• Title/Summary/Keyword: Fire-retardant

Search Result 266, Processing Time 0.023 seconds

Flame Retardancy of Plywood Treated with Various Water Glass Concentration and Additives (물유리의 농도와 첨가제 종류에 따른 방염제의 성능)

  • PARK, Sohyun;HAN, Yeonjung;SON, Dong Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.1
    • /
    • pp.44-56
    • /
    • 2021
  • The carbonized length and area of plywood by the various spreading concentration of water glass and the type of additives were measured in accordance with the 45° MecKel's burner method of the fire protection performance standard of the Korean National Fire Agency. As a result of treating water glass with a concentration of 20 to 50 % on plywood, the flame retardancy tended to increase in proportion to the concentration of water glass. However, the optimum concentration of water glass was determined to be 30 % due to the efflorescence and sticky on the surface of plywood treated with high-concentration water glass of more than 30 %. As a result of the experiment by adding different proportions of additives to the water glass with concentration of 30 %, the standard of flame performance standard was satisfied under the conditions with the addition of 15% potassium hydroxide and 1-10% aluminum hydroxide, respectively. On the other hand, there were no significant difference in the flame retardancy by adding magnesium sulfate. These results about the flame retardancy of plywood by water glass and additives were expected to be basic data for improving flame-retardant treated wood.

Content of plasticizers and heavy metals in the selling PVC wallpapers (시판 PVC 벽지 중 가소제 및 중금속 함량)

  • Lee, Cheol-Won;Jung, Tak-Kyo;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • Plasticizer and heavy metals in domestic PVC wallpaper manufactured in Korea after 2005 were analyzed to identify the contained quantity in comparison with the 2002 manufactured PVC wallpapers. Plasticizer of wallpapers was analyzed by the method KSM1991 which uses soxhlet extraction with n-hexane and GC/FID. Heavy metals were pre-treated with 0.07 mol/L hydrochloric acid (HCl) and analyzed by ICP/OES according to the EN 71-part 3 method. DEHP, DINP, DEP, acetyl tributyl citrate were identified from wallpaper. Contents of DEHP, DINP were 0.2~11.3%, 17.9~27.8% respectively in 6 wallpapers, DEP and acetyl tributyl citrate were 1.5%, 8.9% respectively in one wallpaper. Plasticizers have changed from DEHP that has possibility of hazards to DINP, DEP and acetyl tributyl citrate as compared with 2002. Heavy metals were detected under guide line from all of the wallpapers except fire-retardant wallpaper contain antimony. While PVC wallpaper was improved by use of various plasticizer, functional wallpapers such as fire-resistant wallpaper contain high antimony in this study.

Flame Retardancy of Veneers Treated by Ammonium Salts (암모늄염으로 처리한 베니어의 난연성)

  • Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.18 no.3
    • /
    • pp.251-254
    • /
    • 2007
  • Veneer plate was painted by the treatment with ammonium salts such as ammonium chloride (AMCR), ammonium sulfate (AMSF), monoammonium phosphate (MAPP), and diammonium phosphate (DAPP) at room temperature. The flame retardancy of painted veneer plate was investigated. The painted veneer plate shows an increased $CO/CO_2$ over virgin veneer and it was supposed to affect the toxicity to different extents. But when the ammonium salts were used as the retardant for veneer, the flame retardancy was improved due to the painted ammonium salts in the veneers. Also, the veneer plates with ammonium sulfate and ammonium chloride showed both the lower total smoke release (TSR) and lower total smoke production (TSP) than that of virgin veneer.

Melting Characteristics of Asbestos Cement Slate on Basicity Control (염기도 조절에 의한 석면슬레이트 용융특성)

  • Yun, Jinhan;Keel, Sangin;Min, Taijin;Lee, Chungkyu;Jang, Duhun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.159.2-159.2
    • /
    • 2010
  • Asbestos is the collective name for a group of naturally occurring minerals in their fibrous form and hydrous silicates of magnesium and a mineral fiber that has been used commonly in a variety of building construction materials for insulation and as a fire-retardant. Asbestos has been used for a wide range of manufactured goods, because of its fiber strength and heat resistant properties. Nevertheless harmful of asbestos is quite serious. Exposure to airborne friable asbestos may result in a potential health risk because persons breathing the air may breathe in asbestos fibers. Continued exposure can increase the amount of fibers that remain in the lung. Fibers embedded in lung tissue over time may cause serious lung diseases including asbestosis, lung cancer. In this paper, we carried out as fundamental study for dispose of asbestos cement slate safely and perfectly. Melting Temperature of asbestos need to more than $1,520^{\circ}C$ and specially asbestos cement slate need more energy than that of pure asbestos. We need to decrease melting temperature of asbestos cement slate for economical efficiency. To the purpose, glass and bottom ash were chosen as additives for basicity control. we analyzed about properties of asbestos cements slate, melting characteristics on the additives ratio and temperature. We confirmed about harmlessness of melting slag through analysis of scanning electron microscope(SEM) and x-ray diffractometer(XRD).

  • PDF

Properties and Thermal Characteristics of Phenol Foam for Heat Insulating Materials (단열재용 페놀폼의 물성과 열적특성)

  • Kim, Dong-Kwon;Lee, Soo-Bok
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.357-360
    • /
    • 2006
  • In this study, we studied the physical properties and application of PF foam as heat insulating materials. In the experimental results, the density of PF foam showed $0.030g/cm^3$ and the thermal conductivity showed $0.026kcal/m.h.^{\circ}C$. Also, thermal resistance of the prepared PF foam was volatilized about 71.7 wt% when the temperature was $500^{\circ}C$ (1 h). And the chemical structure of PF foam have a closed cell type in the important properties as heat insulating materials. Therefore, it was confirmed that the prepared PF foam had excellent performance as heat insulating materials.

Housing Market and Opportunities for Wood Frame Housing in Korea (우리나라의 주택시장구조(住宅市長構造)와 목조주택개발(木造住宅開發))

  • Park, Moon-Jae;Kim, Wae-Jung;Han, Kap-Joon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.45-52
    • /
    • 1991
  • To investigate opportunities for wood frame housing and to activate wood frame house construction, trends of construction activities. preference about housing, and building codes related to wood frame housing were discussed. And two models of wood frame house were developed and construction cost was analyzed to compare with comparative masonry houses. The results obtained were as follows: 1. While 77.8% of people prefer single-family houses, majority of people(74.9%), ironically, possess multi-family houses such as apartments Wood work cost was ratio of 4% of total building cost. while wood material cost accounted merely for 11 % out of total building material cost. 2. Building code was not major barrier to residential house at height under 13m. The building code regulated major structural member and family boder wall of multi-family house to be built with fire retardant material. 3. The proper wood frame house was analyzed of town house or villa type locating in suburban of big city with hot ondol system for the upper middle class. 4 There was no difference in construction cost between western style wood frame house and comparable masonry house, but construction cost for Korean style wood frame house is 27% higher than that of comparable masonry house. It was necessary to reduce materials and cost down by prefabrication technique for both style of wood frame house.

  • PDF

A Study on the Effect of Expandable Graphite and Metal Hydroxides on the Properties of Wood Plastic Composites (WPCs) (팽창성 흑연과 금속수산화물이 목재·플라스틱 복합재의 특성에 미치는 영향에 관한 연구)

  • Kim, Seungkyun;Lee, Danbee;Lee, Sun-Young;Chun, Sang-Jin;Kim, Birm-June
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.4
    • /
    • pp.392-398
    • /
    • 2016
  • Wood-plastic composites (WPCs) composed of mainly wood flour and thermoplastics have attracted considerable attentions due to advantages of cost effectiveness, high durability, and microbial resistance. However, relatively poor fire resistance of WPCs from low thermal stability of wood and plastics prevents further uses. This study investigated the effect of expandable graphite (EG) and aluminium hydroxide (AH)/magnesium hydroxide (MH) on the properties of WPCs. The combined incorporation of both EG and metal hydroxide (i.e., AH or MH) into formulations leads to higher flexural modulus of filled composites compared to neat PP and WPC. In thermal properties, EG played an important role in improving thermal stability of filled composites by suppressing thermal decompositions of wood and PP. Moreover, EG showed better water absorption features. From this research, it can be said that EG and metal hydroxides have potentials as effective reinforcement, flame retardant, and moisture barrier.

Effect of Cyclic Exposure on the Mechanical Properties of Fire Retardant Treated Plywood (순환적 폭로가 내화처리 합판의 기계적 성질에 미치는 영향)

  • Kim, Jong-Man;Levan, Susan L.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.31-38
    • /
    • 1990
  • 합판(合板)에 내화약제(耐火藥劑) 가압법(加壓法)에 의하여 약 1,588kg/$(30cm)^3$(3.5lbs/$ft^3$)을 주입시켜 내화합판(耐火合板)을 제조(製造)한 후(後), 이들 합판(合板)의 합수율(含水率)을 6%로 유지하면서, 기간은 0, 21, 60, 160 및 215일 동안 온도를 $26.6^{\circ}C(80^{\circ}F)$에 14 시간, $65^{\circ}C(150^{\circ}F)$에서 7시간, $26.6^{\circ}C$로 내리는데 1시간, $65^{\circ}C$로 올리는데 2시간씩으로 순환시켜, 내화처리합판(耐火處理合板)과 무처리합판(無處理合板)의 기계적 성질에 미치는 영향을 조사 비교 하였다. MOE는 내화처리합판(耐火處理合板)과 무처리합판(無處理合板) 사이에 유의성이 없었고, MOR에 있어서 내화처리합판(耐火處理合板)은 무처리합판(無處理合板)에 비하여 15~20% 감소하였고, WML에 있어서 내화처리합판(耐火處理合板)과 무처리합판(無處理合板)사이에 유의성이 있었으며, 두 내화처리합판(耐火處理合板) 사이에도 시간에 따라 유의성이 인정되었다. 따라서 WML은 내화처리합판(耐火處理合板)의 기계적 성질을 구명하는데 좋은 기준이 될 것으로 사료된다.

  • PDF

Wideband Frequency Tunable Metamaterial Absorber Using Switchable Ground Plane (그라운드를 전환하여 주파수를 가변할 수 있는 광대역 메타물질 흡수체)

  • Jeong, Heijun;Lim, Sungjoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.241-246
    • /
    • 2018
  • In this study, we proposed a wideband frequency tunable metamaterial absorber using a switchable ground plane (SGP). We proposed two fire retardant or flame resistant 4 (FR4) substrate structures for the SGP. An SGP is placed at the middle layer, between the top pattern and the bottom ground plane. The SGP can either be made ground or reactive, by switching the PIN diode ON/OFF. As the frequency is determined by the substrate thickness, the frequency can be switched from the SGP. The proposed absorber is demonstrated by full-wave simulations and measurements. When the SGP is turned on, an absorptivity higher than 90% is achieved from 3.5 GHz to 11 GHz. When the SGP is turned off, an absorptivity higher than 90 % is achieved from 1.7 GHz to 5.2 GHz.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF