• Title/Summary/Keyword: Fire pipe

Search Result 183, Processing Time 0.022 seconds

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.

Seismic Analysis of Firefighting Pipe Networks (소방배관 형상에 따른 배관 내진해석)

  • Choi, Ho-Sung;Lee, Jae-Ou
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.149-154
    • /
    • 2019
  • The stability of firefighting pipes is crucial in the event of an earthquake. In Korea, specification-based designs are used in accordance with NFSC. However, engineering performance-based designs are used for buildings that have special requirements. For firefighting pipes, tree type pipe networks are usually utilized in buildings; however, they are characterized by several limitations. Hence, grid type and loop type networks are being utilized lately. Earthquake-resistant designs for firefighting pipes in Korea utilize NFPA 13 as the cookbook. Nevertheless, an engineering analysis is required to verify its reliability. The NFPA 13 standard used in Korea is a design method for engineers who lack earthquake engineering analysis knowledge of pipes and adapt ASCE and ASME guidelines. Earthquake resistant designs in Korea review braces only. Hence, various analyses under load conditions, such as the internal pressure of a pipe, force exerted by a continuous load, and an earthquake, are required to ensure reliability. An engineering earthquake-resistance analysis showed that tree type pipe networks are less stable than grid and loop type pipe networks. A comparison of earthquake-resistance analysis based on stress and strain revealed that strain analysis exhibited a conservative result value in the range of over-stress. Therefore, for the earthquake-resistance analysis of pipes, it is rational that engineers perform analysis to achieve the required standards through engineering analysis rather than uniform calculations, which should also be analyzed considering various analysis conditions.

Analysis of the Impact of Fire and Explosion Accidents due to LNG Leaks in the LNG Re-gasification Process (LNG 재기화 공정에서 LNG 누출에 따른 화재 및 폭발사고의 피해영향 분석)

  • Lee, Yoon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.825-833
    • /
    • 2018
  • In this study, one calculated the range of damage to the combustion characteristics according to the composition of LNG and the size of leaking holes, and analyzed the damage effect in case of leakage accidents caused by pipe damage in the re-gasification process for the LNG supply system. In order to confirm the combustion characteristics according to LNG composition, there was no significant difference in the result of risk analysis by LNG-producing areas. However, the higher the methane content of the components, the lower the risk of flash fire, hazardous areas of overpressure due to explosion, and thermal radiation damage caused by jet fire. In addition, one investigated the effect of leakage, holes, and ruptures on the risk range and explosions according to the size of the pipe-leakage hole. Also, the influence of overpressure and the range of damage from radiant heat could be predicted. One confirmed the effect of LNG composition and pipe-leakage size on fire and explosion.

A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings (건축물에 설치되는 소방용 배관의 내진장치에 관한 연구)

  • Lim, Geon-Tae;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • This study is a technology related to a seismic protection device for a fire pipe for installation in a building such as an apartment or a building. The fire pipe is fixed to the base panel by fastening bolts so as to flow left and right. The present invention relates to an earthquake-resistant apparatus for a fire-extinguishing piping, which is capable of minimizing damages caused by an earthquake in order to prevent damages and breakage of a fire-extinguishing pipe by mitigating earthquakes, vibrations, It is connected to an insert plate embedded in concrete or ceiling hanger bolts formed at regular intervals on the ceiling to keep the piping constant from the ceiling and to keep the horizontal condition of the piping always constant so that the piping relaxes or sags And to effectively prevent damage to the piping. The can get.

Numerical Analysis of Unsteady Heat Transfer for Location Selection of CPVC Piping (CPVC 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석)

  • Choi, Myoung-Young;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.33-39
    • /
    • 2015
  • In this paper, a numerical experiment was conducted to find out the optimal location of electrical heat trace for anti-freeze of water inside the CPVC pipe for fire protection. The unsteady incompressible Navier-Stokes equations coupled with energy equation were solved. Since the conduction equation of pipe was coupled with the natural convection of water, the analysis of conjugate heat transfer was conducted. A commercial code (ANSYS-FLUENT) based on SIMPLE-type algorithm was used for investigating the unsteady flows and temperature distributions in water region. From the present numerical experiment, it has been found that the vector field of water inside the PVC pipe is opposite to the case of steel because of the huge difference of material properties of the two pipes. Furthermore, it was found that the lowest part of the pipe was an optimal position for electrical heat trace since the minimum water temperature of the case was higher than those of the other cases.

An experimental investigation on the errect of air entrainment (공기유입이 화재강도에 미치는 영향에 대한 실험적인 연구)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.21
    • /
    • pp.5-12
    • /
    • 1996
  • An experimental investigation has been made with the objcetive of studying the effects of air entrainment of fire strength. A rich jet flame is considered as an fire, and fire, and the air entrainment is controlled by introducing the tone excitation which is generated by means of a loudspeaker-driven cavity. The excitation frequency is chosen for the resonant frequency identified as a pipe resonance due to acoustic excitation. As the excitation intensity increases, the amplitude of oscillating velocity for inducing air entrainment is increased, the flame height decreased and the structure of diffusion flame gradually transformed to that of premixed flame.

  • PDF

Development of an Anti-Freezing Heating Cable Temperature Controller and Its Power Saving Effects Analysis (동파방지 발열선용 온도제어기 개발 및 전기에너지 절감 효과 분석)

  • Lee, Kihong;Lee, Jaejin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.101-106
    • /
    • 2014
  • Although anti-freezing heating cable has been widely installed in most residential boiler pipe, there were excessive energy consumption and fire risk due to inadequate temperature control. In this paper, a new energy saving fire risk-free controller was developed by using microprocessing operation which include detection of not only boiler room temperature but also pipe surface one. Its actual effect has been verified to save more than a half of the energy consumption comparing to conventional controller through temperature and humidity chamber experiment.

Drag Reduction of Pipe Wall For Fluid Flow due to Injected Polymer Solution - II. Local Drag Reduction in Turbulent Flow- (고분자용액에 의한 유체수송관벽의 저항감소 -II. 난류흐름에서 국소저항감소-)

  • 추낙준;유경옥
    • Fire Science and Engineering
    • /
    • v.5 no.2
    • /
    • pp.11-20
    • /
    • 1991
  • Dilute polymer solutions were injected into turbulent pipe flow of a Newtonian fluid. The local drag reduction for injection of polymer solution at the pipe wall was larger than that at centerline. From the above result we may conclude that the polymer additives were found to influence the flow in the neighborhood of the wall. The effects of the injection apparatus on the local drag reduction are small compared to the drag-reducing effects. The extent of drag reduction increased with polymer concentration and injection flow rate, and the maximum drag reduction obtained were 47% for Polyox Coagulant and 35% for Separan AP-273. In respect to polymer degradation, the polyacrylamide showed better shear stability than the polyethyleneoxide and thus the former expected to have a sharper molecular weight distribution.

  • PDF

A Study on the Pressure Drops of T-Branch Pipes (분기배관의 압력강하에 관한 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Kwon, Soon-Kwan;Kim, Dong-Hyun;Min, Kyung-Tak;Kim, Byoung-Gon;Lee, Sung-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.272-277
    • /
    • 2008
  • This study is performed for propose that exactly equivalent length of TBP in the applied at water-based fire protection system. For predict the measuring position of equivalent length, we determined the measuring position using the FVM about pressure drop of TBP. For the reckon of the exact about measured value we compared with the result of FVM and we knew the similar value each other. Using the results we proposed the friction loss measuring position that inlet of main dirction is 20 times of appellation diameter in main pipe, outlet of main dirction is 10 times of appellation diameter in main pipe and outlet of branched direction is 20 times of appellation diameter.