• Title/Summary/Keyword: Fixture level

Search Result 76, Processing Time 0.026 seconds

A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise (차량용 에어컨 부밍 소음의 전달 특성에 관한 연구)

  • Lim, Seung Taek;Joo, Kyung Hoon;Ahn, Hew Nam;Park, Young Duk;Kang, Yean Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

A Study on the Development of Database for Lighting Design System (조명 설계 시스템을 위한 데이터베이스 개발에 관한 연구)

  • 조성오
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.196-203
    • /
    • 2004
  • In The Lighting design is important to acknowledge appearance space. Development of artificial light makes a extension to life space in the Modern life. With the rapid development of efficient light sources, have lighting design acquired the tools that allow artificial lighting to be produced with adequate illuminance levels. However, by the task of defining the objectives and methods behind discipline, of deciding on the criteria by which the artificial lighting that is now provide many available data to be anpaied. The main concern is which illuminace levels and types of lighting will ensure optimum visual performance, high productive and safety at design which are affordable. This study is support to standard design process with material reflection rate, installing the lighting fixture, task illuminance level and automatic arithmetic calculation during the lighting design. Lighting Design database can check and support other final lighting level. A quantitative light that is primarily oriented toward providing a recommended illuminance level, the criterion of develop a concept that goes beyond the requirements that would ensure productivity and safety to meet the needs of the architecture and interior space. illuminance level is compose to space task and space code according to KS A 3011. To be able to design the visual effect of an environment the central reference quantity has to provided the Database.

Vibration Analysis for Car Installed Transverse Engine Through Experimetal Method (실험적 방법을 통한 횡 탑재 엔진 차량에 대한 진동 해석)

  • 양성모;김남응;김중희
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.769-777
    • /
    • 1999
  • Research on vibration of a vehicle with a transversely mounted 4-cylinder engine was performed using a vector synthesis method, Data of the engine vibration for the vector synthesis method was obtained experimentally and the data was ODS-fitted to calculate vibration level on any engine location assuming that the engine is rigid body in the frequency range of interest. In order to derive the excitation force on the vehicle body, the displacements were converted from the acceleration of engine. The transfer functions from engine mounts to toe pan on the floor were obtained experimentally. The vibration level on the toe pan was predicted by multiplying the excitation force by the transfer function. The predicted vibration level was compared with experimental data and the result was reasonable. Using the developed method, analysis was made for the effect of body fixture conditions of the vehicle when testing the engine vibration and for the effect of the transfer functions when the engine is installed or when the engine is removed. Finally the degree of contribution for 12 transfer paths was calculated.

  • PDF

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

  • Yoon, Ki-Joon;Park, Young-Bum;Choi, Hyunmin;Cho, Youngsung;Lee, Jae-Hoon;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.465-471
    • /
    • 2016
  • PURPOSE. The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of $1.0{\times}10^6$cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level (치조골 높이가 다른 임프란트 주위 지지골 응력분석)

  • Boo, Soo-Boong;Jeung, Jei-Ok;Lee, Seung-Hoon;Kim, Chang-Hyun;Lee, Seung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

Development and Feasible Study of Train to Pedestrian Protection Airbag (철도차량 접촉사고자 보호 에어백 개발연구)

  • Yoo, Wan-Dong;Ham, Joung-Sik;Cho, Kyue-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.82-91
    • /
    • 2012
  • This paper deals with the development and feasible study of the train to pedestrian protection airbag. The concept of the airbag system is to protect the pedestrian like as workers on railroad. The airbag system includes cushions, gas generators, a housing, sliding fixture, anti-bouncing airbag, and a leg protection bumper. Those things were designed and fabricated. The performance of the airbag system was evaluated in the sense of the static deployment test, drop test, dynamic motion test and field(train level) test. The deployment logic, TTF(Time to fire), and the inner pressure of the cushion were also investigated for the airbag.

A Dual Vacuum Wafer Prealigner and a Multiple Level Structure (2단 진공 웨이퍼 정렬장치 및 다층 구조 설계)

  • Kim, H.T.;Choi, M.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.3
    • /
    • pp.14-20
    • /
    • 2011
  • This study aims at aligning multiple wafers to reduce wafer handling time in wafer processes. We designed a multilevel structure for a prealigner which can handle multiple wafer simultaneously in a system. The system consists of gripping parts, kinematic parts, vacuum chucks, pneumatic units, hall sensors and a DSP controller. Aligning procedure has two steps: mechanical gripping and notch finding. In the first step, a wafer is aligned in XY directions using 4-point mechanical contact. The rotational error can be found by detecting a signal in a notch using hall sensors. A dual prealigner was designed for 300mm wafers and constructed for a performance test. The accuracy was monitored by checking the movement of a notch in a machine vision. The result shows that the dual prealigner has enough performance as commercial products.

A Study on the Freeform Surface Generation Using Parametric Method (파라메트릭기법을 이용한 3차원 자유곡면 생성에 관한 연구)

  • 김태규;변문현
    • Korean Journal of Computational Design and Engineering
    • /
    • v.3 no.4
    • /
    • pp.293-303
    • /
    • 1998
  • The objective of this study is to develop a PC level freeform surface modeling system which explicitly represents information of part geometry. Surface modeler uses nonuniform rational B-spline (NURBS) function with nonuniform knot vector for the flexible modeling work. The results of this study are as follows. 1) By implementation surface modeler through applying representation scheme proposed to represent free-form surface explicity, the technical foundation to develop free-from surface modeling system using parametric method. 2) Besides the role to model geometric shape of a surface, geometric modeler is developed to model arbitrary geometric shape. By doing this, the availability of the modeling system is improved. Geometric modeler can be utilized application fields such as collision test of tool and fixture, and tool path generation for NC machine tool.

  • PDF