• Title/Summary/Keyword: Floor Device

Search Result 142, Processing Time 0.027 seconds

Falls in the General Hospital Inpatients: Incidence, Associated Factors (일개 종합병원 입원환자의 낙상 실태 및 관련 요인)

  • Yang, Hwa-Mi;Chun, Byung-Chul
    • Quality Improvement in Health Care
    • /
    • v.15 no.2
    • /
    • pp.107-120
    • /
    • 2009
  • Background : To estimate fall incidence rate and associated factors in inpatients from a general hospital. Method : The data were collected from 104 fall incident reports developed by the patient safety committee in a general hospital in Seoul from 01 January 2007 to 31 December 2008. Information included general characteristics of patients, factors related to fall, types, places, circumstances and outcomes of fall. Result : The incidence rate of fall, which was 4.4 per 1,000 total discharged patients and 0.5 per 1,000 patient-days, was much lower than that of several hospitals in the United States. The difference may reflect the different incidence reporting system of each hospital. Fall-prone patients were, in general, $$\geq_-$$65 years of age, had an alert mental status, were ambulatory with some assistance, and were dependent on and ambulatory device. High incidence of falls was associated with patients with circulatory disease. The majority of fall events usually occurred in bed or at the bedside in the patient's room, and occurred more often during the night than during the day or evening. Risk factors of fall were use of drugs (antihypertensive or neuropsychiatric drugs) and environmental factors (e.g., overly high bed height, surrounding objects, inadequate fitness shoes and slippery floor). Physical injury occurred in 43.3% of fall events, which typically required diagnosis of injury and treatment such as suturing. Risk factors for repeated falls were use of a neuropsychiatric drug (odds ratio=13.9) and gait disturbance (odds ratio=91.2). Risk factors for fall-related injury were alert mental status (odds ratio=3.3 times more likely to fall than those who were drowsy or in a stupor) and general weakness(odds ratio=3.3 times more likely to fall than those who were not generally weak). Conclusion : Medical and nursing staff should be aware of the fall risk factors of hospitalized patients and should intensively pursue preventative strategies. Development of fall prevention education based on these results is recommended.

  • PDF

Separation of Human Breast Cancer and Epithelial Cells by Adhesion Difference in a Microfluidic Channel

  • Kwon, Keon-Woo;Choi, Sung-Sik;Kim, Byung-Kyu;Lee, Se-Na;Lee, Sang-Ho;Park, Min-Cheol;Kim, Pil-Nam;Park, Suk-Ho;Kim, Young-Ho;Park, Jun-Gyul;Suh, Kahp-Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.3
    • /
    • pp.140-150
    • /
    • 2007
  • A simple, label-free microfluidic cell purification method is presented for separation of cancer cells by exploiting difference in cell adhesion. To maximize the adhesion difference, three types of polymeric nanostructures (50nm pillars, 50nm perpendicular and 50nm parallel lines with respect to the direction of flow) were fabricated using UV-assisted capillary moulding and included inside a polydimethylsiloxane (PDMS) microfluidic channel bonded onto glass substrate. The adhesion force of human breast epithelial cells (MCF10A) and human breast carcinoma (MCF7) was measured independently by injecting each cell line into the microfluidic device followed by culture for a period of time (e.g., one, two, and three hours). Then, the cells bound to the floor of a microfluidic channel were detached by increasing the flow rate of medium in a stepwise fashion. It was found that the adhesion force of MCF10A was always higher than that of MCF cells regardless of culture time and surface nanotopography at all flow rates, resulting in a label-free detection and separation of cancer cells. For the cell types used in our study, the optimum separation was found for 2 hours culture on 50nm parallel line pattern followed by flow-induced detachment at a flow rate of $300{\mu}l/min$.

Risk Management and Telecommunications Research for customers of the accident location (사고선박의 고객위치파악용 위험관리 통신연구)

  • Kwak, Eun-young;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.331-335
    • /
    • 2016
  • When a boating accident, such as a January number three, the customer's risk management issues emerged. Ships and accident risk in confined spaces such as risk management to locate the customer and dangers of probation is available. In this paper, aboard after consent to obtain information for customers to wrist to customers, webbing or portable device embedded in devices and Wireless sensor information Input was attached, disposable consumer information. Customer on board the ship setting for location analysis and positioning according to information communication protocol, ships, each customer's real-time location information on the screen, 3 the foundation of d customers on the floor Can be designed to inform. Threshold designed to reduce the error of the information to analyze the position in current position and errors. Also, to system attacks would control the situation of accident and emergency jaenanguk server with real-time information transmission of information outside the emergency during a disaster, search and Disaster relief to be possible.

  • PDF

Seismic Response Evaluation of Mid-Story Isolation System According to the Change of Characteristics of the Seismic Isolation Device (면진장치 특성 변화에 따른 중간층 면진시스템의 지진응답 평가)

  • Kim, Hyun-Su;Kim, Su-Geun;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.109-116
    • /
    • 2018
  • As the number of high-rise buildings increases, a mid-story isolation system has been proposed for high-rise buildings. Due to structural problems, an appropriate isolation layer displacement is required for an isolation system. In this study, the mid-story isolation system was designed and the seismic response of the structure was investigated by varying the yield strength and the horizontal stiffness of the seismic isolation system. To do this, a model with an isolation layer at the bottom of $15^{th}$ floor of a 20-story building was used as an example structure. Kobe(1995) and Nihonkai-Chubu(1983) earthquake are used as earthquake excitations. The yield strength and the horizontal stiffness of the seismic isolation system were varied to determine the seismic displacement and the story drift ratio of the structure. Based on the analytical results, as the yield strength and horizontal stiffness increase, the displacement of the isolation layer decreases. The story drift ratio decreases and then increases. The displacement of the isolation layer and the story drift ratio are inversely proportional. Increasing the displacement of the isolation layer to reduce the story drift ratio can cause the structure to become unstable. Therefore, an engineer should choose the appropriate yield strength and horizontal stiffness in consideration of the safety and efficiency of the structure when a mid-story isolation system for a high-rise building is designed.

Design Development of wall mount type air purifier (벽걸이 형식을 도입한 공기청정기 디자인 개발)

  • Han, Il-Woo
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.219-222
    • /
    • 2005
  • This study is for the design developement of wall mount air purification device used for pleasant and clean resident environment. As more people have the high standard of living, they are interested in the air quality of indoor environment, since it is believed its relationship with human health. Now the social demand of air purifier is increasing. Its market is growing and there are various design products in the market. However, dominant current products are floor-based standing type, it needs much spaces to install for the air inhalation and exhaust. Therefore, this product provides the space-saved design. Its concept comes from existing wall mount type air conditioners. The effect of wall decoration is another merit of this proposal. It has an easy filtering change and cleaning system and a simple operation of multiple functions. This product also has the perfect-matched slim design that is consist of natural curves with rectangle for any indoor spaces.

  • PDF

Terra-Scope - a MEMS-based vertical seismic array

  • Glaser, Steven D.;Chen, Min;Oberheim, Thomas E.
    • Smart Structures and Systems
    • /
    • v.2 no.2
    • /
    • pp.115-126
    • /
    • 2006
  • The Terra-Scope system is an affordable 4-D down-hole seismic monitoring system based on independent, microprocessor-controlled sensor Pods. The Pods are nominally 50 mm in diameter, and about 120 mm long. They are expected to cost approximately $6000 each. An internal 16-bit, extremely low power MCU controls all aspects of instrumentation, eight programmable gain amplifiers, and local signal storage. Each Pod measures 3-D acceleration, tilt, azimuth, temperature, and other parametric variables such as pore water pressure and pH. Each Pod communicates over a standard digital bus (RS-485) through a completely web-based GUI interface, and has a power consumption of less than 400 mW. Three-dimensional acceleration is measured by pure digital force-balance MEMS-based accelerometers. These accelerometers have a dynamic range of more than 115 dB and a frequency response from DC to 1000 Hz with a noise floor of less than $30ng_{rms}/{\surd}Hz$. Accelerations above 0.2 g are measured by a second set of MEMS-based accelerometers, giving a full 160 dB dynamic range. This paper describes the system design and the cooperative shared-time scheduler implemented for this project. Restraints accounted for include multiple data streams, integration of multiple free agents, interaction with the asynchronous world, and hardened time stamping of accelerometer data. The prototype of the device is currently undergoing evaluation. The first array will be installed in the spring of 2006.

Emission of Airbone Pollutants from Traditional Korean Fireplace (아궁이 사용에 의한 대기오염물질의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee
    • Journal of Climate Change Research
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • Emission from the traditional Korean fireplace, or the under-floor heating and cooking device, can contribute significantly to airborne pollutants inventories. This study has systematically measured emissions of airborne pollutants from the fireplace when used different fuels such as firewood, agricultural crop residuals, household wastes. The results show that emission factors of airborne pollutants through the primary combustion of firewood were 3.22 g/kg for TSP, 2.93 g/kg for $PM_{10}$, 2.65 g/kg for $PM_{2.5}$, 174.19 g/kg for CO, 7.77 g/kg for NO, 0.15 g/kg for $SO_2$, 40.53 g/kg for TVOC and 0.03 g/kg for $NH_3$; from burning of agricultural crop residues, 2.85 g/kg for TSP, 1.38 g/kg for $PM_{10}$, 1.14 g/kg for $PM_{2.5}$, 126.47 g/kg for CO, 12.60 g/kg for NO, 0.20 g/kg for $SO_2$, 33.73 g/kg for TVOC and 0.02 g/kg for $NH_3$; and for household wastes, 10.52 g/kg for TSP, 8.52 g/kg for $PM_{10}$, 6.23 g/kg for $PM_{2.5}$, 72.86 g/kg for CO, 11.73 g/kg for NO, 0.20 g/kg for $SO_2$, 47.10 g/kg for TVOC and 0.20 g/kg for $NH_3$.

Seismic Retrofitting Effects of General Hospital Using Self-Centering Energy Dissipative Bracing System (자기복구형 에너지소산 가새시스템을 적용한 종합병원의 내진보강효과)

  • Kim, Taewan;Chu, Yurim;Bhandari, Diwas
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.159-167
    • /
    • 2019
  • 2016 Gyeongju and 2017 Pohang earthquakes led Koreans to acknowledge that the Korean peninsula is not an earthquake-free zone anymore. Among various buildings crucial to after-shock recovery, general hospital buildings, especially existing old ones, are very significant so seismic retrofitting of those must be an important issue. Self-centering energy dissipative(SCED) brace is one of retrofitting methods, which consists of tendon with restoring force and friction device capable of dissipating seismic energy. The strength of the SCED brace is that the tendon forces a structure to go back to the original position, which means residual drift can be negligible. The residual drift is a very important parameter to determine usableness of general hospitals after shock. To the contrary, buckling-restrained braces(BRB) are also a very effective way to retrofit because they can resist both compressive and tensile, but residual drift may exist when the steel core yields. On this background, the seismic retrofitting effect of general hospitals reinforced with SCED braces was investigated and compared to that of the BRD in this study. As a result, although the floor acceleration cannot be reduced, the story drift and residual drift, and the shear demand of walls significantly decreased. Consequently, seismic retrofitting by SCED braces are very effective for domestic low-rise general hospitals.

A Study on Equipment and Space Composition of Heavy Ion Therapy Center (중입자치료센터의 장비 및 공간 구성에 관한 연구)

  • Hong, chang pyo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.4
    • /
    • pp.7-14
    • /
    • 2020
  • Purpose: The purpose of this study is to provide basic information for the establishment of a Heavy Ion Therapy center by analyzing the cases of Heavy Ion Therapy devices, introducing the equipment and space composition of Heavy Ion Therapy equipments. Methods: This study is carried out by study the Heavy Ion Therapy, by figure out status of the installation of treatment centers around the world and by analyze the composition of Heavy Ion Therapy equipments and spaces through case studies. Results: The results of this study, which investigated the treatment of Heavy Ion Therapy and analyzed the plans of the five Heavy Ion Therapy centers, are summarized as follows. 1) Heavy Ion equipment requires a significant floor area. Vertical as well, many cross-sectional areas need to be secured for the construction of a delivery system. The Heavy Ion Therapy device should be built as a shielded wall because of the radiation leaking. Therefore, it is necessary to consist of a independent treatment center. 2) The size of Heavy Ion devices is getting smaller. Linac can be put into syncrotron. and the size of syncrotron, delivery system, and rotating-gantry is getting smaller. 3) Japan is often installed for treatment, and control rooms are integrated, while Europe has secured research space and each control room is separated. Implications: People are not familiar with the Heavy Ion Therapy. And the effectiveness of the treatment is not well promoted yet. Hopefully, more attention will be paid to the research involved in the Heavy Ion Therapy.

Analysis of Damping Performance of Hysteretic Dampers of Buckling restrained Braced Type According to eccentricity of school buildings with Torsional irregularities (비틀림 비정형을 가지는 학교건물의 편심율에 따른 좌굴방지가새형 이력댐퍼의 제진성능분석)

  • Kim, Yu-Seong;Lee, Joon-Ho;Kim, Gee-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2023
  • In the case of a school building, even though it is a regular structure in terms of plan shape, if the masonry infill wall acts as a lateral load resisting element, it can be determined as a torsionally irregular building. As a result, the strength and ductility of the structure are reduced, which may cause additional earthquake damage to the structure. Therefore, in this study, a structure similar to a school building with torsional irregularity was selected as an example structure and the damping performance of the PC-BRB was analyzed by adjusting the eccentricity according to the amount of masonry infilled wall. As a result of nonlinear dynamic analysis after seismic reinforcement, the torsional irregularity of each floor was reduced compared to before reinforcement, and the beams and column members of the collapse level satisfied the performance level due to the reduction of shear force and the reinforcement of stiffness. The energy dissipation of PC-BRB was similar in the REC-10 ~ REC-20 analytical models with an eccentricity of 20% or less. REC-25 with an eccentricity of 25% was the largest, and it is judged that it is effective to combine and apply PC-BRB when it has an eccentricity of 25% or more to control the torsional behavior.