• Title/Summary/Keyword: Flicker System

Search Result 139, Processing Time 0.023 seconds

A Study on the Fliker Effect of SVC in Electric Arc Furnace Loads (전기로 부하에서 SVC의 플리커 효과에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Il-Moo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.48-53
    • /
    • 2006
  • An electric arc furnace being used in the steel industry is a time-varying non-linear load causing voltage fluctuations to the power system. Flicker can be defined as the effect produced on the human visual perception by a changing emission of light lamps subjected to magnitude fluctuations of their supply voltage. The level of flicker depends on the amplitude, frequency and duration of the voltage fluctuations. In this paper, the voltage fluctuation problem in an 154[kV] system due to the electric arc furnace loads is investigated and the analysis results of the static var compensator application for the voltage flicker mitigation are presented and evaluated by the IEC 61000-3-7.

Large viewing angle walk through type display using smoke screen

  • Sato, Koki;Takano, Kunihiko;Ohki, Makoto
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.790-793
    • /
    • 2009
  • In the case of projection type display, it needs to use the screen in order to project the image clearly and wide viewing angle. We have been developing the step in type display system using the smoke screen. However, the image with smoke screen was flickered by gravity and air flow. Then we considered to reduce the flicker of the image and we found that flicker can be reduced and viewing angle becomes more large. This time we report the large viewing angle step in type display system using screen made up with very small particle size smoke and flow controlled nozzle. Hence, at first we considered the most suitable particle for the screen and then the shape of screen and then we constructed the array of flow controlled smoke screen. By the results of experiment we could get considerably high contrast flicker-less image and get the viewing angle more than $60^{\circ}$ by this flow controlled nozzle attached new type smoke screen and make clear the efficiency of this method.

  • PDF

The Flicker Control by Feed-forward for Stabilization of CVCF Inverter (철도차량용 보조전원장치의 전향제어를 이용한 Flicker 제어)

  • 박채운;신형진;조국춘;원충연
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.267-272
    • /
    • 1999
  • The auxiliary power supply system fur passenger service of railway car has been developed from MA(Motor-Alternator) to CVCF Inverter (Static Inverter). Generally, a customer wants to apply tile new control method and device for auxiliary power supply of railcar However, if the auxiliary power supply is supplied to extended existing line, the maintenance cost of the old system is less expensive than new developed system, so, the customer specifies that the auxiliary power supply has compatibility with existing one completely. At that time, the hardware is nearly same as existing system except small changes of accessories for better performance. This paper describes the flicker control using feed-forward method of auxiliary power supply system for new 50 electric railcars, which are delivered to Korean National Railroad (KNR) Kwa-chon Line. The existing power supply system has damping resistor box to stabilize the DC input (1.5 ㎸). At this time, for better system efficiency the new system has not include resistor box but new control method including feed-forward control is applied. This control algorithm realizes the better stabilization of input power compared to the result of the existing system, which includes resistor box

  • PDF

Dimming Control in Visible Light Communication Using Subcarrier Modulation of Manchester Code (맨체스터 코드의 부반송파 변조를 이용한 가시광통신의 조명제어)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.191-197
    • /
    • 2019
  • In this study, we propose a dimming control method for a visible light communication (VLC) system, in which the subcarrier on-off keying (OOK) modulation of Manchester code is used for data transmission. In the VLC transmitter, non-return-to-zero (NRZ) code data is transformed to Manchester code, which is OOK modulated with a subcarrier. Manchester code is used for flicker-free lighting; the duty factor is changed for dimming control, and the subcarrier is used for preventing the adjacent noise light interference. In the experiments, the dimming control was carried out from about 8%-92% of the continuous wave (CW) LED light. This configuration is simple and effective in constructing a VLC system for indoor wireless sensor networks with flicker-free illumination and dimming control capability without adjacent noise light interference.

Adaptive-learning Code Allocation Technique for Improving Dimming Level and Reducing Flicker in Visible Light Communication (가시광통신에서 Dimming Level 향상 및 Flicker 감소를 위한 적응-학습 코드할당 기법)

  • Lee, Kyu-Jin;Han, Doo-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.2
    • /
    • pp.30-36
    • /
    • 2022
  • In this paper, when the lighting and communication functions of the visible light communication system are used at the same time, we propose a technique to reduce the dimming level and flicker of the lighting. Visible light communication must satisfy both communication and lighting performance. However, the existing data code method results in reducing the brightness of the entire lighting. This causes deterioration of lighting performance and flicker phenomenon. To solve this problem, in this paper, we propose an adaptive learning code allocation technique that allocates binary codes to transmitted characters and optimizes and matches the binary codes allocated according to the frequency of occurrence of alphabets in character strings. Through this, we studied a technique that can faithfully play the role of lighting as well as communication function by allocating codes so that the 'OFF' pattern does not occur continuously while maintaining the maximum dimming level of each character string. As a result of the performance evaluation, the frequency of occurrence of '1' increased significantly without significantly affecting the overall communication performance, and on the contrary, the frequency of consecutive '0' decreased, indicating that the lighting performance of the system was greatly improved.

Development of a New Automatic Image Quality Optimization System for Mobile TFT-LCD Applications (모바일 TFT-LCD 응용을 위한 새로운 형태의 자동화질 최적화 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.17-28
    • /
    • 2010
  • This paper presents a new automatic TFT-LCD image quality optimization system using DSP for the first time. Since conventional manual method depends on experiences of LCD module developers, it is highly labor-intensive and requires several correction steps providing large gamma correction error. The proposed system optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. It contains module-under-test (MUT, TFT-LCD module), PC installed with program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. We have developed a new algorithm using 6-point programmable matching technique with reference gamma curve and applying automatic power setting sequence. Developed algorithm and program are generally applicable for most of the TFT-LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0, and reduce flicker level. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than conventional manual method. We believe that the proposed system is very useful to provide high-quality TFT-LCD and to improve developing process using optimized gamma-curve setting and automatic power setting.

Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System (전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석)

  • Oh, Kwan-Il;Jeon, Young-Soo;Park, Sang-Tae;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

Signal Synchronization Using a Flicker Reduction and Denoising Algorithm for Video-Signal Optical Interconnect

  • Sangirov, Jamshid;Ukaegbu, Ikechi Augustine;Lee, Tae-Woo;Cho, Mu-Hee;Park, Hyo-Hoon
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.122-125
    • /
    • 2012
  • A video signal through a high-density optical link has been demonstrated to show the reliability of optical link for high-data-rate transmission. To reduce optical point-to-point links, an electrical link has been utilized for control and clock signaling. The latency and flicker with background noise occurred during the transferring of data across the optical link due to electrical-to-optical with optical-to-electrical conversions. The proposed synchronization technology combined with a flicker and denoising algorithm has given good results and can be applied in high-definition serial data interface (HD-SDI), ultra-HD-SDI, and HD multimedia interface transmission system applications.

A Study on the Fatique of School Pupils, on the Basis of the Fusion Frequency of Flicker (Flicker치에 의한 학생 피로도에 관한 연구)

  • 이병근;송종대
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.8
    • /
    • pp.35-40
    • /
    • 1983
  • The fusion frequency of flicker (F.F.F.) of 40 pupils were examined every day repeatedly, from Monday to Saturday. (1) The individual Variations of F.F.F. were statistically highly significant, p < 0.01 (2) Day to day Variations of F.F.F. were statistically highly significant, p < 0.01 (3) The interaction between age and weekly change was highly significant, p < 0.01 (4) The interaction between sex difference and weekly change was also significant, p < 0.01 (5) The interaction among age, sex and weekly change was significant at 1% level of significance.

  • PDF

Study about varying aspects of flicker indices by load fluctuating in electric railway system (전기철도환경하에서 부하변동에 따른 플리커지수의 변화양상에 대한 연구)

  • Lee Kang-Won;Kim Myung-Yong;Baik Kwang-Sun;Kim Won-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.655-659
    • /
    • 2005
  • The environment. of electric railway has, included both fast and slow load variation, which may occur in the office or maintenance factory or running electric train. This paper investigated flicker indices according to voltage fluctuations on three different situations; The base office in new subway in the daytime and night time, inside of electric train running in conventional subway. And also the variations of harmonic frequencies(2nd, 3rd, 5th) with rime were measured at the same time. Flicker index is a good tool for evaluating the voltage fluctuation quantitatively and show some relationship with even harmonic frequencies produced by the voltage fluctuation when the electric train is running on the railway.

  • PDF