• 제목/요약/키워드: Floor Panel

검색결과 177건 처리시간 0.034초

Investigation of the link beam length of a coupled steel plate shear wall

  • Gholhaki, M.;Ghadaksaz, M.B.
    • Steel and Composite Structures
    • /
    • 제20권1호
    • /
    • pp.107-125
    • /
    • 2016
  • Steel shear wall system has been used in recent years in tall buildings due to its appropriate behavior advantages such as stiffness, high strength, economic feasibility and high energy absorption capability. Coupled steel plate shear walls consist of two steel shear walls that are connected to each other by steel link beam at each floor level. In this article the frames of 3, 10, and 15 of (C-SPSW) floor with rigid connection were considered in three different lengths of 1.25, 2.5 and 3.75 meters and link beams with plastic section modulus of 100% to the panel beam at each floor level and analyzed using three pairs of accelerograms based on nonlinear dynamic analysis through ABAQUS software and then the performance of walls and link beams at base shear, drift, the period of structure, degree of coupling (DC) and dissipated energy evaluated. The results show that the (C-SPSW) system base shear increases with a decrease in the link beam length, and the drift, main period and dissipated energy of structure decreases. Also the link beam length has different effects on parameters of coupling degrees.

강릉지역 전(田)자형 민가의 주생활 변화에 따른 주거공간의 변형 (The Residential Space Transformation of Vernacular Houses with 田-shaped Floor Plan according to the Housing Life Change at Gangreung Area)

  • 최장순
    • 한국농촌건축학회논문집
    • /
    • 제20권2호
    • /
    • pp.49-56
    • /
    • 2018
  • The vernacular houses with 田-shaped floor plan at Gangreung have been played important roles in tracing the vernacular living cultures including housing life. But due to the adoption of convenient facilities in vernacular housing lives caused by modernization and urbanization, many changes and transformations have happened at residential space of vernacular houses. This thesis targets to extract basic data to prepare and prevent various problems in process of renovation, extension and function change as installing housing life facilities, and to identify the changes and transformations of them to prepare the proper balances between their original form preservation and residents' convenience living. The results are as follows. The inner wall removal of rooms, the fuel change of cooking and heating, the leveling change of kitchen floor made possible the sedentary lifestyles. And its residential rooms were transformed from two row to one row by inner wall removal, the fuel heating change, the heating method change and the heat insulating materials. The residential extension materials were changed from the traditional materials such as soil, wood, etc to the modern materials such as cement block or brick, sandwich panel, etc. And the modern materials were used and attached to widen residential spaces to the vernacular house because of the easiness of execution. So, it is necessary for 田-shaped floor plan vernacular house owners to distribute printed execution guide book to prevent and minimize the various problems to be shown by extension, renovation and function change.

개구부를 통한 동시다발적인 화재성상에 관한 연구 (A Study on Concurrent Fire Appearance through Openings)

  • 민세홍;이재문
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.90-96
    • /
    • 2012
  • 외장재에 의한 수직화재확산은 확산속도가 구획화재에 비해 매우 빨라 이에 대한 화재의 특성 분석이 요구된다. 본 연구에서는 건물 외부에서 발생한 화재가 연소 확대되면서 수직으로 상승하여 개구부를 통해 유입되는 화재의 성상에 대해서 외장재로 널리 사용되는 심재가 폴리에틸렌인 일반 알루미늄복합패널에 대해 화재시뮬레이션을 적용하여 연구하였다. 그 결과, 수직확산화염은 화재초기에 2층까지 상승하는 데는 약 135초가 걸렸지만 10층까지는 470초, 최고층인 30층까지 상승하는 데는 711초에 도달하는 것으로 분석되어 고층부로 갈수록 난류 및 외장재 설치공간의 연돌효과에 의해서 급격히 확대되는 것을 알 수 있었다. 이러한 연구 결과로 외장재가 설치된 건축물의 화재 시 개구부를 통한 화재는 동시다발적으로 그 건물의 내부에 확대되는 심각성을 확인할 수 있었다.

학교 컴퓨터실의 전기안전에 대한 리스크요소 평가 (Assessment of Risk Component for Electrical Safety of Computer Room in School)

  • 길형준;김동욱;이기연;김향곤;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.440-445
    • /
    • 2007
  • This paper deals with assessment of risk component for electrical safety and investigation on the spot of computer room in elementary middle high school. The investigation was carried out side by side for floor, outlet, panel board, earth leakage circuit breaker at computer room In order to assess electrical safety at computer room, grounding simulator and power quality monitor have been used. Potential rise has been measured and analyzed for ground rod and grounding grid by using the simulator. Phase and neutral-line current have been monitored in real time. As a consequence, it is desirable for us to install conductive tile at floor of computer room Grounding grid had better than ground rod for electrical safety. Neutral-line current was produced by unbalanced phase current.

  • PDF

바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구 (A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 송재엽;안병천;김용기;이태원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

한국형 고속전철 하니콤 바닥구조의 등가평판모델 및 방사소음평가 (The Floor Structure of Korean High Speed Train : Equivalent Plate Model and Acoustic Power Radiation)

  • 장준호;이상윤;홍성철;이우식;박철희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.398-404
    • /
    • 1998
  • The acoustic power reduction methods of the vibrating structures are valid to design the quite structure. To calculate the acoustic power, the dynamic responses have to be determined. It is not easy to analyse the structure composed of the corrugated panels. Because of the structural complexity and the many analysing times. To make up for these defects, the equivalent orthogonal panel is presented. Also the acoustic power prediction method of the vibrating structures is proposed. As examples, the equivalent material properties of the corrugated plates are obtained and the acoustic powers of the floor structure are calculated at several frequency regions for KHST.

  • PDF

방사소음 및 투과소음에 대한 승용차량 대시패널의 설계인자 별 영향도 분석 (Evaluation of Design Variables to Improve Sound Radiation and Transmission Loss Performances of a Dash Panel Component of an Automotive Vehicle)

  • 유지우;채기상;박철민;서진관;이기용
    • 한국소음진동공학회논문집
    • /
    • 제22권1호
    • /
    • pp.22-28
    • /
    • 2012
  • While a dash panel component, close to passengers, plays a very important role to protect heat and noise from a power train, it is also a main path that transfers vibration energy and eventually radiates acoustic noise into the cavity. Therefore, it is important to provide optimal design schemes incorporating sound packages such as a dash isolation pad and a floor carpet, as well as structures. The present study is the extension of the previous investigation how design variables affect sound radiation, which was carried out using the simple plate and framed system. A novel FE-SEA hybrid simulation model is used for this study. The system taken into account is a dash panel component of a sedan vehicle, which includes front pillars, front side members, a dash panel and corresponding sound packages. Design variables such as panel thicknesses and sound packages are investigated how they are related to two main NVH indexes, sound radiation power(i.e. structure-borne) and sound transmission loss(i.e. air borne). In the viewpoint of obtaining better NVH performance, it is shown that these two indexes do not always result in same tendencies of improvement, which suggests that they should be dealt with independently and are also dependent on frequency regions.

역드랍 패널 적용 전이슬래브-기둥 접합부의 비선형 유한요소해석을 통한 2면 전단거동 분석 (Two-way Shear Behavior Analysis of Transfer Slab-Column Connection with Reverse Drop Panel Through Nonlinear FE Analysis)

  • 정성훈;강수민;김승일;이창준
    • 한국전산구조공학회논문집
    • /
    • 제33권2호
    • /
    • pp.103-111
    • /
    • 2020
  • 최근 건축구조물에서 전이슬래브 시스템의 사용이 증가하고 있다. 하지만 과도한 전이슬래브의 두께로 인한 경제적, 시공적인 문제가 많이 발생하고 있다. 따라서, 본 연구에서는 피트층의 설비 공간을 활용하여 전이슬래브의 두께를 절감하기 위하여 역드랍 패널을 적용한 전이슬래브 시스템을 고려하였다. 역드랍 패널을 사용하여 전이슬래브의 2면 전단강도를 증진시킴으로써 전이슬래브의 두께를 줄이고자 하였다. 따라서, 역드랍 패널을 이용한 전이슬래브 시스템의 유효성을 검증하고 전단거동을 조사하기 위하여 다양한 설계변수에 대한 역드랍 패널을 적용한 전이슬래브-기둥 접합부의 전단거동을 기존연구에서 검증된 비선형 FEM 해석방법을 사용하여 분석하였다. 최종적으로 비선형 FEM 해석결과와 기존의 2면 전단강도 평가식으로 예측한 전단강도를 비교·분석하여 기존 평가식의 역드랍 패널을 적용한 전이슬래브-기둥 접합부의 2면 전단강도 평가에 대한 유효성을 검증하였다.

철도차량용 알루미늄 압출재의 투과손실 (Sound Transmission Loss of Aluminium Extruded panels for Railway vehicles)

  • 김석현;박정철;김종년
    • 소음진동
    • /
    • 제10권4호
    • /
    • pp.662-668
    • /
    • 2000
  • Sound transmission characteristics are investigated on the aluminium extruded panels used for railway vehicles. An equivalent orthotropic plate model and mass law are applied to predict the sound transmission loss. An extruded panel specimen used in the floor of railway vehicles is manufactured and is tested to measure sound transmission loss by two reverberant chamber method. Predicted transmission loss I compared with measured values and the effect of local resonance on the transmission characteristics is identified. The results are applied to design the extruded panel having better sound insulation performance.

  • PDF

바닥 난방을 사용하는 주택내 거실 온열 환경의 한일비교 (Comparison of Thermal Environment in Livingroom between Korea and Japan)

  • 이민정;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.47-51
    • /
    • 2003
  • In this paper, we compared the thermal environment in the livingroom with panel heating system of Korea and Japan. The houses are two apartments and two single houses in Korea, and two apartments in Japan. The outdoor temperatures, indoor air temperatures, surface temperatures on floor and humidities were measured. The survey to the residents and recording of operation were also collected. The results were as follows.1. The Korean houses are warmer and drier(approximately 23$^{\circ}$C, 38%) than those of Japan.(approximately 20$^{\circ}$C, 57%). And indoor temperaures of Korean apartment are stabie. 2.The residents in Japan put on and off the switches of the heating system frequently.

  • PDF