The Floor Structure of Korean High Speed Train : Equivalent Plate Model and Acoustic Power Radiation
한국형 고속전철 하니콤 바닥구조의 등가평판모델 및 방사소음평가
Abstract
The acoustic power reduction methods of the vibrating structures are valid to design the quite structure. To calculate the acoustic power, the dynamic responses have to be determined. It is not easy to analyse the structure composed of the corrugated panels. Because of the structural complexity and the many analysing times. To make up for these defects, the equivalent orthogonal panel is presented. Also the acoustic power prediction method of the vibrating structures is proposed. As examples, the equivalent material properties of the corrugated plates are obtained and the acoustic powers of the floor structure are calculated at several frequency regions for KHST.
Keywords