant emitting building materials. The use of materials with formaldehyde emission levels above $1.25 mg/m^2{\cdot}h$ (JIS A 1901, small chamber method) has been prohibited. This level is equivalent to the $E_2$ grade ($>5.0mg/{\ell}$) of the desiccator method (JIS A 1460). However, the $20{\ell}$ small chamber method requires a 7-day test time to obtain the formaldehyde and volatile organic compound (VOC) emission results from solid building interior materials. As a approach to significantly reduce the test time, the field and laboratory emission cell (FLEC) has been proposed in Europe with a total test time less than one hour. This paper assesses the reproducibility of testing formaldehyde and TVOC emissions from wood-based composites such as medium density fiberboard (MDF), laminate flooring, and engineered flooring using three methods: desiccator, perforator and FLEC. According to the desiccator and perforator standards, the formaldehyde emission level of each flooring was ${\le}E_1$ grade. The formaldehyde emission of MDF was $3.48 mg/{\ell}$ by the desiccator method and 8.57 g/100 g by the perforator method. To determine the formaldehyde emission, the peak areas of each wood-based composite were calculated from aldehyde chromatograms obtained using the FLEC method. Formaldehyde, acetaldehyde, propionaldehyde, butyraldehyde and benzaldehyde were detected as aldehyde compounds. The experimental results indicated that MDF emitted chloroform, benzene, trichloroethylene, toluene, ethylbenzene, m,p-xy-lene, styrene, and o-xylene. MDF emitted significantly greater amounts of VOCs than the floorings did.

A Study on Combustion Characteristic of the Using Wood Flooring as Wall Material (목질바닥재의 벽재사용에 따른 연소특성에 관한 연구)

  • Yoo, Ji Chang;Choi, Chul;Yang, Sung Min;Lee, Chang Goo;Kang, Seog Goo
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.1
    • /
    • pp.8-14
    • /
    • 2016
  • Increasing concerns of environment need to make change furniture field to more environmentally friendly approach, such as reuse of by-products from wooden products. As it is, the methods of recycling wood for industrial purposes have the advantage of productivity and adaptability. However, the industrial way is required a certain production facility of processing wooden by-products and has possible hygienic problems due to contaminated sources. Many designers have developed their own methods for reuse of wood in unique and artistic ways. Even so, because of confined sources, it could be not enough supply. Therefore, I developed the design methodology utilizing wooden by-products from S Design Company to relieve former ways' problems. The design suggestion took materials from a safe and abundant source. The wooden leftover pieces were connected together with epoxy clay, so previous process traces of furniture are remained as a decorative factor. Moreover, the synthesized material was able to be processed by ordinary woodworking facilities without additional installations. In doing so, console table focused on a commercial purpose and dining table for an artistic objective were successfully fabricated as final suggestions. In consideration of the proposal using wooden furniture leftovers, diverse recycling designs should be investigated for future reference.

The Evaluation of Fracture Toughness on Mode I for Twill CFRP/GFRP Laminated Hybrid Composites (능직 CFRP/GFRP 적층하이브리드 복합재의 Mode I 파괴인성 평가)

  • Roh, Young Woo;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.9-14
    • /
    • 2020
  • In order to realize high strength and light weight for various industrial facilities and structural materials, various new materials are applied to product design. Among them, CFRP has excellent specific strength and non-rigidity, and the scope of use is expanding throughout the industry, such as mobility products and building materials. GFRP is cheaper than CFRP, and has excellent specific strength and non-rigidity, and has excellent heat resistance and sound insulation, so it has been adopted as a core material for flooring and interior flooring. CFRP of twill weave structure has better resistance to deformation of fiber than plain weave structure, so the outermost layer is applied as twill weave structure in product design. After fabrication with DCB specimens, Mode I fracture toughness was evaluated according to the crack length. As the crack length increases, the energy release rate and stress intensity factor values tended to decrease overall.

Hazard Assessment of Combustion Gases from Interior Materials (주요 건축 내장재의 연소가스 유해성 평가)

  • Seo, Hyun Jeong;Son, Dong Won
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.49-56
    • /
    • 2015
  • Toxic gases from five types of interior building materials were investigated according to Naval Engineering Standard (NES) 713. The materials were plywood, indoor wall coverings (wood wall plate members and pine wood), reinforced Styrofoam insulation, laminate flooring, and PVC. Specimens were measured using an NES 713 toxicity test apparatus to analyze the hazardous substances in combustion gas from the materials. We used the US Department of Defense standard (MIL-DTL, Military Standard) to calculate the toxicity index of the combustion gas. Emissions of $CO_2$ from all specimens did not exceed the NES 713 limit of 100,000 ppm. The amount of CO gas emissions from reinforced Styrofoam insulation was 6,098 ppm. 25 ppm and 49 ppm of formaldehyde were released from the reinforced Styrofoam insulation and PVC flooring, respectively. These values were less than the limit of 400 ppm. The highest emissions were from $NO_X$ emitted by plywood and were above the limit of 250 ppm. The toxicity index of the specimens were calculated as 5.19 for plywood, 4.13 for PVC flooring, 2.35 for reinforced Styrofoam insulation, 2.34 for laminate flooring, and 1.22 for indoor wall coverings (pine wood). Our research helps us to understand the properties of these five interior materials by analyzing the combustion gas and explaining the toxicity of constituents and the toxicity index. Also, it would be useful for giving fundamentals to guide the safe use of interior materials for applications.

A Study on Deflection Characteristics of Plywood for Wood Based Flooring by Veneer Composition (마루판용 합판의 단판 구성요소에 따른 변형 특성에 관한 연구)

  • Pi, Duck-Won;Kang, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.42-50
    • /
    • 2013
  • Since 1990's, a plywood for flooring base has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as crossband layers was checked by deflection experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on deflection are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are M type of density gradient on the other hand Eucalyptus samples are W type of density gradient. The more samples have high density difference, the more deformation was checked. A sample which has big density difference between core and cross bands layer warp more also deform. Flooring was deformed smaller than plywood and samples which have big density difference was deformed more.

Static Bending Performances of Cross-Laminated Wood Panels Made with Tropical and Temperate Woods

  • Byeon, Jin-Woong;Kim, Tae-Ho;Yang, Jae-Kyung;Byeon, Hee-Seop;Park, Han-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.726-734
    • /
    • 2018
  • In this study, for using effectively domestic (temperate) small and medium diameter logs as a wooden floorboard, cross-laminated wood panels were manufactured using domestic larch and tulip woods as a base material for teak and merbau wood flooring, and static bending strength performances were measured to investigate the applicability as the base materials of wooden flooring in place of plywood. Static bending MOE was much influenced by the strength performances of the top layer lamina than that of the laminae for base materials. Bending MOR showed the higher values in tulip wood that was hardwoods than in larch wood that was softwoods regardless of the strength performances of the top layer laminae, and it was found that the values were much influenced by the strength performances of the base materials used in the core and bottom layers. However these values were 1.4-2.5 times higher values than the bending strength of the wooden floorboards specified in KS, it was found that it can be sufficiently applied to the base materials of wooden floorboards in place of plywood.

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux (건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구)

  • Park, Youngju;Kim, Youngtak
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

A study on the economic analysis of the SL(Self Leveling) Inorganic Floor covering (SL 무기질 바닥재의 경제성 분석에 관한 연구)

  • Park, Ho-Geun;Hong, Seong-Wook;Yang, Je-Yong;Kim, Sang-Won;Shin, Chan-Ho;Choe, Min-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.105-109
    • /
    • 2011
  • This study is concerned with the development of the SL inorganic floor covering. First, volatile organic compounds, inorganic test profile on the SL through the flooring is environment-friendly inorganic noncombustible floor finishes the event of fire toxic gases (such as volatile organic compounds) emissions have been identified as not at all. Second, SL-breathable material, the concrete floor to prevent aging, long life, which are three levels of noise, shock-absorbing function was decreased. Third, SL economic analysis of mineral flooring terrazzo tile floors compared with the normal material. On a terrazzo tile cost 13,500 won ~ 24,500 won, but It have found that, in terms of labor SL 36,899 won ~ 38,899 won flooring mineral balance. Occurs in the total amount when compared with terrazzo tile floors and 25,399 won 3T, 5T and economical analysis concludes that the original 12,399 won.

  • PDF

A Study on the Design Change and of the Anglican Church & Rectory in Onsuri, Ganghwa Island (강화 온수리 성공회 성당과 사제관 디자인 변형에 대한 조사연구)

  • 최정신;한주희
    • Korean Institute of Interior Design Journal
    • /
    • no.41
    • /
    • pp.11-18
    • /
    • 2003
  • This study was carried out to find the cases of change in the Anglican Church including its rectory in Onsuri, Gangwha island, which was built in Korean traditional architecture style. The materials used for the study were published books, old photos taken before the change, drawings, and field survey. The result are as followings. 1) Painting concealed natural wooden grain should be removed as well as carpet on the wooden floor. The way of ceiling finishing is to be restored as traditional way. 2) Refer to the rectory, it needs to be restored totally, since it has been changed many times through partial renovation. It lacks unification of design in entire elevation, windows and door. The practical spaces such as indoor flush toilet and boiler room are desirable not to be revealed or designed in harmony with other spaces. 3) Stript flooring in the rectory are to be restored to frame flooring, room finishing including vinyl flooring, vinyl wall paper and moulding along the cornice to the traditional paper finish. Lattice patterns of windows and doors are recommended to be restored according to the traditional design.