DOI QR코드

DOI QR Code

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building

상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구

  • Received : 2016.10.07
  • Accepted : 2016.12.12
  • Published : 2016.12.30

Abstract

Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

Keywords

References

  1. Dong-ll Lim, (2011), "Analysis on the Mig-ration Determinant Factors of 3 Major Cities in Gangwon-Do", Korean Contents Association, 11(1):412-421.
  2. Soon-Goo Lee, Ha-Sung Kong, Sang-Yong Han, (2008), "Fire-countermeasures of Majority-used Buildings", Korean Institute of Fire Science & Engineering, 22(1): 54-60.
  3. Jae-Sung Park, Myong-O Yoon, Jong-Tae Park, (2008), "A Study on Actual Condition and Efficiency of Evacuation Facility in Multiplex Available Premises", Korean Institute of Fire Science & Engineering, 22(2):97-103.
  4. Ji-Soo Ha, Sang-Yeol Yu, Don-Hee Han, Tae-Kwon Kim, (2010), "Fire Characteristic Analysis of Multi-Use Hostels by Using CFAST", Journal of the Korean Society of Marine Engineering, 34(2):339-345. https://doi.org/10.5916/jkosme.2010.34.2.339
  5. Hung-Joo Park, (1999), "Report on Analysis of Significant Factors and Alternative Solutions for Present Korean Multi-Occupancy Building Based on Low-rise Pub Restaurant Building Fire at Inchon", Korean Institute of Fire Science & Engineering, 13(4):61-67.
  6. Jung-Tae Choi, Moo-Eob Ahn, Hee-Cheol Ahn, Young-Mi Choi, Jae-Bong Chung, Jung-Yeol Seo, Ki-Cheol You, Sam-Woo Lee, Suk-Hyun Park, Jun-Hwi Cho, Seong-Whan Kim, Ah-Jin Kim, (2001), Analysis of Victims of the Fire that Broke Out at a Beer Bar in Inchon, The Korean Society of Emergency Medicine, 34(4):511-517.
  7. National Fire Safety Code 502, (2015) of fire department connection.