• Title/Summary/Keyword: Fire monitoring

Search Result 401, Processing Time 0.027 seconds

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Disaster Prediction, Monitoring, and Response Using Remote Sensing and GIS (원격탐사와 GIS를 이용한 재난 예측, 감시 및 대응)

  • Kim, Junwoo;Kim, Duk-jin;Sohn, Hong-Gyoo;Choi, Jinmu;Im, Jungho
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.661-667
    • /
    • 2022
  • As remote sensing and GIS have been considered to be essential technologies for disasters information production, researches on developing methods for analyzing spatial data, and developing new technologies for such purposes, have been actively conducted. Especially, it is assumed that the use of remote sensing and GIS for disaster management will continue to develop thanks to the launch of recent satellite constellations, the use of various remote sensing platforms, the improvement of acquired data processing and storage capacity, and the advancement of artificial intelligence technology. This spatial issue presents 10 research papers regarding ship detection, building information extraction, ocean environment monitoring, flood monitoring, forest fire detection, and decision making using remote sensing and GIS technologies, which can be applied at the disaster prediction, monitoring and response stages. It is anticipated that the papers published in this special issue could be a valuable reference for developing technologies for disaster management and academic advancement of related fields.

A Study on the Seismic Resistance Design of Sway Brace Device using Internet of Things (IoT를 활용한 흔들림 방지 버팀대의 내진설계에 관한 연구)

  • Thak, Sung-In;Yu, Bong-Geun;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.58-62
    • /
    • 2017
  • There is a growing need for seismic resistance design. But it is controversial that standards of sway brace device in non-structural elements for buildings like pump waterway is vary widely. Therefore, in this study to get a valid range of sway brace device in seismic resistance design, using load test of sway brace device. As a result, load of safe range from 0 to 18.5 kN and under 29.4 kN, no structural fault of sway brace device. And using internet of things get a data of seismic resistance design from sensor node like accelerometer, GPS, tilt sensor and temperature sensor through steps of sampling and prediction. These results will be acceptable for monitoring system for seismic resistance in non-structural elements.

Vegetation Change after A Forest Fire in a Rural Japanese Red Pine Forest and Applications of Effective Microorganism (농촌 소나무림에서 산불에 의한 식생변화와 유용미생물의 적용)

  • Yeo, Ji Sean;Kim, Kee Dae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.4
    • /
    • pp.46-56
    • /
    • 2008
  • This study examined the natural restoration of vegetation through monitoring of the development of a vegetation community from 2006 through 2007 after a forest fire. Approximately 5,000 $m^2$ in a forest near Topyeon-ri, Kangnae-myeon, Chungcheongbuk-do with Japanese red pine (Pinus densiflora) forest and its floor vegetation had been completely burned by a fire in April 2005. This area and another nearby Japanese red pine forest were selected as the experiment site and the control site, respectively. Vegetation survey was conducted at the experiment site and the control site. A seed bank experiment was carried out in the greenhouse to examine underground vegetation. Effective microorganism(EM) was applied to the seed bank experiment to estimate its effects on the direction of ecological succession. According to the results, a total of 36 plant species including shrub and herbaceous species were discovered in the experiment site. Quercus serrata, Lespedeza cyrtobotrya, and Castanea crenata, Rubus crataegifolius, Oplismenus undulatifolius, and Carex lanceolata were among the most abundant species. Biomass in the experiment site reached 2.4 times biomass than those in the control site, indicating the productivities of shrub and herbaceous layers are better in the experiment site. According to the result of the soil seed bank experiment of the experiment site, a total of 182 plants of 14 species were recorded. In addition, a total of 13 plants of 2 species were found from soil seed bank of the experiment site applied by EM. If EM is applied to the burned site, it will control the budding of herbaceous plants, creating the gap between herbaceous plants. This loss of competition is expected to help the restoration of trees in the burned area.

Above- and below-ground vegetative responses to prescribed fire regimes in a Chesapeake Bay tidal brackish marsh

  • Leonard, Cheryl A.;Ahn, Chang-Woo;Birch, Dixie
    • Journal of Ecology and Environment
    • /
    • v.33 no.4
    • /
    • pp.351-361
    • /
    • 2010
  • The primary purposes for using fire are to enhance marsh vegetation to support waterfowl, and to manage invasive plant species. The study was conducted for two consecutive years in 2004 and 2005, investigating the effects of prescribed fire regimes on vegetation biomass in tidal brackish marsh areas of the Blackwater National Wildlife Refuge located on the eastern shore of Maryland, USA, that are under relatively similar environmental conditions. Four different burn regimes (i.e., annual burn, 3-5 year burn, 7-10 year burn, and no burn) were applied in the study. Above- and below-ground vegetation biomass samples as affected by the different burn regimes were harvested in each year for five plant species native to the marsh; Distichlis spicata, Spartina alterniflora, Schoenoplectus americanus, Spartina cynosuroides and Spartina patens. No significant difference was found either in total above-ground biomass or in above-ground biomass by species between burn regimes in 2004. However, more total above-ground biomass was produced in annual burn regime in 2005 than in the other burn regimes. There were no consistent effects of burning on vegetative biomass production by species, but it seemed D. spicata was somewhat benefited by prescribed burning for its biomass production. Moreover, the stem density for D. spicata under annual burn regime was significantly higher than that in the other burn regimes, showing some positive effects of burning on vegetation. The below-ground biomass was significantly greater in 2004 than in 2005, yet with no significant difference between burn regimes in either year. A longer-term monitoring is strongly recommended.

The signal processing algorithm of the Missile Flight Test Launch Control System (비행시험 발사통제 시스템의 신호처리 알고리즘)

  • Oh, Jino
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1965-1972
    • /
    • 2015
  • The Missile Flight Test Launch Control System is to operate in conjunction with the Fire Control System during flight test to guided weapons. Also, this is a system for the test control and situation monitoring depending on the type of guided weapons and testing purposes. Message structure, communication protocols, such as data types for interworking with the fire control system and the Missile Flight Test Launch Control System are defined in the Launch Control ICD(Interface Control Document). ICD are composed differently of each guided weapons system and each test object. Previously, in order to interwork with the Fire Control System, the interlocking software was developed, which had a variety of problems. Therefore, we developed a new parsing algorithm in order to recognize the variety of Launch Control ICD and verified that the algorithm operates normally by checking transmitting and receiving various message in conjunction with the fire control system.

Synchronized sensing for wireless monitoring of large structures

  • Kim, Robin E.;Li, Jian;Spencer, Billie F. Jr;Nagayama, Tomonori;Mechitov, Kirill A.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.885-909
    • /
    • 2016
  • Advances in low-cost wireless sensing have made instrumentation of large civil infrastructure systems with dense arrays of wireless sensors possible. A critical issue with regard to effective use of the information harvested from these sensors is synchronized sensing. Although a number of synchronization methods have been developed, most provide only clock synchronization. Synchronized sensing requires not only clock synchronization among wireless nodes, but also synchronization of the data. Existing synchronization protocols are generally limited to networks of modest size in which all sensor nodes are within a limited distance from a central base station. The scale of civil infrastructure is often too large to be covered by a single wireless sensor network. Multiple independent networks have been installed, and post-facto synchronization schemes have been developed and applied with some success. In this paper, we present a new approach to achieving synchronized sensing among multiple networks using the Pulse-Per-Second signals from low-cost GPS receivers. The method is implemented and verified on the Imote2 sensor platform using TinyOS to achieve $50{\mu}s$ synchronization accuracy of the measured data for multiple networks. These results demonstrate that the proposed approach is highly-scalable, realizing precise synchronized sensing that is necessary for effective structural health monitoring.

A study on Installation of Facility Monitoring System in Computer Room's (전산실 기반설비감시시스템 구축에 관한 연구)

  • Choi, Woo-hyoung;Kim, Chang-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.159-161
    • /
    • 2013
  • Surveillance system that can respond quickly in case of failure to detect various disorders that can occur for a temperature chamber, and fire extinguishing equipment, such as UPS, communication room, and computer room of enterprises and institutions operating in infrastructure, and to systematically study. Major telecommunications equipment and computational facilities to manage, operating in an environment of air conditioners work status, distribution panel and the UPS status and fault status, rapid notification system in case of fire is needed. By identifying the status and problems of disability surveillance on the periphery of the existing computer room's infrastructure management guidelines presented in the next future Conception and systematic surveillance system for staff to refer to when designing considerations associated with data center monitoring system the necessity of the various studies are presented.

  • PDF

A Design and Implementation of Digital Vessel Context Diagnosis System Based on Context Aware (상황 인식 기반 해양 디지털 선박 상황 진단 시스템 구현 및 설계)

  • Song, Byoung-Ho;Choi, Myeong-Soo;Kwon, Jang-Woo;Lee, Sung-Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.6B
    • /
    • pp.859-866
    • /
    • 2010
  • Digital vessels can occur large a disaster at sea because vessels in fire and collision in case of certain unforeseen circumstances. In this paper, We propose digital vessel context monitoring system through risk analysis. We propose environment information analysis system using wireless sensor that have to acquire marine environment and context of marine digital vessel. For conducting simulation, we chose 300 data sets to train the neural network. As a result, we obtained about 96% accuracy for fire risk context and we obtained 88.7% accuracy for body of vessel risk context. To improve the accuracy of the system, we implement a FEC (Forward Error Correction) block. We implemented digital vessel context monitoring system that transmitted to diagnosis result in CDMA.