Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level

치조골 높이가 다른 임프란트 주위 지지골 응력분석

  • Boo, Soo-Boong (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Jeung, Jei-Ok (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Lee, Seung-Hoon (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Kim, Chang-Hyun (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Lee, Seung-Ho (Department of Prosthodontics, College of Dentistry, Chosun University)
  • 부수붕 (조선대학교 치과대학 보철학교실) ;
  • 정제옥 (조선대학교 치과대학 보철학교실) ;
  • 이승훈 (조선대학교 치과대학 보철학교실) ;
  • 김창현 (조선대학교 치과대학 보철학교실) ;
  • 이승호 (조선대학교 치과대학 보철학교실)
  • Published : 2007.03.30

Abstract

The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

Keywords

References

  1. Mish, CE.. 'Contemporary Implant Dentistry. St Louis.' Mosby 290-300, 1993
  2. Tesk, J.A. Widera, O.. 'Stress distribution in bone arising from loading on endoosteal dental implants.' J Biomed Mater Res Symp. 251-261, 1973
  3. Weinstein, AM. Klawitter, JJ. Anand, SC. Schuessler, R.. 'Stress analysis of porous rooted dental implants.' J Dent Res 55:772-777, 1976 https://doi.org/10.1177/00220345760550051001
  4. 김민호 . 박영록 . 계기성. '임플란트 매식시 수직골 높이에 따른 응력분석' 대한턱관절기능교합학회 제18권(4) : 302 -311, 2002
  5. 배숙진 . 정재헌 . 정승미. '하중의 위치 및 경사에 따른 임프란트 보철의 유한요소법적 응력 분석' 대한턱관절기능교합학회 제19권(4) : 257-268, 2002
  6. 이태엽 . 강동완. '임플란트 고정체의 매식경사에 따른 응력 분석' 대한치과턱관절기능교합학회 제18권(4) : 321-329, 2002
  7. 허성주 . 한종현 . 정종평. '골유착성 임프랜트 고 정체의 설계변화에 따른 응력분포에 관한 삼차원 유한요소 분석적 연구' 대한치과보철학회지, 35: 609-619, 1997
  8. Rho, JY. Ashman, RE. Turner, CH.. 'Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements.' J Biomech 26:111-119, 1993 https://doi.org/10.1016/0021-9290(93)90042-D
  9. Gratton, DG. Aquilino, SA. Stanford, CM.. 'Micromotion and dynamic fatigue properties of the dental-implant interface.' J Prosthet Dent 85:47-52, 2001 https://doi.org/10.1067/mpr.2001.112796
  10. Hermann, JS. Schoolfield, JD. Schenk, RK. Buser, D. Cochran, DL.. 'Influence plants. A histometric evaluation of unloaded non-submerged implants in the canine mandible.' J Periodontol 72:1372-1383, 2001 https://doi.org/10.1902/jop.2001.72.10.1372
  11. Meijer,HJ., Kuiper,J.H., Starmans,F.J., Bosman,F.. 'Stress distribution around dental implants; Influence of superstructure, length of implants, and height of mandible.' J. Prosthet Dent., 68: 96-102, 1992 https://doi.org/10.1016/0022-3913(92)90293-J
  12. Rieger, MR. Mayberry, M. Brose, MO.. 'Finite element analysis of six endosseous implants.' J Prosthet Dent 63:671-676, 1990 https://doi.org/10.1016/0022-3913(90)90325-7
  13. Geng, JP. Tan, KB. Liu, GR.. 'Application of finite element analysis in implant dentistry: a review of the literature.' J Prosthet Dent 85:585-598, 2001 https://doi.org/10.1067/mpr.2001.115251
  14. Geng, JP. Tan, K.B.C. Liu, GR.. 'Finite element analysis of an osseointegrated stepped screw dental implant.' J Oral Implantology 30:4, 223-233, 2004 https://doi.org/10.1563/0654.1
  15. Holmgren, EP. Seckinger, RJ. Kilgren, LM. Mante, F.. 'Evaluation of parameters of osseointegrated dental implants using finite element analysis-a Two-dimensional comparative study examining the effects of implant diameter, implant shape, ant load direction.' J Oral Implantol 24:80-88, 1998 https://doi.org/10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO;2
  16. Van Oosterwyck, H. Duyck, F. Vander, S. et al.. 'The influence of bone mechanical properties and implant fixation upon bone loading around oral implants.' Clin Oral Implant Res 9:407-418, 1998. https://doi.org/10.1034/j.1600-0501.1996.090606.x
  17. Jaffin, RA. Bermen, CL.. 'The excessive loss of Braenemark fixtures in type IV bone; a 5-year analysis.' J Periodontol 62:2-4, 1991 https://doi.org/10.1902/jop.1991.62.1.2
  18. Rangert, B. Krogh, PH. Langer, B. Van Roekel, N.. 'Bending overload and implant fracture: a retrospective clinical analysis.' Int J Oral Implants 10:326-334, 1995
  19. Bmnski, JB.. 'Biomcchanical factors affecting the bone-dental implant interface.' Clin Mater 10:153-201, 1992 https://doi.org/10.1016/0267-6605(92)90049-Y
  20. Jones, PA. Wilson, HF. Osborne, J.. 'Impact properties of dental materials.' Br Dent J 129:565-570, 1970 https://doi.org/10.1038/sj.bdj.4802614
  21. Mojdehi, M. Foster, MK. Buschang, PH.. 'Throckmor foods [abstract].' J Dent Res 76:244, 1997
  22. Pilliar, RM. Deporter, DA. Watson, PA. Valiquette, N.. 'Dental implant design-effect on bone remodeling.' J Biomed Mater Res 25:467-483, 1991 https://doi.org/10.1002/jbm.820250405
  23. Meijer, HJ, Starmans, FJ. Steen, WH. Bosman, F.. 'A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible.' Arch Oral Biol 38:491-496, 1993 https://doi.org/10.1016/0003-9969(93)90185-O
  24. Rieger, M.R. Adams, W.K. Kinzel, G.L. Brose, M.O.. 'Finite element analysis of bone-adapted and bone-bonded endosseous implant.' J Prosthet Dent. 436-440, 1989
  25. Barbier, L. Vander Sloten, J. Krzesinski, G. Schepers, E. Van der Perre, G.. 'Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog.' J Oral Rehabil 25:847-858, 1998 https://doi.org/10.1046/j.1365-2842.1998.00318.x
  26. Rieger, MR. Adams, WK. Kinzel, GL. Brose, MO.. 'Alternative materials for three endosseous implants.' J Prosthet Dent, 61:717-722, 1989 https://doi.org/10.1016/S0022-3913(89)80049-6
  27. Clelland, NL. Ismail, YH. Zaki, HS. Pipko, D.. 'Three-dimensional finite element stress analysis in and around the Screw-Vent implant.' Int J Oral Maxillofac Implants 6:391-398, 1991
  28. Hansson, S.. 'The implant neck: sMedth or provided with retention elements A biomechnical approach.' Cli Oral Implant Res., 10:394-405, 1999 https://doi.org/10.1034/j.1600-0501.1999.100506.x
  29. Chun, HJ. Cheong, SY. Han, JH. Chung, JP. Rhyu, IC. et al.. 'Evaluation of design parameter of osseointegrated dental implants using finite element analysis.' J Oral Rehab. 29:565-574, 2002 https://doi.org/10.1046/j.1365-2842.2002.00891.x
  30. French, AA. Bowles, CQ. Parham, PL. Eick, JD. Killoy, WJ. Cobb, CM.. 'Comparison of peri-implant stresses transmitted by four commercially available osseointegrated implants.' Int J Periodont Rest Dent 9:221-230, 1989
  31. Patra, AK. DePaolo, JM. D'Souza, KS. DeTolla, D. Meenaghan, MA.. 'Guidelines for analysis and redesign of dental implants.' Implant Dent 7:355-368, 1998 https://doi.org/10.1097/00008505-199804000-00007
  32. Clift, SE. Fisher, J. Watson, CJ.. 'Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus.' Proc Inst Mech Eng [H] 206:233-241, 1992
  33. Gibbs, CH. Mahan, PE. Lundeen, HC. et al.. 'Occlusal forces during chewing & mdash influence of biting strength and food consistency.' J Prosthet Dent 46:561-567, 1981 https://doi.org/10.1016/0022-3913(81)90247-X