• Title/Summary/Keyword: Fire safety law

Search Result 159, Processing Time 0.025 seconds

Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus (밀폐계 측정장치를 이용한 물-노말프로판올 계의 인화점)

  • Ha, Dong-Myeong;Choi, Yong-Chan;Lee, Sung-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.140-145
    • /
    • 2002
  • The Flash Point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of chemical materials. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the Water + n-Propanol systems were measured by using Pensky-Martens closed cup tester. The experimental data were compared with the values calculated by the laws of Raoult and van laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

A Study on Revise the Rule of Safety Controllers of Hazardous Substances (위험물 안전관리 제도의 개선에 관한 연구)

  • Park, Kyong-Jin;Shin, Soo-Kyung;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.473-480
    • /
    • 2020
  • In this study, I analyzed problems of safety management system of hazardous substances and proposed improvement measures. By statistics of Korea National Fire Agency it shows that hazardous substances of not less than a designated quantity were 2,180 factorys, 24,732 handling places and 85,218 storing places in 2018. also It has been conformed that Fire accidents break out year after year in factory, etc. so In this study, I analyzed the safety controllers of hazardous substances of the present law and fire statistics. therefore I has been found out the problems that the first, safety controllers' status. the second, There is no laws related design, installation, installation supervision. the third, fire safety inspection. This study will be used a basic data for preventing of extensive hazazardous substances-related accident that is very difficult handling.

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test (중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

A Study on the Prevention and Extinguishment of Fire in Vinyl Temporary Buildings for Agriculture and Fishery (농·어업용 Vinyl 가설건축물의 화재 예방 및 진압에 관한 연구)

  • Bong-Woo Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.599-603
    • /
    • 2023
  • Analyzed in the NFDS, The average number of fires in vinyl temporary buildings is more than 1,000 in annually. And the number of deaths and injuries was around 30 people in every year. According to the National Fire Agency, There are 142,386 vinyl temporary buildings for Agriculture and Fishery, of which 4,720 are residential vinyl temporary buildings in illegally. Model house is subject to regulation in fire-related law. But, even though it's the same temporary building, Vinyl temporary building is not subject to regulation. For this reason, Vinyl temporary buildings are left in the blind spot of fire safety. Therefore, In this study, We propose that amend of Act on installation and management of firefighting systems, make of temporary fire safety controller, develop and apply of alarm system that is connected to a single-alarm smoke dretector, organize and operate volunteer fire brigade of the crop group to prevent and extinguish the fire.

Related Laws and Performance Criteria for Public Service Drones for Disaster Safety (재난안전드론 도입을 위한 법규 및 성능기준 기초연구)

  • Kim, Noh Joon;Lee, Sung Eun;Kim, Hwang Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.150-155
    • /
    • 2016
  • This study is to suggest legislation and criteria for public service drones for disaster safety in order to enhance the research and development of the drones by helping setting right direction of the R&D. Many foreign governments are now conducting research and development on using drones as public service for disaster safety. Although there are also some efforts to using drones for public service in Korea, domestic laws and performance criteria for the drones for the purpose have not prepared yet. To set a right direction of the R&D, the laws and criteria shall be legislated and established immediately and then we can enhance the efforts to develop related technology for the drone. So this study proposed a performance criteria to fit various circumstances and situations by analyzing the aviation law in overseas. We hope this study can help R&D on the public service drones for disaster safety.

A Study to Prevent the Fire in Residential Buildings (주거용 건축물의 화재 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.307-312
    • /
    • 2020
  • This study presents problems and improvement measures for the supply rate of single-alarm detector and fire extinguisher installed in households. Statistics from the NFDS show that 18 percent of all fires and 45 percent of deaths occurred in residential buildings over the past eight years. It was less than 60% that households be equipped rate of basic fire-fighting systems by 2019. In this study, I analyzed the law and statistics of fire to devise a method for fire safety. I proposed that the basic fire-fighting systems is be equipped in households. Like this : First, a free distribution policy for the over 60 years of age and Areas where is fire engine difficult to enter. Second, the policy of adopting safety pay in disaster. Third, the policy of expanding supply through the revision of the Licensed Real Estate Agents Act. Fourth, the policy of self-regulating installation by safety education and set up a data base system. Fifth make a law of household's National Fire Safety Standards.

A Study on the Improvement of the Evacuation in Ward of the General Hospital (종합병원 병동부 피난환경 개선에 관한 연구)

  • Kim, Woo-Seok;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this study is to suggest architectural planning guideline for the improvement of the evacuation environment in a ward. To suggest of guideline, the problem of irrational domestic criteria is searched according to compare National fire code (NFPA101, Life safety code) with Korea building law. This study includes stairs, corridors and exit door etc. but excludes fire facilities. To verify effectiveness of suggested guideline, egress simulation is run that based on databases according to literature survey. The results of this study could be summarized as follow: Suggested guidelines are subdivision(fire partition), evacuation by elevator, secure useful waiting space of elevator hall and smokeproof enclosures, the corridor is divided by fire or smoke barriers corridor from hazardous room, only wheeled items are arranged in corridors of a ward story. The result of computer simulation for suggested guidelines verify that egress time can be decreased 20% or above.

A Study about False Alarm of Automatic Fire Detection System (자동화재 탐지설비의 비화재보 감소방안)

  • Lee, Jong-Hwa;Lee, Chun-Ha;Kim, Shi-Kuk;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building (상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.